Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 23
Filter
Add more filters










Publication year range
1.
Surf Topogr ; 4(1): 013002, 2016 Mar.
Article in English | MEDLINE | ID: mdl-27182440

ABSTRACT

The application of surface topography measurement methods to the field of firearm and toolmark analysis is fairly new. The field has been boosted by the development of a number of competing optical methods, which has improved the speed and accuracy of surface topography acquisitions. We describe here some of these measurement methods as well as several analytical methods for assessing similarities and differences among pairs of surfaces. We also provide a few examples of research results to identify cartridge cases originating from the same firearm or tool marks produced by the same tool. Physical standards and issues of traceability are also discussed.

2.
J Res Natl Inst Stand Technol ; 119: 644-73, 2014.
Article in English | MEDLINE | ID: mdl-26601051

ABSTRACT

In response to the guidelines issued by the American Society of Crime Laboratory Directors/Laboratory Accreditation Board (ASCLD/LAB-International) to establish traceability and quality assurance in U.S. crime laboratories, NIST and the ATF initiated a joint project, entitled the National Ballistics Imaging Comparison (NBIC). The NBIC project aims to establish a national traceability and quality system for ballistics identifications in crime laboratories utilizing ATF's National Integrated Ballistics Information Network (NIBIN). The original NBIC was completed in 2010. In the second NBIC, NIST Standard Reference Material (SRM) 2461 Cartridge Cases were used as reference standards, and 14 experts from 11 U.S. crime laboratories each performed 17 image acquisitions and correlations of the SRM cartridge cases over the course of about half a year. Resulting correlation scores were collected by NIST for statistical analyses, from which control charts and control limits were developed for the proposed quality system and for promoting future assessments and accreditations for firearm evidence in U.S. forensic laboratories in accordance with the ISO 17025 Standard.

3.
Forensic Sci Int ; 216(1-3): 168-82, 2012 Mar 10.
Article in English | MEDLINE | ID: mdl-22014973

ABSTRACT

In response to the guidelines issued by the American Society of Crime Laboratory Directors/Laboratory Accreditation Board (ASCLD/LAB-International) to establish traceability and quality assurance in U.S. crime laboratories, a NIST/ATF joint project entitled National Ballistics Imaging Comparison (NBIC) was initialized in 2008. The NBIC project aims to establish a National Traceability and Quality System for ballistics identifications in crime laboratories within the National Integrated Ballistics Information Network (NIBIN) of the U.S. NIST Standard Reference Material (SRM) 2460 bullets and 2461 cartridge cases are used as reference standards. 19 ballistics examiners from 13 U.S. crime laboratories participated in this project. They each performed 24 periodic image acquisitions and correlations of the SRM bullets and cartridge cases over the course of a year, but one examiner only participated in Phase 1 tests of SRM cartridge case. The correlation scores were collected by NIST for statistical analyses, from which control charts and control limits were developed for the proposed Quality System and for promoting future assessments and accreditations for firearm evidence in U.S. forensic laboratories in accordance with the ISO 17025 Standard.

4.
J Biomed Mater Res A ; 92(2): 604-14, 2010 Feb.
Article in English | MEDLINE | ID: mdl-19235219

ABSTRACT

Many methods exist in the literature to modify surfaces with extracellular matrix (ECM) proteins prior to cell seeding. However, there are few studies that systematically characterize and compare surface properties and cell response results among modification methods that use different bonding mechanisms. In this work, we compare cell response and physical characterization results from fibronectin or laminin attached to polydimethylsiloxane (PDMS) elastomer surfaces by physical adsorption, chemisorption, and covalent attachment to determine the best method to modify a deformable surface. We evaluate modification methods based on completeness and uniformity of coverage, surface roughness, and hydrophilicity of attached ECM protein. Smooth muscle cell adhesion, proliferation, morphology, and phenotype were also evaluated. We found that chemisorption methods resulted in higher amounts of protein attachment than physical adsorption and covalent bonding of the ECM proteins. Cell response to protein-modified surfaces was similar with respect to cell adhesion, area, aspect ratio, and phenotype. When all the data are considered, the chemisorption methods, most notably silane_70, provide the best surface properties and highest cell proliferation.


Subject(s)
Biocompatible Materials/chemistry , Dimethylpolysiloxanes/chemistry , Myocytes, Smooth Muscle/physiology , Adsorption , Animals , Cell Adhesion , Cell Proliferation/drug effects , Cells, Cultured , Extracellular Matrix/physiology , Extracellular Matrix Proteins/metabolism , Genetic Markers , Glutaral/chemistry , Immunohistochemistry , Microscopy, Confocal , Microscopy, Electron, Scanning , Microscopy, Fluorescence , Muscle Contraction/physiology , Oxidation-Reduction , Plasma/chemistry , Rats , Reverse Transcriptase Polymerase Chain Reaction , Spectroscopy, Fourier Transform Infrared
5.
Appl Opt ; 40(13): 2159-68, 2001 May 01.
Article in English | MEDLINE | ID: mdl-18357223

ABSTRACT

Comparisons are made between calculated and measured angle-resolved light-scattering distributions from clear dielectric isotropic epoxy coatings over a range of rms roughness conditions, resulting in strongly specular scattering to diffuse scattering characteristics. Calculated distributions are derived from topography measurements performed with interferometric microscopes. Two methods of calculation are used. One determines the intensity of scattered light waves with a phase integral in the Kirchhoff approximation. The other is based on the reflection of light rays by locally flat surfaces. The angle-resolved scattering distributions for the coatings are measured with the spectral trifunction automated reference reflectometer (STARR) developed by the National Institute of Standards and Technology. Comparisons between measured and calculated results are shown for three surfaces with rms roughness values of approximately 3, 150, and 800 nm for an angle of incidence of 20 degrees .

6.
Appl Opt ; 39(25): 4473-85, 2000 Sep 01.
Article in English | MEDLINE | ID: mdl-18350034

ABSTRACT

The angular distributions of light scattered by gold-coated and aluminum-coated gratings with amplitudes of approximately 90 nm and periods of 6.67 microm were measured and calculated for light incident from a He-Ne laser at an angle of 6 degrees. Experimental results are compared with predictions of Beckmann's scalar theory and Rayleigh's vector theory. The measured scattering pattern has a background of scattered light due mainly to residual surface roughness. Also the power in the higher-order peaks is larger by several orders of magnitude than the computed one, which can be attributed mainly to the low-order contributions of the harmonics in the profile.

7.
Appl Opt ; 34(7): 1269-77, 1995 Mar 01.
Article in English | MEDLINE | ID: mdl-21037658

ABSTRACT

Sinusoidal surfaces can be used as material standards to help calibrate instruments that measure the angular distribution of the intensity of light scattered by arbitrary surfaces, because the power in the diffraction peaks varies over several orders of magnitude. The calculated power in the higher-order diffraction peaks from sinusoidal surfaces expressed in terms of Bessel functions is much smaller than the values determined from angular distributions that are measured or computed from measured profiles, both of which are determined mainly by the harmonic contents of the profile. The finite size of the illuminated area, represented by an illumination window, gives rise to a background that is much larger than the calculated power in the higher-order peaks. For a rectangular window of a size equal to an even number of periods of the sinusoid, a computation of the power distribution produces minima at or near the location of the diffraction angles for higher-order diffraction angles.

8.
J Res Natl Inst Stand Technol ; 100(5): 543-561, 1995.
Article in English | MEDLINE | ID: mdl-29151760

ABSTRACT

National and international comparisons in Rockwell hardness tests show significant differences. Uncertainties in the geometry of the Rockwell diamond indenters are largely responsible for these differences. By using a stylus instrument, with a series of calibration and check standards, and calibration and uncertainty calculation procedures, we have calibrated the microform geometric parameters of Rockwell diamond indenters. These calibrations are traceable to fundamental standards. The expanded uncertainties (95 % level of confidence) are ±0.3 µm for the least-squares radius; ±0.01° for the cone angle; and ±0.025° for the holder axis alignment calibrations. Under ISO and NIST guidelines for expressing measurement uncertainties, the calibration and uncertainty calculation procedure, error sources, and uncertainty components are described, and the expanded uncertainties are calculated. The instrumentation and calibration procedure also allows the measurement of profile deviation from the least-squares radius and cone flank straightness. The surface roughness and the shape of the spherical tip of the diamond indenter can also be explored and quantified. Our calibration approach makes it possible to quantify the uncertainty, uniformity, and reproducibility of Rockwell diamond indenter microform geometry, as well as to unify the Rockwell hardness standards, through fundamental measurements rather than by performance comparisons.

9.
J Res Natl Inst Stand Technol ; 99(2): 191-199, 1994.
Article in English | MEDLINE | ID: mdl-37404711

ABSTRACT

Standard Reference Material 484 is an artifact for calibrating the magnification scale of a Scanning Electron Microscope (SEM) within the range of 1000 × to 20000 ×. Seven issues, SRM-484, and SRM-484a to SRM-484f, have been certified between 1977 and 1992. This publication documents the instrumentation, measurement procedures and determination of uncertainty for SRM-484 and illustrates with data from issues 484e and 484f.

10.
Appl Opt ; 32(1): 67-76, 1993 Jan 01.
Article in English | MEDLINE | ID: mdl-20802663

ABSTRACT

The relationship between the height autocorrelation function of a one-dimensionally rough surface and the Fourier transform of the intensity distribution of the light scattered by that surface is tested experimentally. The theory is derived by using the Fraunhofer approximation, without recourse to the inconsistent Kirchhoff boundary conditions. In spite of the limitations imposed by the approximations used, the results obtained from optical data agree well with those obtained from stylus data, even for an autocorrelation length as small as the optical wavelength. However, this method should be limited to surfaces with rms roughness smaller than approximately 0.14 times the wavelength of light.

11.
Appl Opt ; 32(19): 3401-8, 1993 Jul 01.
Article in English | MEDLINE | ID: mdl-20829957

ABSTRACT

In this paper we summarize a number of previous experiments on the measurement of the roughness of metallic surfaces by light scattering. We identify several regimes that permit measurement of different surface parameters and functions, and we establish approximate limits for each regime. Using a straightforward criterion, we calculate that the smooth-surface regime, in which the angular distribution of scattered light is closely related to the power spectral density of the roughness, ranges over 0 < σ/λ ≲ 0.05, where σ is the rms roughness and λ is the opitcal wavelength. Above that the surfaceautocorrelation function may be calculated from a Fourier transform of the angular distribution over 0 < σ/λ ≲ 0.14. Then comes the specular regime where the specular beam can still be identified andmeasured over 0 < σ/λ ≲ 0.3. For all these regimes and for rougher surfaces too, the rms width of thescatter distribution is proportional to the rms slope of the surface.

12.
Ann Chir ; 46(1): 24-8, 1992.
Article in French | MEDLINE | ID: mdl-1550315

ABSTRACT

Five cases of hepatic tumor deemed unresectable by conventional techniques are presented to illustrate the potential benefit offered by complete hepatic vascular exclusion (Pringle maneuver associated with inferior vena cava clamping below and above the liver). The most extensive and difficult liver resections may be achieved, with possible venous reconstruction, if the clamping period is not interrupted. Hepatic vascular exclusion may exceed one hour, up to 85 minutes in this series, with a good liver tolerance, in the absence of preoperative liver dysfunction. The advantages and disadvantages of the ex situ extracorporeal liver resections performed under similar circumstances are discussed. The authors consider that the role of ex situ liver procedures should be very limited.


Subject(s)
Hemangioma/surgery , Hepatectomy/methods , Liver Neoplasms/surgery , Adult , Colonic Neoplasms/pathology , Female , Hemangioma/diagnostic imaging , Humans , Liver Neoplasms/diagnostic imaging , Liver Neoplasms/secondary , Magnetic Resonance Imaging , Male , Malignant Carcinoid Syndrome/pathology , Middle Aged , Postoperative Complications , Radiography , Reoperation
13.
Ann Radiol (Paris) ; 35(4): 244-8, 1992.
Article in French | MEDLINE | ID: mdl-1288396

ABSTRACT

Five cases of hepatic tumor deemed unresectable by conventional techniques are presented to illustrate the potential benefit offered by complete hepatic vascular exclusion (Pringle maneuver associated with inferior vena cava clamping below and above the liver). The most extensive and difficult liver resections may be achieved, with possible venous reconstruction, if the clamping period is not interrupted. Hepatic vascular exclusion may exceed one hour, up to 85 minutes in this series, with a good liver tolerance, in the absence of preoperative liver dysfunction. The advantages and disadvantages of the ex situ extracorporeal liver resections performed under similar circumstances are discussed. The authors consider that the role of ex situ liver procedures should be very limited.


Subject(s)
Hemangioma/surgery , Hepatectomy/methods , Liver Neoplasms/surgery , Adult , Colonic Neoplasms/pathology , Female , Hemangioma/diagnostic imaging , Humans , Liver Neoplasms/diagnostic imaging , Liver Neoplasms/secondary , Magnetic Resonance Imaging , Male , Middle Aged , Radiography
14.
Eur Surg Res ; 24(4): 243-8, 1992.
Article in English | MEDLINE | ID: mdl-1380460

ABSTRACT

We assessed FK506 (FK) and rapamycin (RPM) in a heterotopic abdominal rat heart transplant model using a major histocompatibility mismatch (DA to LEW). The end point of our study was histologic grading of rejection (Billingham and working formulation) at 1 week. Two doses of FK (2.0 and 8.0 mg/kg p.o., q.d.) and RPM (1.5 and 6.0 mg/kg i.p., q.d.) were compared to allografts without and with ciclosporin (12.5 mg/kg p.o., q.d.) treatment. Results show: (1) weak heartbeat and full rejection on day 5 in all untreated allografts; (2) weak heartbeat and high degree of rejection in groups receiving low doses of FK and RPM; (3) strong heartbeat and mild rejection in both high FK and RPM dose groups comparable to the results of the hearts treated with ciclosporin; (4) 1 animal in each high FK and RPM dose group showed possible signs of toxicity, and (5) the strength of the heartbeat was not a reliable indicator of the efficacy of an immunosuppressive drug. We conclude that even in a major histocompatibility mismatch model at the time of the strongest immune response (1 week), all three tested drugs can reduce the degree of rejection from severe (untreated allografts) to mild if given in an adequate dosage.


Subject(s)
Immunosuppressive Agents/therapeutic use , Polyenes/therapeutic use , Tacrolimus/therapeutic use , Animals , Cyclosporins/therapeutic use , Graft Rejection/drug effects , Heart Transplantation , Polyenes/adverse effects , Rats , Rats, Inbred Strains , Sirolimus , Tacrolimus/adverse effects , Transplantation, Heterotopic , Transplantation, Homologous
15.
Thorac Cardiovasc Surg ; 39 Suppl 3: 217-20, 1991 Dec.
Article in English | MEDLINE | ID: mdl-1803633

ABSTRACT

Nuclear magnetic resonance (NMR) criteria of early cardiac rejection are similar to those seen in myocardial ischemia, that is, a reduction of high energy phosphatases (Pc; ATP) and an increase of inorganic phosphates (Pi). Our aim was to assess in vivo changes of phosphorous spectroscopy (31P) induced by cardiac rejection and myocardial ischemia in the same animal. Heterotopic heart isografts (n = 5) and untreated allografts (n = 5) were examined at seven days on a two tesla wide-bore magnet with a surface coil. Subtotal global ischemia was produced for sequential NMR measurements, followed by heart excision for histological rejection grading (Billingham). Results 1. Isograft served as controls and showed normal energy-rich phosphate compounds and pH. 2. Rejecting (moderate to severe) allografts showed a decrease of Pc/Pi and beta-ATP/Pi ratio compared with isografts. However no significant pH drop could be detected. 3. Induced ischemia was confirmed by marked ECG-ST elevation and showed a significant early global myocardial acidosis (pH less than 6.9) particularly in severe prolonged ischemia (p less than 0.05). 4. Using 31P NMR techniques, ischemically induced changes were similar in isografts and allografts with a trend towards a more pronounced extent in the latter groups. In conclusion, magnetic resonance spectroscopy (31P and pH) allows in vivo differentiation between cardiac rejection and acute myocardial ischemia.


Subject(s)
Coronary Disease/diagnosis , Graft Rejection , Heart Transplantation , Magnetic Resonance Imaging , Acute Disease , Animals , Diagnosis, Differential , Myocardial Infarction/diagnosis , Rats
16.
Thorac Cardiovasc Surg ; 39(4): 224-7, 1991 Aug.
Article in English | MEDLINE | ID: mdl-1948972

ABSTRACT

Eighty-three patients underwent pulmonary metastatectomy as part of a combined modality approach between 1. 1. 1972 and 31. 12. 1988 and 80 were followed up until 1. 1. 1990 or until death, with an average follow-up of 110 months. The estimated 5-, 10-, and 15-year survival rate was 38%, 32%, and 22% respectively. Recurrent pulmonary metastases were observed in 60% of the patients during follow-up with an estimated 24 months relapse-free survival rate of 50%. An additional 20% of the patients developed extrapulmonary recurrent tumor manifestation without evidence of pulmonary disease. One of five patients remained tumor free up to 207 months (an average of 87 months) after the initial pulmonary metastatectomy. A multivariate analysis identified completeness of tumor removal, the type of primary tumor, and a difference in histology between primary and metastatic neoplasm as three independent prognostic factors with significant impact on overall survival, the completeness of tumor removal being the most important one. Disease-free long-term survival for patients with pulmonary metastases treated by surgery and chemotherapy is related to completeness of tumor removal and the type of primary tumor.


Subject(s)
Lung Neoplasms/secondary , Combined Modality Therapy , Follow-Up Studies , Humans , Lung Neoplasms/drug therapy , Lung Neoplasms/mortality , Lung Neoplasms/surgery , Middle Aged , Neoplasm Recurrence, Local , Survival Rate
17.
Appl Opt ; 30(1): 42-50, 1991 Jan 01.
Article in English | MEDLINE | ID: mdl-20581945

ABSTRACT

This paper describes experimental work to improve the lateral resolution of stylus instruments. Our efforts involve (1) use of a fine stylus, (2) low stylus load, (3) high magnification in the lateral direction, and (4) specimens with fine surface structure by which the lateral resolution of stylus instruments could be detected. By using styli with tip widths between 0.05 and 0.15-microm, a stylus load of 0.6-1.2 x 10(-6)-N (0.06-0.12-mgf), and a piezostage for lateral displacement, we detected 0.05-0.15-microm lateral resolution on the surfaces of different kinds of specimens. To get a high lateral resolution, the most important consideration is a fine stylus with small tip size.

18.
Appl Opt ; 30(22): 3221-7, 1991 Aug 01.
Article in English | MEDLINE | ID: mdl-20706378

ABSTRACT

Angle-resolved light scattering (ARLS) is used to estimate the root-mean-square (rms) slopes of rough surfaces having a well-defined lay, and the effect on slope measurements caused by changing the angles of incidence and scattering is investigated. The ARLS patterns are taken with the Detector Array for Laser Light Angular Scattering (Dallas) research instrument, and the rms slopes are obtained from the angular widths of these patterns. In general, it was found that the angular width, and thus the estimated rms slope, is surprisingly insensitive to relatively large changes in both the incident and scattering angles of light. These results are independent of surface material and are valid for both sinusoidal and random rough surfaces with lay. The principles, experiments, analyses, and conclusions involved in using ARLS to estimate rms surface slopes are described.

19.
Appl Opt ; 30(30): 4439-47, 1991 Oct 20.
Article in English | MEDLINE | ID: mdl-20717222

ABSTRACT

The application of angle-resolved light scattering (ARLS) to the measurement of the surface roughness of glossy coatings on paper was investigated. To this end, ARLS patterns were measured for laser light scattered from several glossy paper samples, and these patterns were compared with those calculated using a theoretical model based on plane-wave scattering from an isotropic rough surface. Mechanical stylus profilometry data for the rms roughnesses and the autocorrelation functions of the coatings were used as input to calculate the patterns. For all the paper samples measured, as well as for all the incidence angles used, there was good agreement between the experimental and the calculated patterns when all the rms roughnesses measured by profilometry were reduced by 30%. The indication from these experiments is that ARLS may be used to determine the roughness parameters of the coatings. As a check on these results, measurements were also performed with a commercial optical surface probe; these data agreed well with both the ARLS and the stylus profilometry results.

20.
J Res Natl Inst Stand Technol ; 96(3): 271-289, 1991.
Article in English | MEDLINE | ID: mdl-28184115

ABSTRACT

In the quality control of engineering surfaces, we aim to understand and maintain a good relationship between the manufacturing process and surface function. This is achieved by controlling the surface texture. The control process involves: 1) learning the functional parameters and their control values through controlled experiments or through a long history of production and use; 2) maintaining high accuracy and reproducibility with measurements not only of roughness calibration specimens but also of real engineering parts. In this paper, the characteristics, utilizations, and limitations of different classes of precision roughness calibration specimens are described. A measuring procedure of engineering surfaces, based on the calibration procedure of roughness specimens at NIST, is proposed. This procedure involves utilization of check specimens with waveform, wavelength, and other roughness parameters similar to functioning engineering surfaces. These check specimens would be certified under standardized reference measuring conditions, or by a reference instrument, and could be used for overall checking of the measuring procedure and for maintaining accuracy and agreement in engineering surface measurement. The concept of "surface texture design" is also suggested, which involves designing the engineering surface texture, the manufacturing process, and the quality control procedure to meet the optimal functional needs.

SELECTION OF CITATIONS
SEARCH DETAIL
...