Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Language
Publication year range
1.
Med. oral patol. oral cir. bucal (Internet) ; 20(2): e239-e245, mar. 2015. ilus, tab
Article in English | IBECS | ID: ibc-134139

ABSTRACT

OBJECTIVES: To compare the prevalence and the length of mental loop, measured with panoramic radiography (PR)and cone beam computerized tomography (CBCT).MATERIAL AND METHODS: PG and CBCT images where analyzed by a single calibrated examiner to determine the presence and the position of the mental foramen (MF), its distance to the lower mandible border, the anterior length of the mental loop (ML) and the bone quality in 82 PR and 82 CBCT. RESULTS: ML was identified in 36.6 % of PR and 48.8 % of CBCT. PR showed a magnification of 1.87 when compared to CBCT. The mean of anterior extension of the inferior alveolar nerve and the distance to the inferior border of the mandible was higher for PR (2.8 mm, sd 0.91 mm on the PR , range 1.5 to 4.7 mm and 1.59, sd 0.9 on the CBCT ,range 0.4 to 4.0 mm)CONCLUSIONS: There is a magnification in PR images with respect to those of CBCT. The differences between CBCT and PR with regards to the identification and length of the ML are not statistically significant. Identification and accuracy measurements of ML did not depend on the bone quality. Considering that two dimensional imaging provides less accurate and reliable information regarding the anterior loop, a CBCT scan could be recommended when planning implant placement in the anterior region


Subject(s)
Humans , Cone-Beam Computed Tomography/methods , Radiography, Panoramic/methods , Dental Implantation/methods , Preoperative Care/methods , Tooth Apex/anatomy & histology
2.
Med Oral Patol Oral Cir Bucal ; 20(2): e239-45, 2015 Mar 01.
Article in English | MEDLINE | ID: mdl-25549693

ABSTRACT

OBJECTIVES: To compare the prevalence and the length of mental loop, measured with panoramic radiography (PR) and cone beam computerized tomography (CBCT). MATERIAL AND METHODS: PG and CBCT images where analyzed by a single calibrated examiner to determine the presence and the position of the mental foramen (MF), its distance to the lower mandible border, the anterior length of the mental loop (ML) and the bone quality in 82 PR and 82 CBCT. RESULTS: ML was identified in 36.6 % of PR and 48.8 % of CBCT. PR showed a magnification of 1.87 when compared to CBCT. The mean of anterior extension of the inferior alveolar nerve and the distance to the inferior border of the mandible was higher for PR (2.8 mm, sd 0.91 mm on the PR , range 1.5 to 4.7 mm and 1.59, sd 0.9 on the CBCT ,range 0.4 to 4.0 mm) CONCLUSIONS: There is a magnification in PR images with respect to those of CBCT. The differences between CBCT and PR with regards to the identification and length of the ML are not statistically significant. Identification and accuracy measurements of ML did not depend on the bone quality. Considering that two dimensional imaging provides less accurate and reliable information regarding the anterior loop, a CBCT scan could be recommended when planning implant placement in the anterior region.


Subject(s)
Cone-Beam Computed Tomography , Mandibular Nerve/diagnostic imaging , Radiography, Panoramic , Adolescent , Adult , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Retrospective Studies , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...