Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Radiat Oncol ; 9: 46, 2014 Feb 05.
Article in English | MEDLINE | ID: mdl-24499602

ABSTRACT

PURPOSE: Intrafraction motion during step-and-shoot (SNS) IMRT is known to affect the target dosimetry by a combination of dose blurring and interplay effects. These effects are typically managed by adding a margin around the target. A quantitative analysis was performed, assessing the relationship between target motion, margin size, and target dosimetry with the goal of introducing new margin recipes. METHODS: A computational algorithm was used to calculate 1,174 motion-encoded dose distributions and DVHs within the patient's CT dataset. Sinusoidal motion tracks were used simulating intrafraction motion for nine lung tumor patients, each with multiple margin sizes. RESULTS: D95% decreased by less than 3% when the maximum target displacement beyond the margin experienced motion less than 5 mm in the superior-inferior direction and 15 mm in the anterior-posterior direction. For target displacements greater than this, D95% decreased rapidly. CONCLUSIONS: Targets moving in excess of 5 mm outside the margin can cause significant changes to the target. D95% decreased by up to 20% with target motion 10 mm outside the margin, with underdosing primarily limited to the target periphery. Multi-fractionated treatments were found to exacerbate target under-coverage. Margins several millimeters smaller than the maximum target displacement provided acceptable motion protection, while also allowing for reduced normal tissue morbidity.


Subject(s)
Algorithms , Lung Neoplasms/radiotherapy , Motion , Radiotherapy Planning, Computer-Assisted , Radiotherapy, Intensity-Modulated , Humans , Lung Neoplasms/pathology , Radiometry , Radiotherapy Dosage , Radiotherapy, Image-Guided , Tumor Burden
2.
Int J Radiat Oncol Biol Phys ; 86(3): 477-83, 2013 Jul 01.
Article in English | MEDLINE | ID: mdl-23523325

ABSTRACT

PURPOSE: To describe the first use of the commercially available Calypso 4D Localization System in the lung. METHODS AND MATERIALS: Under an institutional review board-approved protocol and an investigational device exemption from the US Food and Drug Administration, the Calypso system was used with nonclinical methods to acquire real-time 4-dimensional lung tumor tracks for 7 lung cancer patients. The aims of the study were to investigate (1) the potential for bronchoscopic implantation; (2) the stability of smooth-surface beacon transponders (transponders) after implantation; and (3) the ability to acquire tracking information within the lung. Electromagnetic tracking was not used for any clinical decision making and could only be performed before any radiation delivery in a research setting. All motion tracks for each patient were reviewed, and values of the average displacement, amplitude of motion, period, and associated correlation to a sinusoidal model (R(2)) were tabulated for all 42 tracks. RESULTS: For all 7 patients at least 1 transponder was successfully implanted. To assist in securing the transponder at the tumor site, it was necessary to implant a secondary fiducial for most transponders owing to the transponder's smooth surface. For 3 patients, insertion into the lung proved difficult, with only 1 transponder remaining fixed during implantation. One patient developed a pneumothorax after implantation of the secondary fiducial. Once implanted, 13 of 14 transponders remained stable within the lung and were successfully tracked with the tracking system. CONCLUSIONS: Our initial experience with electromagnetic guidance within the lung demonstrates that transponder implantation and tracking is achievable though not clinically available. This research investigation proved that lung tumor motion exhibits large variations from fraction to fraction within a single patient and that improvements to both transponder and tracking system are still necessary to create a clinical daily-use system to assist with actual lung radiation therapy.


Subject(s)
Electromagnetic Fields , Fiducial Markers , Lung Neoplasms , Lung , Movement , Robotics/methods , Bronchoscopy , Fiducial Markers/adverse effects , Humans , Implants, Experimental , Lung/diagnostic imaging , Lung Neoplasms/diagnostic imaging , Pneumothorax/etiology , Prostheses and Implants , Radiography
SELECTION OF CITATIONS
SEARCH DETAIL
...