1.
Sci Rep ; 14(1): 10409, 2024 05 06.
Article in English | MEDLINE | ID: mdl-38710782

ABSTRACT

In transcatheter aortic valve implantation (TAVI), final device position may be affected by device interaction with the whole aortic landing zone (LZ) extending to ascending aorta. We investigated the impact of aortic LZ curvature and angulation on TAVI implantation depth, comparing short-frame balloon-expanding (BE) and long-frame self-expanding (SE) devices. Patients (n = 202) treated with BE or SE devices were matched based on one-to-one propensity score. Primary endpoint was the mismatch between the intended (HPre) and the final (HPost) implantation depth. LZ curvature and angulation were calculated based on the aortic centerline trajectory available from pre-TAVI computed tomography. Total LZ curvature ( k L Z , t o t ) and LZ angulation distal to aortic annulus ( α L Z , D i s t a l ) were greater in the SE compared to the BE group (P < 0.001 for both). In the BE group, HPost was significantly higher than HPre at both cusps (P < 0.001). In the SE group, HPost was significantly deeper than HPre only at the left coronary cusp (P = 0.013). At multivariate analysis, α L Z , D i s t a l was the only independent predictor (OR = 1.11, P = 0.002) of deeper final implantation depth with a cut-off value of 17.8°. Aortic LZ curvature and angulation significantly affected final TAVI implantation depth, especially in high stent-frame SE devices reporting, upon complete release, deeper implantation depth with respect to the intended one.


Subject(s)
Aortic Valve Stenosis , Aortic Valve , Transcatheter Aortic Valve Replacement , Transcatheter Aortic Valve Replacement/methods , Humans , Male , Female , Aged, 80 and over , Aged , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Aortic Valve Stenosis/surgery , Tomography, X-Ray Computed , Aorta/diagnostic imaging , Aorta/surgery , Treatment Outcome , Heart Valve Prosthesis , Retrospective Studies
3.
Int J Comput Assist Radiol Surg ; 19(4): 757-766, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38386176

ABSTRACT

PURPOSE: Intracardiac transcatheter interventions allow for reducing trauma and hospitalization stays as compared to standard surgery. In the treatment of mitral regurgitation, the most widely adopted transcatheter approach consists in deploying a clip on the mitral valve leaflets by means of a catheter that is run through veins from a peripheral access to the left atrium. However, precise manipulation of the catheter from outside the body while copying with the path constraints imposed by the vessels remains challenging. METHODS: We proposed a path tracking control framework that provides adequate motion commands to the robotic steerable catheter for autonomous navigation through vascular lumens. The proposed work implements a catheter kinematic model featuring nonholonomic constraints. Relying on the real-time measurements from an electromagnetic sensor and a fiber Bragg grating sensor, a two-level feedback controller was designed to control the catheter. RESULTS: The proposed method was tested in a patient-specific vessel phantom. A median position error between the center line of the vessel and the catheter tip trajectory was found to be below 2 mm, with a maximum error below 3 mm. Statistical testing confirmed that the performance of the proposed method exhibited no significant difference in both free space and the contact region. CONCLUSION: The preliminary in vitro studies presented in this paper showed promising accuracy in navigating the catheter within the vessel. The proposed approach enables autonomous control of a steerable catheter for transcatheter cardiology interventions without the request of calibrating the intuitive parameters or acquiring a training dataset.


Subject(s)
Cardiology , Mitral Valve Insufficiency , Robotics , Humans , Catheters , Mitral Valve
4.
Comput Biol Med ; 163: 107147, 2023 09.
Article in English | MEDLINE | ID: mdl-37329622

ABSTRACT

Accurate planning of transcatheter aortic valve implantation (TAVI) is important to minimize complications, and it requires anatomic evaluation of the aortic root (AR), commonly performed through 3D computed tomography (CT) image analysis. Currently, there is no standard automated solution for this process. Two convolutional neural networks with 3D U-Net architectures (model 1 and model 2) were trained on 310 CT scans for AR analysis. Model 1 performs AR segmentation and model 2 identifies the aortic annulus and sinotubular junction (STJ) contours. After training, the two models were integrated into a fully automated pipeline for geometric analysis of the AR. Results were validated against manual measurements of 178 TAVI candidates. The trained CNNs segmented the AR, annulus, and STJ effectively, resulting in mean Dice scores of 0.93 for the AR, and mean surface distances of 0.73 mm and 0.99 mm for the annulus and STJ, respectively. Automatic measurements were in good agreement with manual annotations, yielding annulus diameters that differed by 0.52 [-2.96, 4.00] mm (bias and 95% limits of agreement for manual minus algorithm). Evaluating the area-derived diameter, bias, and limits of agreement were 0.07 [-0.25, 0.39] mm. STJ and sinuses diameters computed by the automatic method yielded differences of 0.16 [-2.03, 2.34] and 0.1 [-2.93, 3.13] mm, respectively. The proposed tool is a fully automatic solution to quantify morphological biomarkers for pre-TAVI planning. The method was validated against manual annotation from clinical experts and showed to be quick and effective in assessing AR anatomy, with potential for time and cost savings.


Subject(s)
Aortic Valve Stenosis , Deep Learning , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/methods , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/surgery , Aorta, Thoracic , Tomography, X-Ray Computed/methods
5.
Front Cardiovasc Med ; 10: 1103751, 2023.
Article in English | MEDLINE | ID: mdl-37025678

ABSTRACT

The total kinetic energy (KE) of blood can be decomposed into mean KE (MKE) and turbulent KE (TKE), which are associated with the phase-averaged fluid velocity field and the instantaneous velocity fluctuations, respectively. The aim of this study was to explore the effects of pharmacologically induced stress on MKE and TKE in the left ventricle (LV) in a cohort of healthy volunteers. 4D Flow MRI data were acquired in eleven subjects at rest and after dobutamine infusion, at a heart rate that was ∼60% higher than the one in rest conditions. MKE and TKE were computed as volume integrals over the whole LV and as data mapped to functional LV flow components, i.e., direct flow, retained inflow, delayed ejection flow and residual volume. Diastolic MKE and TKE increased under stress, in particular at peak early filling and peak atrial contraction. Augmented LV inotropy and cardiac frequency also caused an increase in direct flow and retained inflow MKE and TKE. However, the TKE/KE ratio remained comparable between rest and stress conditions, suggesting that LV intracavitary fluid dynamics can adapt to stress conditions without altering the TKE to KE balance of the normal left ventricle at rest.

6.
Comput Methods Programs Biomed ; 233: 107468, 2023 May.
Article in English | MEDLINE | ID: mdl-36921465

ABSTRACT

BACKGROUND AND OBJECTIVE: Numerical simulations of blood flow are a valuable tool to investigate the pathophysiology of ascending thoratic aortic aneurysms (ATAA). To accurately reproduce in vivo hemodynamics, computational fluid dynamics (CFD) models must employ realistic inflow boundary conditions (BCs). However, the limited availability of in vivo velocity measurements, still makes researchers resort to idealized BCs. The aim of this study was to generate and thoroughly characterize a large dataset of synthetic 4D aortic velocity profiles sampled on a 2D cross-section along the ascending aorta with features similar to clinical cohorts of patients with ATAA. METHODS: Time-resolved 3D phase contrast magnetic resonance (4D flow MRI) scans of 30 subjects with ATAA were processed through in-house code to extract anatomically consistent cross-sectional planes along the ascending aorta, ensuring spatial alignment among all planes and interpolating all velocity fields to a reference configuration. Velocity profiles of the clinical cohort were extensively characterized by computing flow morphology descriptors of both spatial and temporal features. By exploiting principal component analysis (PCA), a statistical shape model (SSM) of 4D aortic velocity profiles was built and a dataset of 437 synthetic cases with realistic properties was generated. RESULTS: Comparison between clinical and synthetic datasets showed that the synthetic data presented similar characteristics as the clinical population in terms of key morphological parameters. The average velocity profile qualitatively resembled a parabolic-shaped profile, but was quantitatively characterized by more complex flow patterns which an idealized profile would not replicate. Statistically significant correlations were found between PCA principal modes of variation and flow descriptors. CONCLUSIONS: We built a data-driven generative model of 4D aortic inlet velocity profiles, suitable to be used in computational studies of blood flow. The proposed software system also allows to map any of the generated velocity profiles to the inlet plane of any virtual subject given its coordinate set.


Subject(s)
Aorta, Thoracic , Aortic Aneurysm , Humans , Aorta, Thoracic/physiology , Cross-Sectional Studies , Aorta/physiology , Magnetic Resonance Imaging , Hemodynamics/physiology , Aortic Aneurysm/diagnostic imaging , Blood Flow Velocity
7.
J Endovasc Ther ; 30(5): 756-768, 2023 10.
Article in English | MEDLINE | ID: mdl-35588222

ABSTRACT

PURPOSE: Displacement forces (DFs) identify hostile landing zones for stent graft deployment in thoracic endovascular aortic repair (TEVAR). However, their use in TEVAR planning is hampered by the need for time-expensive computational fluid dynamics (CFD). We propose a novel fast-approximate computation of DFs merely exploiting aortic arch anatomy, as derived from the computed tomography (CT) and a measure of central aortic pressure. MATERIALS AND METHODS: We tested the fast-approximate approach against CFD gold-standard in 34 subjects with the "bovine" aortic arch variant. For each dataset, a 3-dimensional (3D) model of the aortic arch lumen was reconstructed from computed tomography angiography and CFD then employed to compute DFs within the aortic proximal landing zones. To quantify fast-approximate DFs, the wall shear stress contribution to the DF was neglected and blood pressure space-distribution was averaged on the entire aortic wall to reliably approximate the patient-specific central blood pressure. Also, DF values were normalized on the corresponding proximal landing zone area to obtain the equivalent surface traction (EST). RESULTS: Fast-approximate approach consistently reflected (r2=0.99, p<0.0001) the DF pattern obtained by CFD, with a -1.1% and 0.7° bias in DFs magnitude and orientation, respectively. The normalized EST progressively increased (p<0.0001) from zone 0 to zone 3 regardless of the type of arch, with proximal landing zone 3 showing significantly greater forces than zone 2 (p<0.0001). Upon DF normalization to the corresponding aortic surface, fast-approximate EST was decoupled in blood pressure and a dimensionless shape vector (S) reflecting aortic arch morphology. S showed a zone-specific pattern of orientation and proved a valid biomechanical blueprint of DF impact on the thoracic aortic wall. CONCLUSION: Requiring only a few seconds and quantifying clinically relevant biomechanical parameters of proximal landing zones for arch TEVAR, our method suits the real preoperative decision-making process. It paves the way toward analyzing large population of patients and hence to define threshold values for a future patient-specific preoperative TEVAR planning.


Subject(s)
Blood Vessel Prosthesis Implantation , Endovascular Procedures , Humans , Aorta, Thoracic/diagnostic imaging , Aorta, Thoracic/surgery , Blood Vessel Prosthesis , Blood Vessel Prosthesis Implantation/adverse effects , Endovascular Procedures/adverse effects , Endovascular Procedures/methods , Treatment Outcome , Stents
8.
J Thorac Cardiovasc Surg ; 165(4): 1418-1429.e4, 2023 04.
Article in English | MEDLINE | ID: mdl-33781593

ABSTRACT

OBJECTIVE: The study objective was to elucidate the mechanisms of left ventricle functional recovery in terms of endocardial contractility and synchronicity after surgical ventricular reconstruction. METHODS: Real-time 3-dimensional transthoracic echocardiography was performed on 20 patients with anterior left ventricle remodeling and ischemic heart failure before surgical ventricular reconstruction and at 6-month follow-up, and on 15 healthy controls matched by age and body surface area. Real-time 3-dimensional transthoracic echocardiography datasets were analyzed through TomTec software (4D LV-Analysis; TomTec Imaging Systems GmbH, Unterschleissheim, Germany): Left ventricle volumes, ejection fraction, and global longitudinal strain were computed; the time-dependent endocardial surface yielded by 3-dimensional speckle-tracking echocardiography was postprocessed through in-house software to quantify local systolic minimum principal strain as a measure of fiber shortening and mechanical dispersion as a measure of fiber synchronicity. RESULTS: Compared with controls, patients with heart failure before surgical ventricular reconstruction showed lower ejection fraction (P < .0001) and significantly impaired mechanical dispersion (P < .0001) and minimum principal strain (P < .0001); the latter worsened progressively from left ventricle base to apex. After surgical ventricular reconstruction, global longitudinal strain improved from -6.7% to -11.3% (P < .0001); mechanical dispersion decreased in every left ventricle region (P ≤ .017) and mostly in the basal region, where computed mechanical dispersion values were comparable to physiologic values (P ≥ .046); minimum principal strain improved mostly in the basal region, changing from -16.6% to -22.3% (P = .0027). CONCLUSIONS: At 6-month follow-up, surgical ventricular reconstruction was associated with significant recovery in global left ventricle function, improved mechanical dispersion indicating a more synchronous left ventricle contraction, and improved left ventricle fiber shortening mostly in the basal region, suggesting the major role of the remote myocardium in enhancing left ventricle functional recovery.


Subject(s)
Echocardiography, Three-Dimensional , Heart Failure , Ventricular Dysfunction, Left , Humans , Ventricular Function, Left/physiology , Echocardiography/methods , Echocardiography, Three-Dimensional/methods , Heart Failure/diagnostic imaging , Heart Failure/surgery , Heart Ventricles/diagnostic imaging , Heart Ventricles/surgery , Stroke Volume/physiology , Reproducibility of Results
9.
Quant Imaging Med Surg ; 12(7): 3515-3527, 2022 Jul.
Article in English | MEDLINE | ID: mdl-35782271

ABSTRACT

Background: Performance and durability of arterio-venous grafts depend on their ability to mimic the mechanical behavior of the anastomized blood vessels. To select the most suitable synthetic graft, in vivo evaluation of the radial deformability of peripheral arteries and veins could be crucial; however, a standardized non-invasive strategy is still missing. Herein, we sought to define a novel and user-friendly clinical protocol for in vivo assessment of the arm vessel deformability. Methods: A dedicated protocol, applied on 30 volunteers, was specifically designed to estimate both compliance and distensibility of the brachial and radial arteries, and of the basilic and cephalic veins. Bi-dimensional ultrasound imaging was used to acquire cross-sectional areas (CSAs) of arteries in clinostatic configuration, and CSAs of veins combining clinostatic and orthostatic configurations. Arterial pulse pressure was measured with a digital sphygmomanometer, while venous hydrostatic pressure was derived from the arm length in orthostatic configuration. Results: For each participant, all CSAs were successfully extracted from ultrasound images. The basilic vein and the radial artery exhibited the largest (21.5±8.9 mm2) and the smallest (3.4±1.0 mm2) CSAs, respectively; CSA measurements were highly repeatable (Bland-Altman bias <10% and Pearson correlation ≥0.90, for both arteries and veins). In veins, compliance and distensibility were higher than in arteries; compliance was significantly higher (P<0.0001) in the brachial than in the radial artery (3.52×10-4 vs. 1.3×10-4 cm2/mmHg); it was three times larger in basilic veins than in cephalic veins (17.4×10-4 vs. 5.6×10-4 cm2/mmHg, P<0.0001). Conclusions: The proposed non-invasive protocol proved feasible, effective and adequate for daily clinical practice, allowing for the estimation of patient-specific compliance and distensibility of peripheral arteries and veins. If further extended, it may contribute to the fabrication of biohybrid arterio-venous grafts, paving the way towards patient-tailored solutions for vascular access.

10.
Int J Cardiol ; 362: 183-189, 2022 09 01.
Article in English | MEDLINE | ID: mdl-35504452

ABSTRACT

BACKGROUND: Left atrial (LA) function can be effectively assessed by measuring longitudinal LA strain (LAS) via two-dimensional speckle tracking echocardiography (2DSTE). Here, we test 2DSTE-based LAS as marker of different left ventricle (LV) remodeling patterns and as prognostic index in ischemic heart failure (HF) candidates to surgical ventricular reconstruction. METHODS: We retrospectively considered ischemic HF patients with anterior (group A, n=130) or posterior (group P, n=48) LV remodeling. Based on 2D ultrasound, LV and LA morpho-functional parameters were quantified including reservoir (LASRes), conduit (LASCond) and booster (LASBoost) LAS. We tested their capability to discriminate between groups A and P, and their group-specific prognostic significance for the composite end-point of death or HF re-hospitalization at follow-up (mean follow-up time=40 months, range 3-101 months). RESULTS: Group A and group P displayed similar end-diastolic (p=0.89) and end-systolic (p=0.33) LV volume index, and LA volume index LAVi (p=0.44) corrected for the degree of mitral regurgitation. As compared to group P, group A revealed a significant reduction in LASBoost (9.2±0.4% vs. 11.1±0.7%, p=0.04) and a non-significant reduction in LASRes (16.9±0.7% vs. 19.3±1.1%, p=0.06). Kaplan-Meier curves showed that the median LASRes and LASBoost values effectively stratified patients based on their prognosis in the overall study population (Log-rank p=0.002 and Log_rank p<0.0001) and in group A, where the association was stronger for LASBoost (Log-rank p<0.001) than for LASRes (Log-rank p=0.013). CONCLUSIONS: 2DSTE-based LAS assessment is affordable, repeatable and non-invasive, and could add clinically-relevant mechanistic insight and prognostic value in the stratification of ischemic HF patients.


Subject(s)
Heart Atria , Heart Failure , Heart Atria/diagnostic imaging , Heart Failure/diagnostic imaging , Humans , Prognosis , Retrospective Studies , Ultrasonography , Ventricular Remodeling
11.
Eur Heart J ; 43(28): 2672-2684, 2022 07 21.
Article in English | MEDLINE | ID: mdl-35608227

ABSTRACT

Congenital heart disease (CHD) is often comprised of complex three-dimensional (3D) anatomy that must be well understood to assess the pathophysiological consequences and guide therapy. Thus, detailed cardiac imaging for early detection and planning of interventional and/or surgical treatment is paramount. Advanced technologies have revolutionized diagnostic and therapeutic practice in CHD, thus playing an increasing role in its management. Traditional reliance on standard imaging modalities including echocardiography, cardiac computed tomography (CT) and magnetic resonance imaging (MRI) has been augmented by the use of recent technologies such as 3D printing, virtual reality, augmented reality, computational modelling, and artificial intelligence because of insufficient information available with these standard imaging techniques. This has created potential opportunities of incorporating these technologies into routine clinical practice to achieve the best outcomes through delivery of personalized medicine. In this review, we provide an overview of these evolving technologies and a new approach enabling physicians to better understand their real-world application in adult CHD as a prelude to clinical workflow implementation.


Subject(s)
Heart Defects, Congenital , Virtual Reality , Adult , Artificial Intelligence , Heart , Heart Defects, Congenital/surgery , Humans , Printing, Three-Dimensional
12.
J Digit Imaging ; 35(2): 226-239, 2022 04.
Article in English | MEDLINE | ID: mdl-35083618

ABSTRACT

Feasibility assessment and planning of thoracic endovascular aortic repair (TEVAR) require computed tomography (CT)-based analysis of geometric aortic features to identify adequate landing zones (LZs) for endograft deployment. However, no consensus exists on how to take the necessary measurements from CT image data. We trained and applied a fully automated pipeline embedding a convolutional neural network (CNN), which feeds on 3D CT images to automatically segment the thoracic aorta, detects proximal landing zones (PLZs), and quantifies geometric features that are relevant for TEVAR planning. For 465 CT scans, the thoracic aorta and pulmonary arteries were manually segmented; 395 randomly selected scans with the corresponding ground truth segmentations were used to train a CNN with a 3D U-Net architecture. The remaining 70 scans were used for testing. The trained CNN was embedded within computational geometry processing pipeline which provides aortic metrics of interest for TEVAR planning. The resulting metrics included aortic arch centerline radius of curvature, proximal landing zones (PLZs) maximum diameters, angulation, and tortuosity. These parameters were statistically analyzed to compare standard arches vs. arches with a common origin of the innominate and left carotid artery (CILCA). The trained CNN yielded a mean Dice score of 0.95 and was able to generalize to 9 pathological cases of thoracic aortic aneurysm, providing accurate segmentations. CILCA arches were characterized by significantly greater angulation (p = 0.015) and tortuosity (p = 0.048) in PLZ 3 vs. standard arches. For both arch configurations, comparisons among PLZs revealed statistically significant differences in maximum zone diameters (p < 0.0001), angulation (p < 0.0001), and tortuosity (p < 0.0001). Our tool allows clinicians to obtain objective and repeatable PLZs mapping, and a range of automatically derived complex aortic metrics.


Subject(s)
Blood Vessel Prosthesis Implantation , Deep Learning , Endovascular Procedures , Aorta, Thoracic/diagnostic imaging , Aorta, Thoracic/surgery , Aortography/methods , Blood Vessel Prosthesis , Computed Tomography Angiography , Endovascular Procedures/methods , Humans , Retrospective Studies , Tomography, X-Ray Computed , Treatment Outcome
13.
J Magn Reson Imaging ; 56(4): 1157-1170, 2022 Oct.
Article in English | MEDLINE | ID: mdl-35075711

ABSTRACT

BACKGROUND: Time-resolved three-directional velocity-encoded (4D flow) magnetic resonance imaging (MRI) enables the quantification of left ventricular (LV) intracavitary fluid dynamics and energetics, providing mechanistic insight into LV dysfunctions. Before becoming a support to diagnosis and patient stratification, this analysis should prove capable of discriminating between clearly different LV derangements. PURPOSE: To investigate the potential of 4D flow in identifying fluid dynamic and energetics derangements in ischemic and restrictive LV cardiomyopathies. STUDY TYPE: Prospective observational study. POPULATION: Ten patients with post-ischemic cardiomyopathy (ICM), 10 patients with cardiac light-chain cardiac amyloidosis (AL-CA), and 10 healthy controls were included. FIELD STRENGTH/SEQUENCE: 1.5 T/balanced steady-state free precession cine and 4D flow sequences. ASSESSMENT: Flow was divided into four components: direct flow (DF), retained inflow, delayed ejection flow, and residual volume (RV). Demographics, LV morphology, flow components, global and regional energetics (volume-normalized kinetic energy [KEV ] and viscous energy loss [ELV ]), and pressure-derived hemodynamic force (HDF) were compared between the three groups. STATISTICAL TESTS: Intergroup differences in flow components were tested by one-way analysis of variance (ANOVA); differences in energetic variables and peak HDF were tested by two-way ANOVA. A P-value of <0.05 was considered significant. RESULTS: ICM patients exhibited the following statistically significant alterations vs. controls: reduced KEV , mostly in the basal region, in systole (-44%) and in diastole (-37%); altered flow components, with reduced DF (-33%) and increased RV (+26%); and reduced basal-apical HDF component on average by 63% at peak systole. AL-CA patients exhibited the following alterations vs. controls: significantly reduced KEV at the E-wave peak in the basal segment (-34%); albeit nonstatistically significant, increased peaks and altered time-course of the HDF basal-apical component in diastole and slightly reduced HDF components in systole. DATA CONCLUSION: The analysis of multiple 4D flow-derived parameters highlighted fluid dynamic alterations associated with systolic and diastolic dysfunctions in ICM and AL-CA patients, respectively. LEVEL OF EVIDENCE: 2 TECHNICAL EFFICACY STAGE: 3.


Subject(s)
Cardiomyopathy, Restrictive , Hydrodynamics , Heart Ventricles/diagnostic imaging , Humans , Magnetic Resonance Imaging/methods , Magnetic Resonance Imaging, Cine/methods , Stroke Volume , Ventricular Function, Left
14.
Front Cardiovasc Med ; 9: 1076359, 2022.
Article in English | MEDLINE | ID: mdl-36704466

ABSTRACT

An 8-year-old girl, diagnosed with mid-aortic syndrome (MAS) at the age of 2 months and under antihypertensive therapy, presented with severe systemic hypertension (>200/120 mmHg). Computed tomography (CT) examination revealed aortic aneurysm between severe stenoses at pre- and infra-renal segments, and occlusion of principal splanchnic arteries with peripheral collateral revascularization. Based on CT imaging, preoperative three-dimensional (3D) anatomy was reconstructed to assess aortic dimensions and a dedicated in vitro planning platform was designed to investigate the feasibility of a stenting procedure under fluoroscopic guidance. The in vitro system was designed to incorporate a translucent flexible 3D-printed patient-specific model filled with saline. A covered 8-zig 45-mm-long Cheatham-Platinum (CP) stent and a bare 8-zig, 34-mm-long CP stent were implanted with partial overlap to treat the stenoses (global peak-to-peak pressure gradient > 60 mmHg), excluding the aneurysm and avoiding risk of renal arteries occlusion. Percutaneous procedure was successfully performed with no residual pressure gradient and exactly replicating the strategy tested in vitro. Also, as investigated on the 3D-printed model, additional angioplasty was feasible across the frames of the stent to improve bilateral renal flow. Postoperative systemic pressure significantly reduced (130/70 mmHg) as well as dosage of antihypertensive therapy. This is the first report demonstrating the use of a 3D-printed model to effectively plan percutaneous intervention in a complex pediatric MAS case: taking full advantage of the combined use of a patient-specific 3D model and a dedicated in vitro platform, feasibility of the stenting procedure was successfully tested during pre-procedural assessment. Hence, use of patient-specific 3D-printed models and in vitro dedicated platforms is encouraged to assist pre-procedural planning and personalize treatment, thus enhancing intervention success.

15.
Int J Numer Method Biomed Eng ; 37(5): e3447, 2021 05.
Article in English | MEDLINE | ID: mdl-33586336

ABSTRACT

We propose a surrogate model for the fluid-structure interaction (FSI) problem for the study of blood dynamics in carotid arteries in presence of plaque. This is based on the integration of a numerical model with subject-specific data and clinical imaging. We propose to model the plaque as part of the tissues surrounding the vessel wall through the application of an elastic support boundary condition. In order to characterize the plaque and other surrounding tissues, such as the close-by jugular vein, the elastic parameters of the boundary condition were spatially differentiated and their values were estimated by minimizing the discrepancies between computed vessel displacements and reference values obtained from CINE Magnetic Resonance Imaging data. We applied the model to three subjects with a degree of stenosis greater than 70%. We found that accounting for both plaque and jugular vein in the estimation of the elastic parameters increases the accuracy. In particular, in all patients, mismatches between computed and in vivo measured wall displacements were one to two orders of magnitude lower than the spatial resolution of the original MRI data. These results confirmed the validity of the proposed surrogate plaque model. We also compared fluid-dynamics results with those obtained in a fixed wall setting and in a full FSI model, used as gold standard, highlighting the better accordance of our results in comparison to the rigid ones.


Subject(s)
Plaque, Atherosclerotic , Songbirds , Animals , Carotid Arteries/diagnostic imaging , Humans , Magnetic Resonance Imaging , Magnetic Resonance Imaging, Cine , Plaque, Atherosclerotic/diagnostic imaging
16.
J Biomech ; 119: 110308, 2021 04 15.
Article in English | MEDLINE | ID: mdl-33631666

ABSTRACT

Blood is generally modeled as a Newtonian fluid, assuming a standard and constant viscosity; however, this assumption may not hold for the highly pulsatile and recirculating intracavitary flow in the left ventricle (LV), hampering the quantification of fluid dynamic indices of potential clinical relevance. Herein, we investigated the effect of three viscosity models on the patient-specific quantification of LV blood energetics, namely on viscous energy loss (EL), from 4D Flow magnetic resonance imaging: I) Newtonian with standard viscosity (3.7 cP), II) Newtonian with subject-specific hematocrit-dependent viscosity, III) non-Newtonian accounting for the effect of hematocrit and shear rate. Analyses were performed on 5 controls and 5 patients with cardiac light-chain amyloidosis. In Model II, viscosity ranged between 3.0 (-19%) and 4.3 cP (+16%), mildly deviating from the standard value. In the non-Newtonian model, this effect was emphasized: viscosity ranged from 3.2 to 6.0 cP, deviating maximally from the standard value in low shear rate (i.e., <100 s-1) regions. This effect reflected on EL quantifications: in particular, as compared to Model I, Model III yielded markedly higher EL values (up to +40%) or markedly lower (down to -21%) for subjects with hematocrit higher than 39.5% and lower than 30%, respectively. Accounting for non-Newtonian blood behavior on a patient-specific basis may enhance the accuracy of intracardiac energetics assessment by 4D Flow, which may be explored as non-invasive index to discriminate between healthy and pathologic LV.


Subject(s)
Heart Ventricles , Models, Cardiovascular , Blood Flow Velocity , Blood Viscosity , Heart Ventricles/diagnostic imaging , Hematocrit , Humans , Pulsatile Flow , Stress, Mechanical , Viscosity
17.
Curr Probl Cardiol ; 46(3): 100428, 2021 Mar.
Article in English | MEDLINE | ID: mdl-31296418

ABSTRACT

The current management of aortic dilatation associated with congenital bicuspid aortic valve (bicuspid aortic valve aortopathy) is based on dimensional parameters (diameter of the aneurysm, growth of the diameter over time) and few other criteria. The disease is however heterogeneous in terms of natural and clinical history and risk of acute complications, ie aortic dissection. Dimensional criteria are now admitted to have limited value as predictors of such complications. Thus, novel principles for risk stratification have been recently investigated, including phenotypic criteria, flow-related metrics, and circulating biomarkers. A systematization of the typical anatomoclinical forms that the aortopathy can assume has led to the identification of the more severe root phenotype, associated with higher risk of progression of the aneurysm and possible higher aortic dissection risk. Four-dimensional-flow magnetic resonance imaging studies are searching for potentially clinically significant metrics of flow derangement, based on the recognized association of local abnormal shear stress with wall pathology. Other research initiatives are addressing the question whether circulating molecules could predict the presence or, more importantly, the future development of aortopathy. The present review summarizes the latest progresses in the knowledge on risk stratification of bicuspid aortic valve aortopathy, focusing on critical aspects and debated points.


Subject(s)
Aortic Valve Stenosis , Bicuspid Aortic Valve Disease , Heart Valve Diseases , Aortic Valve/diagnostic imaging , Aortic Valve/pathology , Heart Valve Diseases/diagnostic imaging , Heart Valve Diseases/pathology , Humans , Risk Assessment
18.
J Cardiovasc Transl Res ; 14(3): 513-524, 2021 06.
Article in English | MEDLINE | ID: mdl-32959169

ABSTRACT

Transcatheter therapies are emerging for functional mitral regurgitation (FMR) treatment, however there is lack of pathological models for their preclinical assessment. We investigated the applicability of deer hearts for this purpose.8 whole deer hearts were housed in a pulsatile flow bench. At baseline, all mitral valves featured normal coaptation. The pathological state was induced by 60-minutes intraventricular constant pressurization. It caused mitral annulus dilation (antero-posterior diameter increase from 31.8 ± 5.6 mm to 39.5 ± 4.9 mm, p = 0.001), leaflets tethering (maximal tenting height increase from 7.3 ± 2.5 mm to 12.7 ± 3.4 mm, p < 0.001) and left ventricular diameter increase (from 67.8 ± 7.5 mm to 79.4 ± 6.5 mm, p = 0.004). These geometrical reconfigurations led to restricted mitral valve leaflets motion and leaflet coaptation loss. Preliminary feasibility assessment of two FMR treatments was performed in the developed model.Deer hearts showed ability to dilate under constant pressurization and have potential to be used for realistic preclinical research of novel FMR therapies. Graphical abstract figure legend: Deer heart mitral valve fiberscopic and echocardiographic images in peak systole at baseline and after inducing the pathological conditions representing functional mitral regurgitation. In the pathological conditions lack of coaptation between the leaflets, enlargement of the antero-posterior distance (red dashed line) and the left ventricular diameter (orange dashed line) were observed.


Subject(s)
Hemodynamics , Mitral Valve Insufficiency/physiopathology , Mitral Valve/physiopathology , Animals , Deer , Disease Models, Animal , Echocardiography, Three-Dimensional , Fiber Optic Technology , Isolated Heart Preparation , Mitral Valve/diagnostic imaging , Mitral Valve Insufficiency/diagnostic imaging , Ventricular Function, Left
20.
J Biomech ; 105: 109796, 2020 05 22.
Article in English | MEDLINE | ID: mdl-32423542

ABSTRACT

Endovascular stenting has recently become a standard treatment for native coarctation of the aorta (CoA) in children and young adults, given the efficacy in relieving vessel obstruction with a low incidence of adverse events. Yet, despite the short-term success of the technique, late hypertension remains an endemic risk. To assess the impact of the percutaneous procedure on the aortic wall biomechanics, we designed a novel finite element (FE) protocol for the simulation of endovascular stenting in three patient-specific CoA anatomies, developing a remeshing procedure that allows for coping with different CoA severities. Our FE protocol was able to yield numerical results on stent distortions and stresses, as well as on changes in aortic wall stresses and distensibility. These results were consistent with intraprocedural in-vivo evidences and with previous findings from the literature, and they suggest that our numerical approach could be used to understand the role of patient specific anatomical features (CoA severity and arch type) on the post-stenting aortic biomechanics. If soundly validated on a vast cohort of patients, our approach could support patient selection for the procedure.


Subject(s)
Aortic Coarctation , Stents , Aorta , Biomechanical Phenomena , Child , Finite Element Analysis , Humans , Treatment Outcome , Young Adult