Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 14 de 14
Filter
1.
PLoS Negl Trop Dis ; 16(10): e0010657, 2022 10.
Article in English | MEDLINE | ID: mdl-36201428

ABSTRACT

The use of biomarkers to measure immune responses in serum is crucial for understanding population-level exposure and susceptibility to human pathogens. Advances in sample collection, multiplex testing, and computational modeling are transforming serosurveillance into a powerful tool for public health program design and response to infectious threats. In July 2018, 70 scientists from 16 countries met to perform a landscape analysis of approaches that support an integrated serosurveillance platform, including the consideration of issues for successful implementation. Here, we summarize the group's insights and proposed roadmap for implementation, including objectives, technical requirements, ethical issues, logistical considerations, and monitoring and evaluation.


Subject(s)
Communicable Diseases , Public Health , Biomarkers , Humans
2.
New Microbes New Infect ; 47: 100990, 2022.
Article in English | MEDLINE | ID: mdl-35747620

ABSTRACT

•Omicron variant continues to progress in Senegal with the appearance of new contaminations.•IRESSEF detected the first positive case of the Omicron variant on Friday, December 3, 2021.•Since this date, the number of Omicron variant infections has increased over the weeks.•Molecular surveillance of the Omicron variant allowed us to identify a strong variation of this variant in our country.

3.
J Mater Chem B ; 10(21): 4115, 2022 Jun 01.
Article in English | MEDLINE | ID: mdl-35608015

ABSTRACT

Correction for 'SARS-CoV-2 and approaches for a testing and diagnostic strategy' by Delyan R. Hristov et al., J. Mater. Chem. B, 2021, 9, 8157-8173, DOI: https://doi.org/10.1039/D1TB00674F.

4.
J Mater Chem B ; 9(39): 8157-8173, 2021 10 13.
Article in English | MEDLINE | ID: mdl-34494642

ABSTRACT

The COVID-19 pandemic has led to an unprecedented global health challenge, creating sudden, massive demands for diagnostic testing, treatment, therapies, and vaccines. In particular, the development of diagnostic assays for SARS-CoV-2 has been pursued as they are needed for quarantine, disease surveillance, and patient treatment. One of the major lessons the pandemic highlighted was the need for fast, cheap, scalable and reliable diagnostic methods, such as paper-based assays. Furthermore, it has previously been suggested that paper-based tests may be more suitable for settings with lower resource availability and may help alleviate some supply chain challenges which arose during the COVID-19 pandemic. Therefore, we explore how such devices may fit in a comprehensive diagnostic strategy and how some of the challenges to the technology, e.g. low sensitivity, may be addressed. We discuss the properties of the SARS-CoV-2 virus itself, the COVID-19 disease pathway, and the immune response. We then describe the different diagnostic strategies that have been pursued, focusing on molecular strategies for viral genetic material, antigen tests, and serological assays, and innovations for improving the diagnostic sensitivity and capabilities. Finally, we discuss pressing issues for the future, and what needs to be addressed for the ongoing pandemic and future outbreaks.


Subject(s)
COVID-19 Drug Treatment , COVID-19 Testing/methods , Animals , Humans , Pandemics , SARS-CoV-2
5.
Sci Immunol ; 5(47)2020 05 19.
Article in English | MEDLINE | ID: mdl-32430309

ABSTRACT

Serological testing for SARS-CoV-2 has enormous potential to contribute to COVID-19 pandemic response efforts. However, the required performance characteristics of antibody tests will critically depend on the use case (individual-level vs. population-level).


Subject(s)
Clinical Laboratory Techniques/methods , Antibodies, Viral/analysis , Betacoronavirus/immunology , COVID-19 , COVID-19 Testing , Coronavirus Infections/diagnosis , Coronavirus Infections/immunology , Epidemiological Monitoring , Humans , Pandemics , Pneumonia, Viral/immunology , SARS-CoV-2
6.
J Exp Med ; 217(7)2020 07 06.
Article in English | MEDLINE | ID: mdl-32413101

ABSTRACT

CMV is associated with immunosenescence and reduced vaccine responses in the elderly (>70 yr). However, the impact of CMV in young adults is less clear. In this study, healthy UK and Senegalese adults aged 18-50 yr (average, 29 yr) were vaccinated with the Ebola vaccine candidate chimpanzee adenovirus type 3-vectored Ebola Zaire vaccine (ChAd3-EBO-Z) and boosted with modified vaccinia Ankara Ebola Zaire-vectored (MVA-EBO-Z) vaccine. CMV carriage was associated with an expansion of phenotypically senescent CD4+ and CD8+ T cells expressing CD57 and killer cell lectin-like receptor G1 (KLRG1), which was negatively associated with vaccine responses in both cohorts. Ebola-specific T cell responses induced by vaccination also contained significantly increased frequencies of terminally differentiated CD57+KLRG1+ cells in CMV seropositive (CMV+) individuals. This study suggests that CMV can also affect vaccine responses in younger adults and may have a particularly marked impact in many developing countries where CMV seroprevalence is almost universal.


Subject(s)
CD57 Antigens/metabolism , Cytomegalovirus Infections/immunology , Ebola Vaccines/immunology , Lectins, C-Type/metabolism , Receptors, Immunologic/metabolism , T-Lymphocytes/immunology , Adult , CD4-Positive T-Lymphocytes/immunology , CD8-Positive T-Lymphocytes/immunology , Cell Differentiation , Cell Proliferation , Cellular Senescence , Cytomegalovirus Infections/virology , Humans , Immunologic Memory , Middle Aged , Phenotype , Seroepidemiologic Studies , Young Adult
7.
J Infect Dis ; 219(8): 1187-1197, 2019 04 08.
Article in English | MEDLINE | ID: mdl-30407513

ABSTRACT

BACKGROUND: The 2014 West African outbreak of Ebola virus disease highlighted the urgent need to develop an effective Ebola vaccine. METHODS: We undertook 2 phase 1 studies assessing safety and immunogenicity of the viral vector modified vaccinia Ankara virus vectored Ebola Zaire vaccine (MVA-EBO-Z), manufactured rapidly on a new duck cell line either alone or in a heterologous prime-boost regimen with recombinant chimpanzee adenovirus type 3 vectored Ebola Zaire vaccine (ChAd3-EBO-Z) followed by MVA-EBO-Z. Adult volunteers in the United Kingdom (n = 38) and Senegal (n = 40) were vaccinated and an accelerated 1-week prime-boost regimen was assessed in Senegal. Safety was assessed by active and passive collection of local and systemic adverse events. RESULTS: The standard and accelerated heterologous prime-boost regimens were well-tolerated and elicited potent cellular and humoral immunogenicity in the United Kingdom and Senegal, but vaccine-induced antibody responses were significantly lower in Senegal. Cellular immune responses measured by flow cytometry were significantly greater in African vaccinees receiving ChAd3 and MVA vaccines in the same rather than the contralateral limb. CONCLUSIONS: MVA biomanufactured on an immortalized duck cell line shows potential for very large-scale manufacturing with lower cost of goods. This first trial of MVA-EBO-Z in humans encourages further testing in phase 2 studies, with the 1-week prime-boost interval regimen appearing to be particularly suitable for outbreak control. CLINICAL TRIALS REGISTRATION: NCT02451891; NCT02485912.


Subject(s)
Ebola Vaccines/pharmacology , Adolescent , Adult , Ebola Vaccines/administration & dosage , Ebola Vaccines/adverse effects , Ebola Vaccines/immunology , Ebolavirus/immunology , Female , Humans , Immunization Schedule , Immunization, Secondary/adverse effects , Immunization, Secondary/methods , Male , Middle Aged , Senegal , United Kingdom , Young Adult
8.
Cytometry B Clin Cytom ; 92(6): 476-484, 2017 11.
Article in English | MEDLINE | ID: mdl-26917223

ABSTRACT

BACKGROUND: CD4 counts are currently used to assess HIV patients for treatment eligibility and to monitor antiretroviral response to treatment. The emerging point-of-care devices could fill an important gap in resource-limited settings. However, the accuracy of CD4-counting instruments is diverse and data on how CD4 measurement errors have an impact on clinical decisions are lacking. METHODS: Clinicians were queried on the use of CD4 results in their clinical setting. Subsequently, the effect of CD4 measurement errors on treatment initiation was put in a statistical model. Based on clinical CD4 databases from Belgium, Cambodia, and Senegal, the percentage of unchanged clinical decisions was calculated (treatment initiation should start within a 3-month delay [one visit]) for escalating CD4 measurement errors, taking into account the strict or preventive application of CD4 thresholds at 350 or 500 cells/µl used by clinicians. RESULTS: To ensure that the treatment was initiated appropriately for at least 95% of patients, an error of 5 - 10 cells/µl was allowed. This is significantly smaller than the bias of ±50 cells/µl most clinicians considered acceptable. For limits of agreement (LOA, 1.96 x error) of 100 cells/µl, corresponding to most CD4 instrument evaluations, the misclassification rate of patients was found to be 3 - 28% at the threshold of 350 cells/µl (strict or flexible), and 13 - 20% at 500 cells/µl. CONCLUSIONS: The maximum allowed CD4 bias on results from new CD4 technologies should not exceed 50 cells/µl (LOA 100 cells/µl) when applied for treatment initiation, to ensure at least 72% of correct clinical decisions. © 2016 International Clinical Cytometry Society.


Subject(s)
Anti-HIV Agents/therapeutic use , CD4 Lymphocyte Count/statistics & numerical data , CD4-Positive T-Lymphocytes/immunology , Clinical Decision-Making , HIV Infections/drug therapy , Adult , Belgium , Bias , CD4-Positive T-Lymphocytes/virology , Cambodia , Female , Flow Cytometry/instrumentation , Flow Cytometry/standards , HIV/drug effects , HIV/immunology , HIV Infections/diagnosis , HIV Infections/immunology , HIV Infections/virology , Humans , Immunophenotyping , Male , Middle Aged , Point-of-Care Testing , Practice Guidelines as Topic , Senegal , Sensitivity and Specificity , Time-to-Treatment
9.
PLoS One ; 10(2): e0116663, 2015.
Article in English | MEDLINE | ID: mdl-25688553

ABSTRACT

BACKGROUND: A new CD4 point-of-care instrument, the CyFlow miniPOC, which provides absolute and percentage CD4 T-cells, used for screening and monitoring of HIV-infected patients in resource-limited settings, was introduced recently. We assessed the performance of this novel instrument in a reference laboratory and in a field setting in Senegal. METHODOLOGY: A total of 321 blood samples were obtained from 297 adults and 24 children, all HIV-patients attending university hospitals in Dakar, or health centers in Ziguinchor. Samples were analyzed in parallel on CyFlow miniPOC, FACSCount CD4 and FACSCalibur to assess CyFlow miniPOC precision and accuracy. RESULTS: At the reference lab, CyFlow miniPOC, compared to FACSCalibur, showed an absolute mean bias of -12.6 cells/mm3 and a corresponding relative mean bias of -2.3% for absolute CD4 counts. For CD4 percentages, the absolute mean bias was -0.1%. Compared to FACSCount CD4, the absolute and relative mean biases were -31.2 cells/mm3 and -4.7%, respectively, for CD4 counts, whereas the absolute mean bias for CD4 percentages was 1.3%. The CyFlow miniPOC was able to classify HIV-patients eligible for ART with a sensitivity of ≥ 95% at the different ART-initiation thresholds (200, 350 and 500 CD4 cells/mm3). In the field lab, the room temperature ranged from 30 to 35°C during the working hours. At those temperatures, the CyFlow miniPOC, compared to FACSCount CD4, had an absolute and relative mean bias of 7.6 cells/mm3 and 2.8%, respectively, for absolute CD4 counts, and an absolute mean bias of 0.4% for CD4 percentages. The CyFlow miniPOC showed sensitivity equal or greater than 94%. CONCLUSION: The CyFlow miniPOC showed high agreement with FACSCalibur and FACSCount CD4. The CyFlow miniPOC provides both reliable absolute CD4 counts and CD4 percentages even under the field conditions, and is suitable for monitoring HIV-infected patients in resource-limited settings.


Subject(s)
CD4 Lymphocyte Count/methods , Flow Cytometry/methods , Point-of-Care Systems , Adolescent , Adult , Aged , Antiretroviral Therapy, Highly Active , Child , Child, Preschool , Female , Flow Cytometry/instrumentation , HIV Infections/blood , HIV Infections/drug therapy , Humans , Infant , Male , Middle Aged , Reproducibility of Results , Senegal , Young Adult
10.
J Acquir Immune Defic Syndr ; 66(5): e98-107, 2014 Aug 15.
Article in English | MEDLINE | ID: mdl-24853304

ABSTRACT

BACKGROUND: CD4⁺ T-cell counts are used to screen and follow-up HIV-infected patients during treatment. As part of the World Health Organization prequalification program of diagnostics, we conducted an independent multicenter evaluation of the FACSCount CD4 and the Pima CD4, using the FACSCalibur as reference method. METHODS: A total of 440 paired capillary and venous blood samples were collected from HIV-infected patients attending the HIV outpatient clinic in Antwerp, Belgium, and the HIV care and treatment center in Dar es Salam, Tanzania. Capillary blood was run on Pima analyzer, whereas venous blood was analyzed on FACSCount, Pima, and FACSCalibur instruments. Precision and agreement between methods were assessed. RESULTS: The FACSCount CD4 results were in agreement with the FACSCalibur results with relative bias of 0.4% and 3.1% on absolute CD4 counts and an absolute bias of -0.6% and -1.1% on CD4% in Antwerp and Dar es Salam, respectively. The Pima CD4 results were in agreement with the FACSCalibur results with relative bias of -4.1% and -9.4% using venous blood and of -9.5% and -0.9% using capillary blood in Antwerp and Dar es Salam, respectively. At the threshold of 350 cells per microliter, the FACSCount CD4 and Pima CD4 using venous and capillary blood misclassified 7%, 9%, and 13% of patients, respectively. CONCLUSIONS: The FACSCount CD4 provides reliable CD4 counts and CD4% and is suitable for monitoring adult and pediatric HIV patients in moderate-volume settings. The Pima CD4 is more suitable for screening eligible adult HIV patients for antiretroviral treatment initiation in low-volume laboratories.


Subject(s)
CD4 Lymphocyte Count/instrumentation , CD4 Lymphocyte Count/methods , HIV Infections/blood , HIV Infections/diagnosis , Adult , Aged , Aged, 80 and over , Belgium/epidemiology , Female , HIV Infections/epidemiology , Humans , Male , Middle Aged , Sensitivity and Specificity , Tanzania/epidemiology , Young Adult
11.
PLoS One ; 8(9): e75484, 2013.
Article in English | MEDLINE | ID: mdl-24066184

ABSTRACT

BACKGROUND: Flow Cytometry (FCM) is still considered to be the method of choice for accurate CD4 enumeration. However, the use of FCM in developing countries is problematic due to their cost and complexity. Lower-cost technologies have been introduced. We evaluated CyFlow Counter together with its lyophilized reagents, and Pima CD4 in high-temperature area, using FACSCount as reference. MATERIALS AND METHODS: Whole blood samples were consecutively collected by venipuncture from 111 HIV+ patients and 17 HIV-negative donors. CD4 T-cell enumeration was performed on CyFlow Counter, Pima CD4 and FACSCount. RESULTS: CyFlow Counter and Pima CD4 systems showed good correlation with FACSCount (slope of 0.82 and 0.90, and concordance ρc of 0.94 and 0.98, respectively). CyFlow Counter showed absolute or relative biases (LOA) of -63 cells/mm(3) (-245 to 120) or -9.8% (-38.1 to 18.4) respectively, and Pima CD4 showed biases (LOA) of -30 cells/mm(3) (-160 to 101) or -3.5% (-41.0 to 33.9%). CyFlow Counter and Pima CD4 showed respectively 106.7% and 105.9% of similarity with FACSCount. According to WHO-2010 ART initiation threshold of 350 cells/mm(3), CyFlow Counter and Pima CD4 showed respectively sensibility of 100% and 97%, and specificity of 91% and 93%. CyFlow Counter and Pima CD4 were strongly correlated (slope of 1.09 and ρc of 0.95). These alternative systems showed good agreement with bias of 33 cells/mm(3) (-132 to 203) or 6.3% (-31.2 to 43.8), and similarity of 104.3%. CONCLUSION: CyFlow Counter using CD4 easy count kit-dry and Pima CD4 systems can accurately provide CD4 T-cell counts with acceptable agreement to those of FACSCount.


Subject(s)
CD4-Positive T-Lymphocytes/metabolism , Adolescent , Adult , Aged , CD4 Lymphocyte Count , Cells, Cultured , Child , Female , Flow Cytometry , Humans , Male , Middle Aged , Young Adult
12.
Afr J Lab Med ; 2(1): 76, 2013.
Article in English | MEDLINE | ID: mdl-29043167

ABSTRACT

BACKGROUND: Tuberculosis (TB) has been shown to accelerate the clinical course of HIV infection, but the mechanisms by which this occurs are not well understood. Regulatory T-cells (Tregs) are known to dampen hyperactivation of the immune cells, but it remains unclear whether hyperactivation of T-cells in HIV infection is associated with a decrease of Tregs and what the effect Mycobacterium tuberculosis (MTB) co-infection has on T-cell activation and Tregs. OBJECTIVES: In this study, we aim to evaluate whether active TB is associated with the increased expression of T-cell activation markers and reduced number of Treg cells in HIV-1-infected patients. METHODS: This study was conducted on 69 subjects consisting of 20 HIV-infected patients, 20 HIV and MTB co-infected patients, 19 MTB-infected patients and 10 uninfected control subjects negative for both MTB and HIV. The frequencies of T-cell activation markers (CD38 and HLA-DR) and Treg cells (CD4+CD25+CD127-) were measured by flow cytometry. RESULTS: Significantly higher expression of CD38 and HLA-DR on CD4+ and CD8+ T-cells was found in MTB and HIV co-infected patients compared with HIV-infected patients. However, no significant difference in the percentage of Treg cells was reported between HIV patients with TB and those without. The study also showed a negative correlation between regulatory T-cells frequency and CD4+ T-cell counts. CONCLUSION: These results suggest that TB enhances the expression of peripheral T-cell activation markers during HIV infection, whilst having no impact on the percentages of Treg cells.

13.
J Acquir Immune Defic Syndr ; 58(4): e103-11, 2011 Dec 01.
Article in English | MEDLINE | ID: mdl-21909029

ABSTRACT

BACKGROUND: CD4(+) T-cell enumeration (CD4 count) is used as a criterion to initiate antiretroviral therapy (ART) in HIV patients and to monitor treatment efficacy. However, simple, affordable, and reliable point-of-care (POC) instruments adapted to resource-limited settings are still lacking. The PIMA CD4 analyzer is a new POC instrument for CD4 counting that uses disposable cartridges and a battery-powered analyzer. METHODS: Whole blood samples were taken by venipuncture or by finger prick from 300 subjects, including HIV-infected patients and HIV (-) controls. CD4 counts were measured by PIMA (using venous or capillary blood) and by FACSCount (using venous blood) considered as the reference. RESULTS: Similar CD4 counts were obtained by PIMA and FACSCount using either HIV+ venous blood or HIV+ finger-prick blood samples. However, with a concordance coefficient of 0.88 and a Pearson correlation of 0.89, finger-prick blood performed not as good as venous blood (0.97 and 0.98, respectively). For a clinical decision to start ART at 200 CD4 cells per microliter, sensitivity of PIMA was 90%/91% and specificity 98%/96% for venous/finger-prick blood, respectively, and for a treatment threshold of 350 CD4 cells per microliter, the sensitivity was 98%/91% and the specificity was 79%/80% for venous/finger-prick blood, respectively. Repeatability (precision) on venous blood resulted in a coefficient of variation of 4%. Using finger-prick blood, the average instrument error frequency resulting in aborted analyses was 14%. CONCLUSIONS: PIMA is a good POC instrument for screening adult HIV-infected patients in resource-limited settings for treatment eligibility. Its performance on finger-prick blood is not as good as on venous blood. Adequate training for correct use of finger-prick blood samples is mandatory.


Subject(s)
CD4 Lymphocyte Count/instrumentation , HIV Infections/diagnosis , Mass Screening/instrumentation , Adult , CD4 Lymphocyte Count/methods , Female , HIV Infections/blood , Humans , Male , Mass Screening/methods , Middle Aged , Reproducibility of Results , Sensitivity and Specificity
14.
J Immunol Methods ; 372(1-2): 7-13, 2011 Sep 30.
Article in English | MEDLINE | ID: mdl-21835181

ABSTRACT

Laboratory follow-up of HIV patients in resource-limited settings requires appropriate instruments for CD4 T cell enumeration. In this study, we evaluated the application of a simplified, mobile and robust flow cytometry system, the Apogee Auto 40 analyzer (Auto40) using thermoresistant reagents, for CD4 T cell enumeration. We measured the absolute CD4 counts in fresh whole blood samples from 170 Senegalese subjects, including 129 HIV-positive (HIV+) patients and 41 HIV-negative (HIV-) controls. Based on volumetric primary CD4 gating, cells were stained with commercially available reagents (Easy MoAb CD4;Bio-D, Valenzano, Italy) and analyzed on the Auto40. The results were compared with those from the FACSCount system (Becton Dickinson, San Jose, USA). Repeatability analysis was performed on duplicate testing of 49 samples on both FACSCount and Auto40. The intra-run precision was measured by 10 replicates using 3 clinical blood samples with low, intermediate and high CD4 concentrations. The results from the two instruments were in good agreement. The percent similarity between the results of both instruments was 99%±relative standard deviation of 12.7%. The concordance correlation coefficient was 0.99. The absolute bias and limits of agreement (LOA) between the two instruments, calculated by Bland-Altman analysis, were clinically acceptable (bias: +4 cells/µl; LOA: -111 to +120 cells/µl). The clinical agreement between the two instruments at a cutoff of 200 CD4 cells/µl was 94%. The repeatability of measurements on the Auto40 was also similar to that observed with FACSCount system (bias +0.1 cells/µl, coefficient of variation 2.5% vs bias -1.1cells/µl, coefficient of variation 2.9% respectively). In conclusion, our results indicate that the Auto 40 system, using thermoresistant reagents, is suitable for CD4 T cell enumeration and will be a helpful tool to improve HIV laboratory monitoring in resource-limited settings.


Subject(s)
CD4 Lymphocyte Count/standards , CD4-Positive T-Lymphocytes/immunology , Flow Cytometry/standards , HIV Infections/immunology , HIV/immunology , CD4 Lymphocyte Count/methods , CD4-Positive T-Lymphocytes/cytology , CD4-Positive T-Lymphocytes/virology , Flow Cytometry/instrumentation , Flow Cytometry/methods , HIV Infections/blood , HIV Infections/virology , Humans , Indicators and Reagents/standards , Regression Analysis , Reproducibility of Results , Senegal
SELECTION OF CITATIONS
SEARCH DETAIL
...