Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Language
Publication year range
1.
J Neural Eng ; 20(1)2023 01 18.
Article in English | MEDLINE | ID: mdl-36535037

ABSTRACT

Objective.Although electrical vagus nerve stimulation has been shown to augment parasympathetic control of the heart, the effects of electrical conduction block have been less rigorously characterized. Previous experiments have demonstrated that direct current (DC) nerve block can be applied safely and effectively in the autonomic system, but additional information about the system dynamics need to be characterized to successfully deploy DC nerve block to clinical practice.Approach.The dynamics of the heart rate (HR) from DC nerve block of the vagus nerve were measured by stimulating the vagus nerve to lower the HR, and then applying DC block to restore normal rate. DC block achieved rapid, complete block, as well as partial block at lower amplitudes.Main Results. Complete block was also achieved using lower amplitudes, but with a slower induction time. The time for DC to induce complete block was significantly predicted by the amplitude; specifically, the amplitude expressed as a percentage of the current required for a rapid, 60 s induction time. Recovery times after the cessation of DC block could occur both instantly, and after a significant delay. Both blocking duration and injected charge were significant in predicting the delay in recovery to normal conduction.Significance. While these data show that broad features such as induction and recovery can be described well by the DC parameters, more precise features of the HR, such as the exact path of the induction and recoveries, are still undefined. These findings show promise for control of the cardiac autonomic nervous system, with potential to expand to the sympathetic inputs as well.


Subject(s)
Vagus Nerve Stimulation , Vagus Nerve , Rats , Animals , Heart Rate/physiology , Vagus Nerve/physiology , Heart/innervation , Heart/physiology , Vagus Nerve Stimulation/methods
2.
Bioelectron Med ; 8(1): 11, 2022 Jul 27.
Article in English | MEDLINE | ID: mdl-35883133

ABSTRACT

OBJECTIVES: KiloHertz frequency alternating current waveforms produce conduction block in peripheral nerves. It is not clearly known how the waveform shape affects block outcomes, and if waveform effects are frequency dependent. We determined the effects of waveform shape using two types of electrodes. MATERIALS AND METHODS: Acute in-vivo experiments were performed on 12 rats. Bipolar electrodes were used to electrically block motor nerve impulses in the sciatic nerve, as measured using force output from the gastrocnemius muscle. Three blocking waveforms were delivered (sinusoidal, square and triangular) at 6 frequencies (10-60 kHz). Bare platinum electrodes were compared with carbon black coated electrodes. We determined the minimum amplitude that could completely block motor nerve conduction (block threshold), and measured properties of the onset response, which is a transient period of nerve activation at the start of block. In-vivo results were compared with computational modeling conducted using the NEURON simulation environment using a nerve membrane model modified for stimulation in the kilohertz frequency range. RESULTS: For the majority of parameters, in-vivo testing and simulations showed similar results: Block thresholds increased linearly with frequency for all three waveforms. Block thresholds were significantly different between waveforms; lowest for the square waveform and highest for triangular waveform. When converted to charge per cycle, square waveforms required the maximum charge per phase, and triangular waveforms the least. Onset parameters were affected by blocking frequency but not by waveform shape. Electrode comparisons were performed only in-vivo. Electrodes with carbon black coatings gave significantly lower block thresholds and reduced onset responses across all blocking frequencies. For 10 and 20 kHz, carbon black coating significantly reduced the charge required for nerve block. CONCLUSIONS: We conclude that both sinusoidal and square waveforms at frequencies of 20 kHz or higher would be optimal. Future investigation of carbon black or other high charge capacity electrodes may be useful in achieving block with lower BTs and onsets. These findings will be of importance for designing clinical nerve block systems.

3.
Am J Physiol Heart Circ Physiol ; 322(1): H105-H115, 2022 01 01.
Article in English | MEDLINE | ID: mdl-34860595

ABSTRACT

Maladaptation of the sympathetic nervous system contributes to the progression of cardiovascular disease and risk for sudden cardiac death, the leading cause of mortality worldwide. Axonal modulation therapy (AMT) directed at the paravertebral chain blocks sympathetic efferent outflow to the heart and maybe a promising strategy to mitigate excess disease-associated sympathoexcitation. The present work evaluates AMT, directed at the sympathetic chain, in blocking sympathoexcitation using a porcine model. In anesthetized porcine (n = 14), we applied AMT to the right T1-T2 paravertebral chain and performed electrical stimulation of the distal portion of the right sympathetic chain (RSS). RSS-evoked changes in heart rate, contractility, ventricular activation recovery interval (ARI), and norepinephrine release were examined with and without kilohertz frequency alternating current block (KHFAC). To evaluate efficacy of AMT in the setting of sympathectomy, evaluations were performed in the intact state and repeated after left and bilateral sympathectomy. We found strong correlations between AMT intensity and block of sympathetic stimulation-evoked changes in cardiac electrical and mechanical indices (r = 0.83-0.96, effect size d = 1.9-5.7), as well as evidence of sustainability and memory. AMT significantly reduced RSS-evoked left ventricular interstitial norepinephrine release, as well as coronary sinus norepinephrine levels. Moreover, AMT remained efficacious following removal of the left sympathetic chain, with similar mitigation of evoked cardiac changes and reduction of catecholamine release. With growth of neuromodulation, an on-demand or reactionary system for reversible AMT may have therapeutic potential for cardiovascular disease-associated sympathoexcitation.NEW & NOTEWORTHY Autonomic imbalance and excess sympathetic activity have been implicated in the pathogenesis of cardiovascular disease and are targets for existing medical therapy. Neuromodulation may allow for control of sympathetic projections to the heart in an on-demand and reversible manner. This study provides proof-of-concept evidence that axonal modulation therapy (AMT) blocks sympathoexcitation by defining scalability, sustainability, and memory properties of AMT. Moreover, AMT directly reduces release of myocardial norepinephrine, a mediator of arrhythmias and heart failure.


Subject(s)
Axons/metabolism , Heart/physiology , Sympathetic Nervous System/physiology , Synaptic Transmission , Animals , Axons/physiology , Catecholamines/metabolism , Electric Stimulation , Female , Heart/innervation , Heart Rate , Male , Myocardial Contraction , Norepinephrine/metabolism , Swine , Sympathetic Nervous System/metabolism
4.
Int IEEE EMBS Conf Neural Eng ; 2021: 1083-1086, 2021 May.
Article in English | MEDLINE | ID: mdl-34909125

ABSTRACT

Although vagus nerve stimulation (VNS) can be used to reduce heartrate by enhancing parasympathetic activity, a fully controllable intervention would also require a method for downregulating parasympathetic activity. A direct current (DC) block can be applied to a nerve to block its action potential conduction. This nerve block can be used to downregulate parasympathetic activity by blocking afferent reflexes. The damaging effects of reactions that occur at the electrode-nerve interface using conventional platinum electrodes can be avoided by separating the electrode from the nerve. Using a biocompatible, ionically conducting medium, the electrode and the damaging reactions can be isolated in a vessel away from the nerve. This type of electrode has been called the Separated Interface Nerve Electrode (SINE). Fuzzy logic control (FLC) is a controller approach that is well suited to physiological systems. The SINE, controlled by an FLC, was utilized to block a stimulated vagus nerve and regulate heart rate. The FLC was able to maintain the heartrate at a pre-determined setpoint while still achieving instant recovery when the block was removed.

5.
IEEE Trans Neural Syst Rehabil Eng ; 27(5): 836-845, 2019 05.
Article in English | MEDLINE | ID: mdl-30951474

ABSTRACT

Direct current (DC) nerve block has been shown to provide a complete block of nerve conduction without unwanted neural firing. Previous work shows that high capacitance electrodes can be used to safely deliver a DC block. Another way of delivering DC safely is through a separated interface nerve electrode (SINE), such that any reactive species that are generated by the passage of DC are contained in a vessel away from the nerve. This design has been enhanced by using a high capacitance carbon "slurry" as the electrode in the external vessel to extend the capacity of the electrode (CSINE). With this new design, it was possible to provide 50 min of continuous nerve block without recharge while still maintaining complete recovery of neural signals. Up to 46 C of charge delivery was applied for a total of 4 h of nerve block with complete recovery. Because of the extended delivery time, it was possible to explore several properties of DC block that would not be revealed without the capability of a long-duration continuous block. It was possible to achieve complete block at lower values of DC if the block was applied for a longer period of time. Depending on the amount of charge applied during the block, the recovery was delayed for a period of time before complete force recovery was restored. These new properties provide novel techniques for device development to optimize charge delivery time and device powering concerns.


Subject(s)
Electric Stimulation/instrumentation , Electrodes , Nerve Block , Neural Conduction , Algorithms , Animals , Biocompatible Materials , Bioengineering , Carbon , Equipment Design , Graphite , Muscle, Skeletal/innervation , Muscle, Skeletal/physiology , Rats , Rats, Sprague-Dawley , Sciatic Nerve
6.
Bioelectron Med (Lond) ; 1(1): 39-54, 2018 Jan.
Article in English | MEDLINE | ID: mdl-29480897

ABSTRACT

INTRODUCTION: Electrical nerve block uses electrical waveforms to block action potential propagation. MATERIALS & METHODS: Two key features that distinguish electrical nerve block from other nonelectrical means of nerve block: block occurs instantly, typically within 1 s; and block is fully and rapidly reversible (within seconds). RESULTS: Approaches for achieving electrical nerve block are reviewed, including kilohertz frequency alternating current and charge-balanced polarizing current. We conclude with a discussion of the future directions of electrical nerve block. CONCLUSION: Electrical nerve block is an emerging technique that has many significant advantages over other methods of nerve block. This field is still in its infancy, but a significant expansion in the clinical application of this technique is expected in the coming years.

SELECTION OF CITATIONS
SEARCH DETAIL
...