Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Europace ; 23(1): 104-112, 2021 01 27.
Article in English | MEDLINE | ID: mdl-33083830

ABSTRACT

AIMS: Optimum timing of pacemaker implantation following cardiac surgery is a clinical challenge. European and American guidelines recommend observation, to assess recovery of atrioventricular block (AVB) (up to 7 days) and sinus node (5 days to weeks) after cardiac surgery. This study aims to determine rates of cardiac implantable electronic devices (CIEDs) implants post-surgery at a high-volume tertiary centre over 3 years. Implant timing, patient characteristics and outcomes at 6 months including pacemaker utilization were assessed. METHODS AND RESULTS: All cardiac operations (n = 5950) were screened for CIED implantation following surgery, during the same admission, from 2015 to 2018. Data collection included patient, operative, and device characteristics; pacing utilization and complications at 6 months. A total of 250 (4.2%) implants occurred; 232 (3.9%) for bradycardia. Advanced age, infective endocarditis, left ventricle systolic impairment, and valve surgery were independent predictors for CIED implants (P < 0.0001). Relative risk (RR) of CIED implants and proportion of AVB increased with valve numbers operated (single-triple) vs. non-valve surgery: RR 5.4 (95% CI 3.9-7.6)-21.0 (11.4-38.9) CIEDs. Follow-up pacing utilization data were available in 91%. Significant utilization occurred in 82% and underutilization (<1% A and V paced) in 18%. There were no significant differences comparing utilization rates in early (≤day 5 post-operatively) vs. late implants (P = 0.55). CONCLUSION: Multi-valve surgery has a particularly high incidence of CIED implants (14.9% double, 25.6% triple valve). Age, left ventricle systolic impairment, endocarditis, and valve surgery were independent predictors of CIED implants. Device underutilization was infrequent and uninfluenced by implant timing. Early implantation (≤5 days) should be considered in AVB post-multi-valve surgery.


Subject(s)
Cardiac Surgical Procedures , Defibrillators, Implantable , Pacemaker, Artificial , Cardiac Surgical Procedures/adverse effects , Defibrillators, Implantable/adverse effects , Electronics , Humans , Pacemaker, Artificial/adverse effects , Retrospective Studies , Risk Factors , Treatment Outcome
2.
Clin Case Rep ; 7(5): 857-860, 2019 May.
Article in English | MEDLINE | ID: mdl-31110703

ABSTRACT

All clinicians prescribing amiodarone require knowledge of the challenging diagnosis and management of amiodarone-induced pulmonary toxicity (APT), which is potentially fatal. APT should be considered early in all patients presenting with new respiratory symptoms and concurrent amiodarone therapy. Drug cessation and corticosteroid therapy can be highly effective once recognized.

SELECTION OF CITATIONS
SEARCH DETAIL
...