Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
J Nucl Med ; 63(7): 1101-1107, 2022 07.
Article in English | MEDLINE | ID: mdl-34795015

ABSTRACT

Transarterial radioembolization (TARE) is a locoregional radiopharmaceutical therapy based on the delivery of radioactive 90Y microspheres to liver tumors. The importance of personalized dosimetry to make TARE safer and more effective has been demonstrated in recent clinical studies, stressing the need for quantification of the dose-response relationship to ultimately optimize the administered activity before treatment and image it after treatment. 90Y dosimetric studies are challenging because of the lack of accurate and precise methods but are best realized with PET combined with Monte Carlo simulations and other image modalities to calculate a segmental dose distribution. The aim of this study was to assess the suitability of imaging 90Y PET patients with the total-body PET/CT uEXPLORER and to investigate possible improvements in TARE 90Y PET-based dosimetry. The uEXPLORER is the first commercially available ultra-high-resolution (171 cps/kBq) total-body digital PET/CT device with a 194-cm axial PET field of view that enables the whole body to be scanned at a single bed position. Methods: Two PET/CT scanners were evaluated in this study: the Biograph mCT and the total-body uEXPLORER. Images of a National Electrical Manufacturers Association (NEMA) image-quality phantom and 2 patients were reconstructed using our standard clinical oncology protocol. A late portal phase contrast-enhanced CT scan was used to contour the liver segments and create corresponding volumes of interest. To calculate the absorbed dose, Monte Carlo simulations were performed using Geant4 Application for Tomographic Emission (GATE). The absorbed dose and dose-volume histograms were calculated for all 6 spheres (diameters ranging from 10 to 37 mm) of the NEMA phantom, the liver segments, and the entire liver. Differences between the phantom doses and an analytic ground truth were quantified through the root mean squared error. Results: The uEXPLORER showed a higher signal-to-noise ratio at 10- and 13-mm diameters, consistent with its high spatial resolution and system sensitivity. The total liver-absorbed dose showed excellent agreement between the uEXPLORER and the mCT for both patients, with differences lower than 0.2%. Larger differences of up to 60% were observed when comparing the liver segment doses. All dose-volume histograms were in good agreement, with narrower tails for the uEXPLORER in all segments, indicating lower image noise. Conclusion: This patient study is compelling for the use of total-body 90Y PET for liver dosimetry. The uEXPLORER scanner showed a better signal-to-noise ratio than mCT, especially in lower-count regions of interest, which is expected to improve dose quantification and tumor dosimetry.


Subject(s)
Positron Emission Tomography Computed Tomography , Yttrium Radioisotopes , Humans , Monte Carlo Method , Phantoms, Imaging , Radiometry/methods , Yttrium Radioisotopes/therapeutic use
2.
J Vasc Interv Radiol ; 33(2): 150-158.e1, 2022 02.
Article in English | MEDLINE | ID: mdl-34774929

ABSTRACT

PURPOSE: To investigate the degree to which morbidity and mortality (M&M) conferencing is utilized in interventional radiology (IR), identify impediments to its adoption, and assess the experience of those using this tool. MATERIALS AND METHODS: Members of the Society of Interventional Radiology (SIR) were offered a 9-question survey of practices and experiences regarding M&M conferencing within their quality assessment (QA) programs. RESULTS: Among 604 respondents, 37.8% were university-based practitioners and 60% were from outside of university practices. Of all respondents, 43% reported practicing 100% IR, with 28.5% practicing IR 75%-99% and 11% practicing IR <50% of the time. The use of M&M conferencing was significantly greater in university practices (90.7%) than in nonuniversity practices (37.1%) and among practitioners performing at least 75% IR (71.2%) than among those practicing <75% (28.8%). The conferences were held monthly (66.6%) or more often, and the majority (56%) of the events identified were scored using the SIR severity score. Approximately 20% of M&M conferences were multidisciplinary, shared most commonly with vascular surgery. The reasons cited for not using M&M included the lack of time and the logistical challenges of the process. However, among those who participate in M&M conferences, the QA goals of the conference were met at very high rates. CONCLUSIONS: M&M conferencing is well established in university IR programs and among full-time practitioners but much less so elsewhere. For those sites that do not utilize M&M conferencing, there may be a considerable benefit to addressing the obstacles that are limiting their implementation of this tool.


Subject(s)
Quality Improvement , Radiologists , Humans , Morbidity , Radiology, Interventional , Surveys and Questionnaires
3.
Ann Biomed Eng ; 48(5): 1499-1510, 2020 May.
Article in English | MEDLINE | ID: mdl-32006268

ABSTRACT

Yttrium-90 (Y-90) transarterial radioembolization uses radioactive microspheres injected into the hepatic artery to irradiate liver tumors internally. One of the major challenges is the lack of reliable dosimetry methods for dose prediction and dose verification. We present a patient-specific dosimetry approach for personalized treatment planning based on computational fluid dynamics (CFD) simulations of the microsphere transport combined with Y-90 physics modeling called CFDose. The ultimate goal is the development of a software to optimize the amount of activity and injection point for optimal tumor targeting. We present the proof-of-concept of a CFD dosimetry tool based on a patient's angiogram performed in standard-of-care planning. The hepatic arterial tree of the patient was segmented from the cone-beam CT (CBCT) to predict the microsphere transport using multiscale CFD modeling. To calculate the dose distribution, the predicted microsphere distribution was convolved with a Y-90 dose point kernel. Vessels as small as 0.45 mm were segmented, the microsphere distribution between the liver segments using flow analysis was predicted, the volumetric microsphere and resulting dose distribution in the liver volume were computed. The patient was imaged with positron emission tomography (PET) 2 h after radioembolization to evaluate the Y-90 distribution. The dose distribution was found to be consistent with the Y-90 PET images. These results demonstrate the feasibility of developing a complete framework for personalized Y-90 microsphere simulation and dosimetry using patient-specific input parameters.


Subject(s)
Embolization, Therapeutic/methods , Liver Neoplasms/therapy , Radiopharmaceuticals/administration & dosage , Yttrium Radioisotopes/administration & dosage , Computer Simulation , Hepatic Artery/diagnostic imaging , Humans , Hydrodynamics , Liver Neoplasms/diagnostic imaging , Monte Carlo Method , Positron Emission Tomography Computed Tomography , Precision Medicine , Radiometry/methods
SELECTION OF CITATIONS
SEARCH DETAIL
...