Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Main subject
Language
Publication year range
1.
Sensors (Basel) ; 23(5)2023 Feb 23.
Article in English | MEDLINE | ID: mdl-36904658

ABSTRACT

In this article, we propose an evolved system design approach to ultra-wideband (UWB) radar based on pseudo-random noise (PRN) sequences, the key features of which are its user-adaptability to meet the demands provided by desired microwave imaging applications and its multichannel scalability. In light of providing a fully synchronized multichannel radar imaging system for short-range imaging as mine detection, non-destructive testing (NDT) or medical imaging, the advanced system architecture is presented with a special focus put on the implemented synchronization mechanism and clocking scheme. The core of the targeted adaptivity is provided by means of hardware, such as variable clock generators and dividers as well as programmable PRN generators. In addition to adaptive hardware, the customization of signal processing is feasible within an extensive open-source framework using the Red Pitaya® data acquisition platform. A system benchmark in terms of signal-to-noise ratio (SNR), jitter, and synchronization stability is conducted to determine the achievable performance of the prototype system put into practice. Furthermore, an outlook on the planned future development and performance improvement is provided.

2.
Article in English | MEDLINE | ID: mdl-34057891

ABSTRACT

In ultrasound nondestructive testing (NDT), a widespread approach is to take synthetic aperture measurements from the surface of a specimen to detect and locate defects within it. Based on these measurements, imaging is usually performed using the synthetic aperture focusing technique (SAFT). However, SAFT is suboptimal in terms of resolution and requires oversampling in the time domain to obtain a fine grid for the delay-and-sum (DAS). On the other hand, parametric reconstruction algorithms give better resolution, but their usage for imaging becomes computationally expensive due to the size of the parameter space and a large amount of measurement data in realistic 3-D scenarios when using oversampling. In the literature, the remedies to this are twofold. First, the amount of measurement data can be reduced using state-of-the-art sub-Nyquist sampling approaches to measure Fourier coefficients instead of time-domain samples. Second, parametric reconstruction algorithms mostly rely on matrix-vector operations that can be implemented efficiently by exploiting the underlying structure of the model. In this article, we propose and compare different strategies to choose the Fourier coefficients to be measured. Their asymptotic performance is compared by numerically evaluating the Cramér-Rao bound (CRB) for the localizability of the defect coordinates. These subsampling strategies are then combined with an l1 -minimization scheme to compute 3-D reconstructions from the low-rate measurements. Compared to conventional DAS, this allows us to formulate a fully physically motivated forward model matrix. To enable this, the projection operations of the forward model matrix are implemented matrix-free by exploiting the underlying two-level Toeplitz structure. Finally, we show that high-resolution reconstructions from as low as a single Fourier coefficient per A-scan are possible based on simulated data and measurements from a steel specimen.


Subject(s)
Algorithms , Fourier Analysis , Ultrasonography
SELECTION OF CITATIONS
SEARCH DETAIL
...