Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Eur Neuropsychopharmacol ; 26(4): 631-43, 2016 Apr.
Article in English | MEDLINE | ID: mdl-26951611

ABSTRACT

The relationship between stress response and positive affective states is thought to be bidirectional: whilst stress can lead to a blunted hedonic response, positive affect reduces the negative effects of stress. We have previously shown that persistently high positive affectivity as measured by 50-kHz ultrasonic vocalizations (USVs) is protective against chronic variable stress (CVS). The present study examined the effect of CVS on 50-kHz USVs elicited by amphetamine administration, simultaneously considering the stable inter-individual differences in positive affectivity. Forty juvenile male Wistar rats were categorised as of high (HC) or low (LC) positive affectivity based on their 50-kHz USV response to imitation of rough-and-tumble play ('tickling'). As adults, the rats were subjected to four weeks of CVS, after which D-amphetamine was administered in five daily doses followed by a challenge dose (all 1mg/kg IP) nine days later. CVS reduced sucrose preference in LC-rats only. After CVS, amphetamine-elicited 50-kHz USVs were significantly reduced in LC-rats, the effect of stress in HC-rats being smaller and less consistent. In previously stressed and amphetamine-treated LC-rats, locomotor response to amphetamine was attenuated. In stressed LC-rats, DOPAC levels and dopamine turnover were increased in striatum after amphetamine treatment, and dopamine D1 receptor levels were upregulated in nucleus accumbens. LC-rats had lower isoleucine levels in frontal cortex. These results show that stress-related changes in response to amphetamine are dependent on inter-individual differences in positive affectivity both at neurochemical and behavioural levels, and further support the notion of higher vulnerability of animals with low positive affect.


Subject(s)
Affect , Dextroamphetamine/pharmacology , Stress, Psychological/metabolism , Stress, Psychological/psychology , Vocalization, Animal/drug effects , Animals , Biogenic Monoamines/metabolism , Body Weight/drug effects , Dopamine/metabolism , Food Preferences/drug effects , Frontal Lobe/metabolism , Isoleucine/metabolism , Locomotion/drug effects , Male , Nucleus Accumbens/metabolism , Rats , Receptors, Dopamine D1/metabolism , Stereotyped Behavior/drug effects , Sucrose/pharmacology , Up-Regulation/drug effects
2.
J Chromatogr A ; 1317: 193-8, 2013 Nov 22.
Article in English | MEDLINE | ID: mdl-24011728

ABSTRACT

In this note the feasibility of a polyamine-based capillary coating, polyE-323, for capillary electrophoresis (CE) of lipids is explored. PolyE-323 has previously been demonstrated to be suitable to suppress analyte-wall interaction of proteins in CE. However, the full applicability range of polyE-323 has not been exploited yet and it might be useful in the analysis of hydrophobic analytes, such as lipids. In this study, the stability of polyE-323 when using highly organic background electrolytes (BGEs), which are needed to solubilize the lipid analytes, was studied. For this, we used three different lipid samples: sphingomyelin, cardiolipin and a lipid extract from a cell culture. The highly organic BGEs that were used in this study consisted of 94.5% of organic solvents and 5.5% of an aqueous buffer. First, the influence of pure acetonitrile, methanol, propylene carbonate, isopropanol and chloroform on the polyE-323 coating was investigated. Then BGEs were developed and tested, using sphingomyelin and cardiolipin as test analytes in CE-UV experiments. After establishing the best BGEs (in terms of analysis time and repeatability) by CE-UV, sphingomyelin was used as a test analyte to demonstrate that method was also suitable for CE with mass-spectrometry detection (CE-MS). The LOD of sphingomyelin was estimated to be 100 nM and its migration time repeatability was 1.3%. The CE-MS analysis was further applied on a lipid extract obtained from human glioblastoma cells, which resulted in the separation and detection of a multitude of putative lipids. The results of our feasibility study indicate that CE systems based on polyE-323 coated capillaries and highly organic BGEs are promising for fast electromigration-based analysis of lipids.


Subject(s)
Electrophoresis, Capillary/instrumentation , Lipids/analysis , Polyamines/chemistry , Electrophoresis, Capillary/methods , Limit of Detection , Lipids/isolation & purification , Organic Chemicals/chemistry , Reproducibility of Results , Solvents/chemistry
SELECTION OF CITATIONS
SEARCH DETAIL
...