AJNR Am J Neuroradiol ; 44(3): 297-302, 2023 03.
Article in English | MEDLINE | ID: mdl-36797028

ABSTRACT

BACKGROUND: Middle meningeal artery embolization is an emerging treatment option for chronic subdural hematomas. PURPOSE: Our aim was to assess outcomes following middle meningeal artery embolization by different techniques, including in comparison with traditional surgical methods. DATA SOURCES: We searched the literature databases from inception to March 2022. DATA SELECTION: We selected studies reporting outcomes after middle meningeal artery embolization as a primary or adjunctive treatment for chronic subdural hematoma. DATA ANALYSIS: We analyzed the risk of recurrence of chronic subdural hematoma, reoperation for recurrence or residual hematoma, complications, and radiologic and clinical outcomes using random effects modeling. Additional analyses were performed on the basis of whether middle meningeal artery embolization was used as the primary or adjunct treatment and by embolic agent type. DATA SYNTHESIS: Twenty-two studies were included with 382 patients with middle meningeal artery embolization and 1373 surgical patients. The rate of subdural hematoma recurrence was 4.1%. Fifty (4.2%) patients underwent a reoperation for a recurrent or residual subdural hematoma. Thirty-six (2.6%) experienced postoperative complications. The rates of good radiologic and clinical outcomes were 83.1% and 73.3%, respectively. Middle meningeal artery embolization was significantly associated with decreased odds of subdural hematoma reoperation (OR = 0.48; 95% CI, 23.4-99.1; P = .047) compared with surgery. The lowest rates of subdural hematoma radiologic recurrence, reoperation, and complications were observed among patients receiving embolization with Onyx, whereas good overall clinical outcome occurred most commonly with combined polyvinyl alcohol and coils. LIMITATIONS: A limitation was the retrospective design of studies included. CONCLUSIONS: Middle meningeal artery embolization is safe and effective, either as a primary or adjunctive treatment. Treatment using Onyx seems to yield lower rates of recurrence, rescue operation, and complications whereas particles and coils produce good overall clinical outcomes.


Subject(s)
Embolization, Therapeutic , Hematoma, Subdural, Chronic , Humans , Hematoma, Subdural, Chronic/surgery , Meningeal Arteries , Retrospective Studies , Embolization, Therapeutic/methods , Reoperation
2.
AJNR Am J Neuroradiol ; 43(11): 1615-1620, 2022 11.
Article in English | MEDLINE | ID: mdl-36229166

ABSTRACT

BACKGROUND AND PURPOSE: Flow diversion has gradually become a standard treatment for intracranial aneurysms of the anterior circulation. Recently, the off-label use of the flow diverters to treat posterior circulation aneurysms has also increased despite initial concerns of rupture and the suboptimal results. This study aimed to explore the change in complication rates and treatment outcomes across time for posterior circulation aneurysms treated using flow diversion and to further evaluate the mechanisms and variables that could potentially explain the change and outcomes. MATERIALS AND METHODS: A retrospective review using a standardized data set at multiple international academic institutions was performed to identify patients with ruptured and unruptured posterior circulation aneurysms treated with flow diversion during a decade spanning January 2011 to January 2020. This period was then categorized into 4 intervals. RESULTS: A total of 378 procedures were performed during the study period. Across time, there was an increasing tendency to treat more vertebral artery and fewer large vertebrobasilar aneurysms (P = .05). Moreover, interventionalists have been increasingly using fewer overlapping flow diverters per aneurysm (P = .07). There was a trend toward a decrease in the rate of thromboembolic complications from 15.8% in 2011-13 to 8.9% in 2018-19 (P = .34). CONCLUSIONS: This multicenter experience revealed a trend toward treating fewer basilar aneurysms, smaller aneurysms, and increased usage of a single flow diverter, leading to a decrease in the rate of thromboembolic and hemorrhagic complications.


Subject(s)
Embolization, Therapeutic , Endovascular Procedures , Intracranial Aneurysm , Humans , Endovascular Procedures/methods , Learning Curve , Intracranial Aneurysm/diagnostic imaging , Intracranial Aneurysm/surgery , Treatment Outcome , Cohort Studies , Retrospective Studies , Embolization, Therapeutic/methods , Stents
3.
AJNR Am J Neuroradiol ; 40(1): 92-98, 2019 01.
Article in English | MEDLINE | ID: mdl-30523142

ABSTRACT

BACKGROUND AND PURPOSE: Compressed sensing-sensitivity encoding is a promising MR imaging acceleration technique. This study compares the image quality of compressed sensing-sensitivity encoding accelerated imaging with conventional MR imaging sequences. MATERIALS AND METHODS: Patients with known, treated, or suspected brain tumors underwent compressed sensing-sensitivity encoding accelerated 3D T1-echo-spoiled gradient echo or 3D T2-FLAIR sequences in addition to the corresponding conventional acquisition as part of their clinical brain MR imaging. Two neuroradiologists blinded to sequence and patient information independently evaluated both the accelerated and corresponding conventional acquisitions. The sequences were evaluated on 4- or 5-point Likert scales for overall image quality, SNR, extent/severity of artifacts, and gray-white junction and lesion boundary sharpness. SNR and contrast-to-noise ratio values were compared. RESULTS: Sixty-six patients were included in the study. For T1-echo-spoiled gradient echo, image quality in all 5 metrics was slightly better for compressed sensing-sensitivity encoding than conventional images on average, though it was not statistically significant, and the lower bounds of the 95% confidence intervals indicated that compressed sensing-sensitivity encoding image quality was within 10% of conventional imaging. For T2-FLAIR, image quality of the compressed sensing-sensitivity encoding images was within 10% of the conventional images on average for 3 of 5 metrics. The compressed sensing-sensitivity encoding images had somewhat more artifacts (P = .068) and less gray-white matter sharpness (P = .36) than the conventional images, though neither difference was significant. There was no significant difference in the SNR and contrast-to-noise ratio. There was 25% and 35% scan-time reduction with compressed sensing-sensitivity encoding for FLAIR and echo-spoiled gradient echo sequences, respectively. CONCLUSIONS: Compressed sensing-sensitivity encoding accelerated 3D T1-echo-spoiled gradient echo and T2-FLAIR sequences of the brain show image quality similar to that of standard acquisitions with reduced scan time. Compressed sensing-sensitivity encoding may reduce scan time without sacrificing image quality.