1.
Arch Orthop Trauma Surg ; 144(5): 1997-2006, 2024 May.
Article in English | MEDLINE | ID: mdl-38570357

ABSTRACT

BACKGROUND: This study aimed to meta-analyze epidemiological data, revision rates, and incidences of different designs of a single Total Knee Arthroplasty System and compare these factors across different countries. METHODS: A systematic review was conducted on clinical studies and arthroplasty registries of ATTUNE TKA from 1999 to 2020. The main endpoints analyzed were revision rates and epidemiological data. RESULTS: The average age of patients was 67.8 years, with a gender distribution of 60% female and 40% male. The pooled average BMI was 29.4 kg/m2. Eight clinical studies showed a pooled revision rate per 100 observed CY of 0.5 (n = 1343 cases). Cumulative revision rates after 1, 3, and 5 years varied among registries, with the Swiss registry having the highest revision data (after 5 years: 6.3%) and the American registry having the lowest revision data (after 5 years: 1.7%). A comparison of the revision rates of mobile bearing and fixed bearing (41,200 cases) as well as cruciate retaining and posterior stabilized (n = 123,361 cases) showed no significant advantage in the first 5 years after implantation. CONCLUSION: In conclusion, pooled data from 41,200 cases of TKA with a single Total Knee Arthroplasty System in two arthroplasty registries revealed that there was no significant difference in revision rates between the mobile bearing and fixed bearing design within the first 5 years after implantation. In addition, a comparison of the revision rates in n = 123,361 cases showed no significant advantage for cruciate retaining or posterior stabilized in the first 5 years after implantation.


Subject(s)
Arthroplasty, Replacement, Knee , Knee Prosthesis , Prosthesis Design , Registries , Reoperation , Humans , Arthroplasty, Replacement, Knee/statistics & numerical data , Arthroplasty, Replacement, Knee/methods , Reoperation/statistics & numerical data , Male , Female , Prosthesis Failure , Clinical Trials as Topic/statistics & numerical data , Aged
2.
Front Cardiovasc Med ; 10: 1305649, 2023.
Article in English | MEDLINE | ID: mdl-38099228

ABSTRACT

Aim: The purpose of this study was to investigate the clinical application of Compressed SENSE accelerated single-breath-hold LGE with 3D isotropic resolution compared to conventional LGE imaging acquired in multiple breath-holds. Material & Methods: This was a retrospective, single-center study including 105 examinations of 101 patients (48.2 ± 16.8 years, 47 females). All patients underwent conventional breath-hold and 3D single-breath-hold (0.96 × 0.96 × 1.1 mm3 reconstructed voxel size, Compressed SENSE factor 6.5) LGE sequences at 1.5 T in clinical routine for the evaluation of ischemic or non-ischemic cardiomyopathies. Two radiologists independently evaluated the left ventricle (LV) for the presence of hyperenhancing lesions in each sequence, including localization and transmural extent, while assessing their scar edge sharpness (SES). Confidence of LGE assessment, image quality (IQ), and artifacts were also rated. The impact of LV ejection fraction (LVEF), heart rate, body mass index (BMI), and gender as possible confounders on IQ, artifacts, and confidence of LGE assessment was evaluated employing ordinal logistic regression analysis. Results: Using 3D single-breath-hold LGE readers detected more hyperenhancing lesions compared to conventional breath-hold LGE (n = 246 vs. n = 216 of 1,785 analyzed segments, 13.8% vs. 12.1%; p < 0.0001), pronounced at subendocardial, midmyocardial, and subepicardial localizations and for 1%-50% of transmural extent. SES was rated superior in 3D single-breath-hold LGE (4.1 ± 0.8 vs. 3.3 ± 0.8; p < 0.001). 3D single-breath-hold LGE yielded more artifacts (3.8 ± 1.0 vs. 4.0 ± 3.8; p = 0.002) whereas IQ (4.1 ± 1.0 vs. 4.2 ± 0.9; p = 0.122) and confidence of LGE assessment (4.3 ± 0.9 vs. 4.3 ± 0.8; p = 0.374) were comparable between both techniques. Female gender negatively influenced artifacts in 3D single-breath-hold LGE (p = 0.0028) while increased heart rate led to decreased IQ in conventional breath-hold LGE (p = 0.0029). Conclusions: In clinical routine, Compressed SENSE accelerated 3D single-breath-hold LGE yields image quality and confidence of LGE assessment comparable to conventional breath-hold LGE while providing improved delineation of smaller LGE lesions with superior scar edge sharpness. Given the fast acquisition of 3D single-breath-hold LGE, the technique holds potential to drastically reduce the examination time of CMR.

3.
iScience ; 25(7): 104504, 2022 Jul 15.
Article in English | MEDLINE | ID: mdl-35754733

ABSTRACT

The origin, composition, distribution, and function of cells in the human intervertebral disc (IVD) have not been fully understood. Here, cell atlases of both human neonatal and adult IVDs have been generated and further assessed by gene ontology pathway enrichment, pseudo-time trajectory, histology, and immunofluorescence. Comparison of cell atlases revealed the presence of two subpopulations of notochordal cells (NCs) and their associated markers in both the neonatal and adult IVDs. Developmental trajectories predicted 7 different cell states that describe the developmental process from neonatal to adult cells in IVD and analyzed the NC's role in the IVD development. A high heterogeneity and gradual transition of annulus fibrosus cells (AFCs) in the neonatal IVD was detected and their potential relevance in IVD development assessed. Collectively, comparing single-cell atlases between neonatal and adult IVDs delineates the landscape of IVD cell biology and may help discover novel therapeutic targets for IVD degeneration.

4.
Clin Neuroradiol ; 31(3): 815-826, 2021 Sep.
Article in English | MEDLINE | ID: mdl-33026511

ABSTRACT

PURPOSE: To evaluate a novel flow-independent 3D isotropic REACT sequence compared with CE-MRA for the imaging of extracranial arteries in acute ischemic stroke (AIS). METHODS: This was a retrospective study of 35 patients who underwent a stroke protocol at 3 T including REACT (fixed scan time: 2:46 min) and CE-MRA of the extracranial arteries. Three radiologists evaluated scans regarding vessel delineation, signal, and contrast and assessed overall image noise and artifacts using 5-point scales (5: excellent delineation/no artifacts). Apparent signal- and contrast-to-noise ratios (aSNR/aCNR) were measured for the common carotid artery (CCA), internal carotid artery (ICA, C1 segment), and vertebral artery (V2 segment). Two radiologists graded the degree of proximal ICA stenosis. RESULTS: Compared to REACT, CE-MRA showed better delineation for the CCA and ICA (C1 and C2 segments) (median 5, range 2-5 vs. 4, range 3-5; P < 0.05). For the ICA (C1 and C2 segments), REACT provided a higher signal (5, range 3-5; P < 0.05/4.5, range 3-5; P > 0.05 vs. 4, range 2-5) and contrast (5, range 3-5 vs. 4, range 2-5; P > 0.05) than CE-MRA. The remaining segments of the blood-supplying vessels showed equal medians. There was no significant difference regarding artifacts, whereas REACT provided significantly lower image noise (4, range 3-5 vs. 4 range 2-5; P < 0.05) with a higher aSNR (P < 0.05) and aCNR (P < 0.05) for all vessels combined. For clinically relevant (≥50%) ICA stenosis, REACT achieved a detection sensitivity of 93.75% and a specificity of 100%. CONCLUSION: Given its fast acquisition, comparable image quality to CE-MRA and high sensitivity and specificity for the detection of ICA stenosis, REACT was proven to be a clinically applicable method to assess extracranial arteries in AIS.


Subject(s)
Brain Ischemia , Ischemic Stroke , Stroke , Brain Ischemia/diagnostic imaging , Carotid Arteries , Contrast Media , Humans , Magnetic Resonance Angiography , Retrospective Studies , Sensitivity and Specificity , Stroke/diagnostic imaging
5.
Int J Cardiovasc Imaging ; 37(1): 315-329, 2021 Jan.
Article in English | MEDLINE | ID: mdl-32852711

ABSTRACT

To compare a novel Compressed SENSE accelerated ECG- and respiratory-triggered flow-independent 3D isotropic Relaxation-Enhanced Angiography without Contrast and Triggering (modified REACT) with standard non-ECG-triggered 3D contrast-enhanced magnetic resonance angiography (CE-MRA) for imaging of the thoracic aorta in patients with connective tissue diseases (CTD) or other aortic diseases using manual and semiautomatic measurement approaches. This retrospective, single-center analysis of 30 patients (June-December 2018) was conducted by two radiologists, who independently measured aortic diameters on modified REACT and CE-MRA using manual (Multiplanar-Reconstruction) and semiautomatic (Advanced Vessel Analysis) measurement tools on seven levels (inner edge): Aortic annulus and sinus, sinotubular junction, mid- and high-ascending aorta, aortic isthmus, and descending aorta. Bland-Altman analysis was conducted to evaluate differences between the mean values of aortic width and ICCs were calculated to assess interobserver agreement. For each level, image quality was evaluated on a four-point scale in consensus with Wilcoxon matched-pair test used to evaluate for differences between both MRA techniques. Additionally, evaluation time for each measurement technique was noted, which was compared applying one-way ANOVA. When comparing both imaging and measurement methods, CE-MRA (mean difference 0.24 ± 0.27 mm) and the AVA-tool (- 0.21 ± 0.15 mm) yielded higher differences compared to modified REACT (- 0.11 ± 0.11 mm) and the MPR-tool (0.07 ± 0.21 mm) for all measurement levels combined without yielding clinical significance. There was an excellent interobserver agreement between modified REACT and CE-MRA using both tools of measurement (ICC > 0.9). Modified REACT (average acquisition time 06:34 ± 01:36 min) provided better image quality from aortic annulus to mid-ascending aorta (p < 0.05), whereas at distal measurement levels, no significant differences were noted. Regarding time requirement, no statistical significance was found between both measurement techniques (p = 0.08). As a novel non-CE-MRA technique, modified REACT allows for fast imaging of the thoracic aorta with higher image quality in the proximal aorta than CE-MRA enabling a reliable measurement of vessel dimensions without the need for contrast agent. Thus, it represents a clinically suitable alternative for patients requiring repetitive imaging. Manual and semiautomatic measurement approaches provided comparable results without significant difference in time need.


Subject(s)
Aorta, Thoracic/diagnostic imaging , Aortic Diseases/diagnostic imaging , Cardiac-Gated Imaging Techniques , Connective Tissue Diseases/diagnostic imaging , Imaging, Three-Dimensional , Magnetic Resonance Angiography , Magnetic Resonance Imaging, Cine , Adult , Contrast Media , Databases, Factual , Electrocardiography , Female , Humans , Male , Middle Aged , Observer Variation , Organometallic Compounds , Predictive Value of Tests , Reproducibility of Results , Retrospective Studies
6.
J Cardiovasc Magn Reson ; 22(1): 89, 2020 12 17.
Article in English | MEDLINE | ID: mdl-33327958

ABSTRACT

BACKGROUND: Late gadolinium enhancement (LGE) cardiovascular magnetic resonance (CMR) represents the gold standard for assessment of myocardial viability. The purpose of this study was to investigate the clinical potential of Compressed SENSE (factor 5) accelerated free-breathing three-dimensional (3D) whole heart LGE with high isotropic spatial resolution (1.4 mm3 acquired voxel size) compared to standard breath-hold LGE imaging. METHODS: This was a retrospective, single-center study of 70 consecutive patients (45.8 ± 18.1 years, 27 females; February-November 2019), who were referred for assessment of left ventricular myocardial viability and received free-breathing and breath-hold LGE sequences at 1.5 T in clinical routine. Two radiologists independently evaluated global and segmental LGE in terms of localization and transmural extent. Readers scored scans regarding image quality (IQ), artifacts, and diagnostic confidence (DC) using 5-point scales (1 non-diagnostic-5 excellent/none). Effects of heart rate and body mass index (BMI) on IQ, artifacts, and DC were evaluated with ordinal logistic regression analysis. RESULTS: Global LGE (n = 33) was identical for both techniques. Using free-breathing LGE (average scan time: 04:33 ± 01:17 min), readers detected more hyperenhanced lesions (28.2% vs. 23.5%, P < .05) compared to breath-hold LGE (05:15 ± 01:23 min, P = .0104), pronounced at subepicardial localization and for 1-50% of transmural extent. For free-breathing LGE, readers graded scans with good/excellent IQ in 80.0%, with low-impact/no artifacts in 78.6%, and with good/high DC in 82.1% of cases. Elevated BMI was associated with increased artifacts (P = .0012) and decreased IQ (P = .0237). Increased heart rate negatively influenced artifacts (P = .0013) and DC (P = .0479) whereas IQ (P = .3025) was unimpaired. CONCLUSIONS: In a clinical setting, free-breathing Compressed SENSE accelerated 3D high isotropic spatial resolution whole heart LGE provides good to excellent image quality in 80% of scans independent of heart rate while enabling improved depiction of small and particularly non-ischemic hyperenhanced lesions in a shorter scan time than standard breath-hold LGE.


Subject(s)
Cardiomyopathies/diagnostic imaging , Contrast Media , Heart Ventricles/diagnostic imaging , Imaging, Three-Dimensional , Magnetic Resonance Imaging, Cine , Myocardium/pathology , Organometallic Compounds , Adolescent , Adult , Aged , Aged, 80 and over , Cardiomyopathies/pathology , Databases, Factual , Female , Heart Ventricles/pathology , Humans , Male , Middle Aged , Observer Variation , Predictive Value of Tests , Reproducibility of Results , Retrospective Studies , Tissue Survival , Young Adult
7.
Eur Radiol ; 30(7): 3968-3976, 2020 Jul.
Article in English | MEDLINE | ID: mdl-32125516

ABSTRACT

OBJECTIVES: Peritoneal carcinomatosis (PC) is a prognostically relevant metastatic disease which may be difficult to depict in postoperative patients, particularly in early stages. This study aimed to determine whether PC could be diagnosed more accurately when using a combination of spectral detector CT (SDCT)-derived conventional images (CI) and iodine overlay images (IO) compared with CI only. METHODS: Thirty patients with PC and 30 patients with benign peritoneal alterations (BPA) who underwent portal-venous abdominal SDCT were included. Four radiologists determined the presence/absence of PC for each patient and assessed lesion conspicuity, diagnostic certainty, and image quality using 5-point Likert scales. Subjective assessment was conducted in two sessions comprising solely CI and CI/IO between which a latency of 6 weeks was set. Iodine uptake and HU attenuation were determined ROI-based to analyze quantitative differentiation of PC/BPA. RESULTS: Specificity for PC was significantly higher when using CI/IO compared with using CI only (0.86 vs. 0.78, p ≤ 0.05), while sensitivity was comparable (0.79 vs. 0.81, p = 1). In postoperative patients, the increase in specificity was the highest (0.93 vs. 0.80, p ≤ 0.05). Lesion conspicuity was rated higher in CI/IO (4 (3-5)) compared with that in CI only (3 (3-4); p ≤ 0.05). Diagnostic certainty was comparable (both 4 (3-5); p = 0.5). CI/IO received the highest rating for overall image quality and assessability (CI/IO 5 (4-5) vs. CI 4 (4-4) vs. IO 4 (3-4); p ≤ 0.05). Area under the receiver operating characteristics curve (AUC) for quantitative differentiation between PC and BPA was higher for iodine (AUCIodine = 0.95, AUCHU = 0.90). CONCLUSIONS: Compared with CI, combination of CI/IO improves specificity in the assessment of peritoneal carcinomatosis at comparable sensitivity, particularly in postoperative patients. KEY POINTS: • Combination of iodine overlays and conventional images improves specificity when assessing patients with peritoneal carcinomatosis at comparable sensitivity. • Particularly in postsurgical patients, iodine overlays could help to avoid false-positive diagnosis of peritoneal disease. • Iodine overlays alone provided inferior image quality and assessability than conventional images, while the combination of both received the highest ratings. Iodine overlays should therefore be used in addition to and not as a substitute for conventional images.


Subject(s)
Iodine/metabolism , Peritoneal Neoplasms/diagnosis , Peritoneum/diagnostic imaging , Tomography, X-Ray Computed/methods , Aged , Diagnosis, Differential , Female , Humans , Male , Middle Aged , Portal Vein , ROC Curve
8.
J Cardiovasc Magn Reson ; 22(1): 16, 2020 Feb 21.
Article in English | MEDLINE | ID: mdl-32085782

ABSTRACT

The original publication of this article [1], contained graphical errors in Figs. 1 and 2. This does not impact the display of the mean differences of the Bland-Altman plots. The updated figures (Fig. 1 and Fig. 2) are published in this correction article.

9.
J Cardiovasc Magn Reson ; 22(1): 8, 2020 01 23.
Article in English | MEDLINE | ID: mdl-31969137

ABSTRACT

BACKGROUND: Patients with Congenital heart disease (CHD) require repetitive imaging of the pulmonary vasculature throughout their life. In this study, we compared a novel Compressed SENSE accelerated (factor 9) electrocardiogram (ECG)- and respiratory-triggered 3D modified Relaxation-Enhanced Angiography without Contrast and Triggering (modified REACT-non-contrast-enhanced magnetic resonance angiography (modified REACT-non-CE-MRA)) with standard non-ECG-triggered time-resolved 4D CE-MRA for imaging of the pulmonary arteries and veins in patients with CHD. METHODS: This retrospective analysis of 25 patients (June 2018-April 2019) with known or suspected CHD was independently conducted by two radiologists executing measurements on modified REACT-non-CE-MRA and 4D CE-MRA on seven dedicated points (inner edge): Main pulmonary artery (MPA), right and left pulmonary artery, right superior and inferior pulmonary vein, left superior (LSPV) and inferior pulmonary vein. Image quality for arteries and veins was evaluated on a four-point scale in consensus. RESULTS: Twenty-three of the 25 included patients presented a CHD. There was a high interobserver agreement for both methods of imaging at the pulmonary arteries (ICC ≥ 0.96); at the pulmonary veins, modified REACT-non-CE-MRA showed a slightly higher agreement, pronounced at LSPV (ICC 0.946 vs. 0.895). Measurements in 4D CE-MRA showed higher diameter values compared to modified REACT-non-CE-MRA, at the pulmonary arteries reaching significant difference (e.g. MPA: mean 0.408 mm, p = 0.002). Modified REACT-non-CE-MRA (average acquisition time 07:01 ± 02:44 min) showed significant better image quality than 4D CE-MRA at the pulmonary arteries (3.84 vs. 3.32, p < 0.001) and veins (3.32 vs. 2.72, p = 0.015). CONCLUSIONS: Compressed SENSE accelerated (factor 9) ECG- and respiratory-triggered 3D modified REACT-non-CE-MRA allows for reliable and fast imaging of the pulmonary arteries and veins with higher image quality and slightly higher interobserver agreement than 4D CE-MRA without contrast agent and associated disadvantages. Therefore, it represents a clinically suitable technique for patients requiring repetitive imaging of the pulmonary vasculature, e.g. patients with CHD.


Subject(s)
Cardiac-Gated Imaging Techniques , Heart Defects, Congenital/diagnostic imaging , Image Interpretation, Computer-Assisted , Magnetic Resonance Angiography , Pulmonary Artery/diagnostic imaging , Pulmonary Veins/diagnostic imaging , Adult , Databases, Factual , Electrocardiography , Female , Humans , Male , Middle Aged , Observer Variation , Predictive Value of Tests , Reproducibility of Results , Retrospective Studies , Young Adult
10.
Eur J Radiol ; 121: 108733, 2019 Dec.
Article in English | MEDLINE | ID: mdl-31739270

ABSTRACT

PURPOSE: CT artifacts from port-systems are a common problem in staging- and restaging-examinations and reduce image quality and diagnostic assessment. The purpose of this study was to investigate the reduction of these artifacts using virtual monoenergetic images (VMI) from dual-energy spectral-detector CT (SDCT) in comparison to conventional CT-images (CI). METHOD: 50 SDCT-datasets of patients with artifacts from port-chamber and port-catheters were included in this IRB-approved, retrospective study. CI and VMI (range, 40-200 keV, 10 keV increment) were reconstructed from the same acquisition. The quantitative image analysis was performed ROI-based assessing mean and standard deviation of attenuation (HU) in most pronounced hypo- and hyperdense artifacts surrounding to the port-chamber and the distal end of the port-catheter in the superior vena cava. Subjectively, artifact reduction and diagnostic assessment of surrounding soft tissue were rated on 5-point Likert-scales. RESULTS: In comparison to CI, VMI of higher keV-values showed strong reduction of hypo- and hyperattenuating artifacts around the port-chamber and port-catheter (CI/VMI200keV: hypodense -104.7 ±â€¯124.7HU/10.8 ±â€¯58.1HU and -101.6 ±â€¯101.5HU/-36.7 ±â€¯32.9HU; hyperdense 240.8 ±â€¯151.6HU/79.6 ±â€¯81.3HU and 108.6 ±â€¯129.3HU/25.9 ±â€¯31.9HU; all p < 0.001). Image noise could also be reduced significantly. The subjective analysis showed significantly reduced artifacts around the port-chamber and port-catheter (CI/VMI200keV: hypodense 3(1-4)/5(4-5) and 3(2-4)/5(4-5); hyperdense 3(1-4)/5(4-5) and 3(2-3)/5(3-5); all p < 0.001) and improved diagnostic assessment of pectoral/subclavian soft tissue for VMI of ≥100keV. Ratings for diagnostic assessment were best between 140-200 keV. Overall interrater agreement was high (ICC = 0.79). CONCLUSIONS: Higher keV VMI enabled a significant reduction of artifacts from port-systems around the chamber and the catheter leading to improved assessment of surrounding soft tissue.


Subject(s)
Artifacts , Image Processing, Computer-Assisted/methods , Tomography, X-Ray Computed/methods , Vascular Access Devices , Adult , Female , Humans , Male , Middle Aged , Retrospective Studies , Signal-To-Noise Ratio
11.
Kidney Int ; 96(1): 80-93, 2019 07.
Article in English | MEDLINE | ID: mdl-31029503

ABSTRACT

Beside the classical flat parietal epithelial cells (PECs), we investigated proximal tubular epithelial-like cells, a neglected subgroup of PECs. These cells, termed cuboidal PECs, make up the most proximal part of the proximal tubule and may also line parts of Bowman's capsule. Additionally, a third intermediate PEC subgroup was identified at the junction between the flat and cuboidal PEC subgroups at the tubular orifice. The transgenic mouse line PEC-rtTA labeled all three PEC subgroups. Here we show that the inducible Pax8-rtTA mouse line specifically labeled only cuboidal and intermediate PECs, but not flat PECs. In aging Pax8-rtTA mice, cell fate mapping showed no evidence for significant transdifferentiation from flat PECs to cuboidal or intermediate PECs or vice versa. In murine glomerular disease models of crescentic glomerulonephritis, and focal segmental glomerulosclerosis (FSGS), intermediate PECs became more numerous. These intermediate PECs preferentially expressed activation markers CD44 and Ki-67, suggesting that this subgroup of PECs was activated more easily than the classical flat PECs. In mice with FSGS, cuboidal and intermediate PECs formed sclerotic lesions. In patients with FSGS, cells forming the tip lesions expressed markers of intermediate PECs. These novel PEC subgroups form sclerotic lesions and were more prone to cellular activation compared to the classical flat PECs in disease. Thus, colonization of Bowman's capsule by cuboidal PECs may predispose to lesion formation and chronic kidney disease. We propose that tip lesions originate from this novel subgroup of PECs in patients with FSGS.


Subject(s)
Epithelial Cells/pathology , Glomerulosclerosis, Focal Segmental/pathology , Kidney Glomerulus/pathology , Kidney Tubules, Proximal/cytology , Adolescent , Adult , Aged , Aged, 80 and over , Animals , Bowman Capsule/cytology , Disease Models, Animal , Epithelial Cells/metabolism , Female , Humans , Hyaluronan Receptors/metabolism , Ki-67 Antigen/metabolism , Male , Mice , Mice, Transgenic , Middle Aged , PAX8 Transcription Factor/genetics , Young Adult