Pediatr Diabetes ; 17(5): 311-8, 2016 08.
Article in English | MEDLINE | ID: mdl-26073672

ABSTRACT

BACKGROUND: The relationship between frequency and sustained bolus advisor (BA) use and glycemic improvement has not been well characterized in pediatric populations. OBJECTIVE: The objective of this study is to assess the impact of frequent and persistent BA use on glycemic control among pediatric type 1 diabetes patients. METHODS: In this 6-month, single-center, retrospective cohort study, 104 children [61 girls, mean age: 12.7 yr, mean HbA1c 8.0 (1.6)% [64 (17.5) mmol/mol]], treated with the Accu-Chek Aviva Combo insulin pump, were observed. Frequency of BA use, HbA1c, hypoglycemia (<70 mg/dL), therapy changes, mean blood glucose, and glycemic variability (standard deviation) was assessed at baseline and month 6. Sub-analyses of the adolescent patient use (12 months) and longitudinal use (24 months) were also conducted. RESULTS: Seventy-one patients reported high frequency (HF) device use (≥50%); 33 reported low frequency (LF) use (<50%) during the study. HF users achieved lower mean (SE) HbA1c levels than LF users: 7.5 (0.1)% [59 (1.1) mmol/mol] vs. 8.0 (0.2)% [64 (2.2) mmol/mol], p = 0.0252. No between-group differences in the percentage of hypoglycemia values were seen at 6 months. HF users showed less glycemic variability (84.0 vs. 94.7, p = 0.0045) than LF users. More HF patients reached HbA1c target of <7.5 at 6 months 66.2% (+16.9) vs. 27.3% (-9.1), p = 0.0056. Similar HbA1c results were seen in adolescents and BA users at 24 months. CONCLUSION: Frequent use of the Accu-Chek Aviva Combo insulin pump BA feature was associated with improved and sustained glycemic control with no increase in hypoglycemia in this pediatric population.


Subject(s)
Blood Glucose , Diabetes Mellitus, Type 1/drug therapy , Hypoglycemic Agents/administration & dosage , Infusion Pumps, Implantable , Insulin/administration & dosage , Adolescent , Child , Child, Preschool , Female , Humans , Longitudinal Studies , Male , Retrospective Studies
3.
Diabetes Technol Ther ; 16(5): 310-6, 2014 May.
Article in English | MEDLINE | ID: mdl-24716820

ABSTRACT

BACKGROUND: We assessed the impact of using an automated bolus advisor integrated into a blood glucose meter on the timing and frequency of adjusting insulin therapy parameter settings and whether the availability of this technology would increase blood glucose test strip utilization in diabetes patients treated with multiple daily insulin injection (MDI) therapy. SUBJECTS AND METHODS: The Automated Bolus Advisor Control and Usability Study (ABACUS) trial, a 26-week, prospective, randomized, controlled, multinational study that enrolled 218 type 1 and type 2 diabetes patients, demonstrated that use of an automated insulin bolus advisor helps improve glycemic control in suboptimally controlled, MDI-treated patients. Patient data were assessed to determine when and how often changes in insulin parameter settings occurred during the study. Patient meters were downloaded to determine blood glucose monitoring frequency. RESULTS: One hundred ninety-three patients completed the study: 93 control arm (CNL) and 100 intervention (experimental) arm (EXP). Significantly more EXP (47.5%) than CNL (30.7%) patients received one or more changes in their insulin sensitivity factor (ISF) settings during the study (P=0.0191). Changes in ISF settings occurred earlier and more frequently in EXP than CNL patients throughout the study. A similar trend was seen in changes in insulin-to-carbohydrate ratios. There were no differences in daily self-monitoring of blood glucose frequency [mean (SD)] between CNL and EXP patients: 4.7 (1.5) versus 4.6 (1.3) (P=0.4085). CONCLUSIONS: Use of an automated bolus advisor was associated with earlier, more frequent changes in key insulin parameters, which may have contributed to subsequent improvements in glycemic control but without increased glucose test strip utilization.


Subject(s)
Blood Glucose Self-Monitoring/methods , Blood Glucose/analysis , Diabetes Mellitus, Type 1/drug therapy , Diabetes Mellitus, Type 2/drug therapy , Hypoglycemic Agents/administration & dosage , Insulin/administration & dosage , Adolescent , Adult , Blood Glucose Self-Monitoring/instrumentation , Chi-Square Distribution , Diabetes Mellitus, Type 1/blood , Diabetes Mellitus, Type 2/blood , Drug Administration Schedule , Female , Glycated Hemoglobin/analysis , Humans , Male , Prospective Studies , Young Adult
4.
Diabetes Care ; 36(11): 3613-9, 2013 Nov.
Article in English | MEDLINE | ID: mdl-23900590

ABSTRACT

OBJECTIVE: Use of automated bolus advisors is associated with improved glycemic control in patients treated with insulin pump therapy. We conducted a study to assess the impact of using an insulin bolus advisor embedded in a blood glucose (BG) meter on glycemic control and treatment satisfaction in patients treated with multiple daily insulin injection (MDI) therapy. The study goal was to achieve >0.5% A1C reduction in most patients. RESEARCH DESIGN AND METHODS: This was a 26-week, prospective, randomized, controlled, multinational study that enrolled 218 MDI-treated patients with poorly controlled diabetes (202 with type 1 diabetes, 16 with type 2 diabetes) who were 18 years of age or older. Participants had mean baseline A1C of 8.9% (SD, 1.2 [74 mmol/mol]), mean age of 42.4 years (SD, 14.0), mean BMI of 26.5 kg/m(2) (SD, 4.2), and mean diabetes duration of 17.7 years (SD, 11.1). Control group (CNL) patients used a standard BG meter and manual bolus calculation; intervention group (EXP) patients used the Accu-Chek Aviva Expert meter with an integrated bolus advisor to calculate insulin dosages. Glucose data were downloaded and used for therapy parameter adjustments in both groups. RESULTS: A total of 193 patients (CNL, n = 93; EXP, n = 100) completed the study. Significantly more EXP than CNL patients achieved >0.5% A1C reduction (56.0% vs. 34.4%; P < 0.01). Improvement in treatment satisfaction (Diabetes Treatment Satisfaction Questionnaire scale) was significantly greater in EXP patients (11.4 [SD, 6.0] vs. 9.0 [SD, 6.3]; P < 0.01). Percentage of BG values <50 mg/dL was <2% in both groups during the study. CONCLUSIONS: Use of an automated bolus advisor resulted in improved glycemic control and treatment satisfaction without increasing severe hypoglycemia.


Subject(s)
Blood Glucose/drug effects , Diabetes Mellitus, Type 1/drug therapy , Diabetes Mellitus, Type 2/drug therapy , Hypoglycemic Agents/therapeutic use , Insulin/administration & dosage , Adolescent , Adult , Blood Glucose/analysis , Blood Glucose Self-Monitoring/methods , Female , Humans , Hypoglycemia/drug therapy , Insulin Infusion Systems , Male , Prospective Studies , Young Adult
5.
BMC Fam Pract ; 13: 102, 2012 Oct 13.
Article in English | MEDLINE | ID: mdl-23062116

ABSTRACT

BACKGROUND: People with T1DM and insulin-treated T2DM often do not follow and/or adjust their insulin regimens as needed. Key contributors to treatment non-adherence are fear of hypoglycaemia, difficulty and lack of self-efficacy associated with insulin dose determination. Because manual calculation of insulin boluses is both complex and time consuming, people may rely on empirical estimates, which can result in persistent hypoglycaemia and/or hyperglycaemia. Use of automated bolus advisors (BA) has been shown to help insulin pump users to more accurately meet prandial insulin dosage requirements, improve postprandial glycaemic excursions, and achieve optimal glycaemic control with an increased time within optimal range. Use of a BA containing an early algorithm based on sliding scales for insulin dosing has also been shown to improve HbA1c levels in people treated with multiple daily insulin injections (MDI). We designed a study to determine if use of an automated BA can improve clinical and psychosocial outcomes in people treated with MDI. METHODS/DESIGN: The Automated Bolus Advisor Control and Usability Study (ABACUS) is a 6-month, prospective, randomised, multi-centre, multi-national trial to determine if automated BA use improves glycaemic control as measured by a change in HbA1c in people using MDI with elevated HbA1c levels (#62;7.5%). A total of 226 T1DM and T2DM participants will be recruited. Anticipated attrition of 20% will yield a sample size of 90 participants, which will provide #62;80% power to detect a mean difference of 0.5%, with SD of 0.9%, using a one-sided 5% t-test, with 5% significance level. Other measures of glycaemic control, self-care behaviours and psychosocial issues will also be assessed. DISCUSSION: It is critical that healthcare providers utilise available technologies that both facilitate effective glucose management and address concerns about safety and lifestyle. Automated BAs may help people using MDI to manage their diabetes more effectively and minimise the risk of long-term diabetes related complications. Findings from a recent study suggest that BA use positively addresses both safety and lifestyle concerns; however, randomised trials are needed to confirm these perceptions and determine whether bolus advisor use improves clinical outcomes. Our study is designed to make these assessments. TRIAL REGISTRATION: NCT01460446.


Subject(s)
Algorithms , Diabetes Mellitus, Type 1/drug therapy , Diabetes Mellitus, Type 2/drug therapy , Drug Dosage Calculations , Glycated Hemoglobin/analysis , Hypoglycemic Agents/administration & dosage , Insulin/administration & dosage , Humans , Hyperglycemia/prevention & control , Hypoglycemia/prevention & control , Medication Adherence , Patient Satisfaction , Prospective Studies , Self Care , Treatment Outcome
7.
Diabetes Care ; 35(4): 693-8, 2012 Apr.
Article in English | MEDLINE | ID: mdl-22344611

ABSTRACT

OBJECTIVE: We evaluated the impact of an automated decision support tool (DST) on clinicians' ability to identify glycemic abnormalities in structured self-monitoring of blood glucose (SMBG) data and then make appropriate therapeutic changes based on the glycemic patterns observed. RESEARCH DESIGN AND METHODS: In this prospective, randomized, controlled, multicenter study, 288 clinicians (39.6% family practice physicians, 37.9% general internal medicine physicians, and 22.6% nurse practitioners) were randomized to structured SMBG alone (STG; n = 72); structured SMBG with DST (DST; n = 72); structured SMBG with an educational DVD (DVD; n = 72); and structured SMBG with DST and the educational DVD (DST+DVD; n = 72). Clinicians analyzed 30 patient cases (type 2 diabetes), identified the primary abnormality, and selected the most appropriate therapy. RESULTS: A total of 222 clinicians completed all 30 patient cases with no major protocol deviations. Significantly more DST, DVD, and DST+DVD clinicians correctly identified the glycemic abnormality and selected the most appropriate therapeutic option compared with STG clinicians: 49, 51, and 55%, respectively, vs. 33% (all P < 0.0001) with no significant differences among DST, DVD, and DST+DVD clinicians. CONCLUSIONS: Use of structured SMBG, combined with the DST, the educational DVD, or both, enhances clinicians' ability to correctly identify significant glycemic patterns and make appropriate therapeutic decisions to address those patterns. Structured testing interventions using either the educational DVD or the DST are equally effective in improving data interpretation and utilization. The DST provides a viable alternative when comprehensive education is not feasible, and it may be integrated into medical practices with minimal training.


Subject(s)
Algorithms , Data Interpretation, Statistical , Decision Support Systems, Clinical/standards , Decision Support Techniques , Diabetes Mellitus, Type 2/blood , Adult , Aged , Automation , Blood Glucose/analysis , Blood Glucose Self-Monitoring/instrumentation , Blood Glucose Self-Monitoring/methods , Blood Glucose Self-Monitoring/statistics & numerical data , Calibration , Clinical Competence , Decision Making/physiology , Decision Support Systems, Clinical/statistics & numerical data , Diabetes Mellitus, Type 2/diagnosis , Diabetes Mellitus, Type 2/therapy , Female , Humans , Male , Middle Aged
8.
Diabetes Res Clin Pract ; 96(2): 149-55, 2012 May.
Article in English | MEDLINE | ID: mdl-22265215

ABSTRACT

INTRODUCTION: Patients with T2DM often view self-monitoring of blood glucose (SMBG) as burdensome and pointless, which may affect their broader attitudes toward diabetes management. We examined how a structured SMBG protocol influenced diabetes self-efficacy and autonomous motivation over time, and linked these to changes in glycemic control. MATERIALS AND METHODS: The Structured Testing Program (STeP) is a 12-month, two-arm, cluster-randomized trial that assessed the efficacy of structured SMBG in 483 insulin-naïve T2DM patients. Measures included: Confidence in Diabetes Self-Care for Type 2 patients (CIDS-T2), Diabetes-related Autonomous Motivation (DRAM), self-management behaviors and HbA1c. RESULTS: Intent-to-treat (ITT) and per-protocol (PP) analyses showed significant increases in CIDS-T2 scores over time (main effects p<0.0001). PP analysis showed significant between-group differences (p<0.05), with adherent STG patients displaying greater CIDS-T2 improvement than ACG patients. PP analyses showed main and between-group effects in DRAM with similar findings. Changes in CIDS-T2 were related to HbA1c changes over time; no self-management variable mediated this relationship. CIDS-T2 and HbA1c displayed a significant time-concordant relationship. DISCUSSION: Structured SMBG leads to significant increases in self-confidence and autonomous motivation associated with diabetes self-management. Changes in self-confidence are linked to changes in glycemic control and share a time-concordant relationship.


Subject(s)
Blood Glucose Self-Monitoring/psychology , Diabetes Mellitus, Type 2/drug therapy , Diabetes Mellitus, Type 2/psychology , Hypoglycemic Agents/therapeutic use , Insulin/therapeutic use , Self Care/psychology , Aged , Diabetes Mellitus, Type 2/blood , Disease Management , Female , Humans , Male , Middle Aged
9.
Diabetes Technol Ther ; 13(8): 797-802, 2011 Aug.
Article in English | MEDLINE | ID: mdl-21568751

ABSTRACT

BACKGROUND: We evaluated how a structured patient/physician self-monitoring of blood glucose (SMBG) intervention influenced the timing, frequency, and effectiveness of primary care physicians' treatment changes with type 2 diabetes mellitus (T2DM) patients over 12 months. METHODS: The Structured Testing Program (STeP) study was a cluster-randomized, multicenter trial with 483 poorly controlled, insulin-naive T2DM subjects. Primary care practices were randomized to the Active Control Group (ACG) or the Structured Testing Group (STG), the latter of which included quarterly review of structured SMBG results. STG patients used a paper tool that graphs seven-point glucose profiles over 3 consecutive days; physicians received a treatment algorithm based on SMBG patterns. Impact of structured SMBG on physician treatment modification recommendations (TMRs) and glycemic outcomes was examined. RESULTS: More STG than ACG patients received a TMR at each study visit (P < 0.0001). Of patients who received at least one TMR, STG patients demonstrated a greater reduction in glycated hemoglobin A1c (HbA1c) than ACG patients (-1.2% vs. -0.8%, P < 0.03). Patients with a baseline HbA1c ≥8.5% who received a TMR at the Month 1 visit experienced greater reductions in HbA1c (P = 0.002) than patients without an initial TMR. More STG than ACG patients were started on incretins (P < 0.01) and on thiazolidinediones (P = 0.004). The number of visits with a TMR was unrelated to HbA1c change over time. CONCLUSIONS: Patient-provided SMBG data contribute to glycemic improvement when blood glucose patterns are easy to detect, and well-trained physicians take timely action. Collaborative use of structured SMBG data leads to earlier, more frequent, and more effective TMRs for poorly controlled, non-insulin-treated T2DM subjects.


Subject(s)
Blood Glucose Self-Monitoring/methods , Diabetes Mellitus, Type 2/blood , Hypoglycemic Agents/administration & dosage , Incretins/administration & dosage , Thiazolidinediones/administration & dosage , Blood Glucose Self-Monitoring/standards , Diabetes Mellitus, Type 2/drug therapy , Female , Glycated Hemoglobin/metabolism , Humans , Linear Models , Male , Middle Aged , Physicians, Primary Care
10.
Diabetes Care ; 34(2): 262-7, 2011 Feb.
Article in English | MEDLINE | ID: mdl-21270183

ABSTRACT

OBJECTIVE: To assess the effectiveness of structured blood glucose testing in poorly controlled, noninsulin-treated type 2 diabetes. RESEARCH DESIGN AND METHODS: This 12-month, prospective, cluster-randomized, multicenter study recruited 483 poorly controlled (A1C ≥ 7.5%), insulin-naïve type 2 diabetic subjects from 34 primary care practices in the U.S. Practices were randomized to an active control group (ACG) with enhanced usual care or a structured testing group (STG) with enhanced usual care and at least quarterly use of structured self-monitoring of blood glucose (SMBG). STG patients and physicians were trained to use a paper tool to collect/interpret 7-point glucose profiles over 3 consecutive days. The primary end point was A1C level measured at 12 months. RESULTS: The 12-month intent-to-treat analysis (ACG, n = 227; STG, n = 256) showed significantly greater reductions in mean (SE) A1C in the STG compared with the ACG: -1.2% (0.09) vs. -0.9% (0.10); Δ = -0.3%; P = 0.04. Per protocol analysis (ACG, n = 161; STG, n = 130) showed even greater mean (SE) A1C reductions in the STG compared with the ACG: -1.3% (0.11) vs. -0.8% (0.11); Δ = -0.5%; P < 0.003. Significantly more STG patients received a treatment change recommendation at the month 1 visit compared with ACG patients, regardless of the patient's initial baseline A1C level: 179 (75.5%) vs. 61 (28.0%); <0.0001. Both STG and ACG patients displayed significant (P < 0.0001) improvements in general well-being (GWB). CONCLUSIONS: Appropriate use of structured SMBG significantly improves glycemic control and facilitates more timely/aggressive treatment changes in noninsulin-treated type 2 diabetes without decreasing GWB.


Subject(s)
Blood Glucose Self-Monitoring/methods , Diabetes Mellitus, Type 2/diagnosis , Diabetes Mellitus, Type 2/drug therapy , Glycated Hemoglobin/metabolism , Hypoglycemic Agents/therapeutic use , Adult , Aged , Blood Glucose/drug effects , Female , Humans , Male , Middle Aged , Patient Education as Topic/methods , Patient Participation , Primary Health Care , Prospective Studies
11.
Diabetes Technol Ther ; 11(5): 283-91, 2009 May.
Article in English | MEDLINE | ID: mdl-19425876

ABSTRACT

BACKGROUND: The purpose of this study was to determine if primary care physicians could utilize data collection tools to accurately identify glycemic abnormalities in structured, episodic self-monitoring of blood glucose (SMBG) data from patients with non-insulin-treated type 2 diabetes and whether use of these SMBG data would influence their therapeutic decisions. METHODS: Twenty-three case studies demonstrating several glycemic states (normoglycemia, elevated fasting glucose, elevated postprandial glucose, all elevated glucose, and hypoglycemia) were presented to 61 primary care physicians who evaluated the cases based upon A1C data, alone and then in combination with SMBG data. SMBG data were presented in five formats. Participants were to identify the specific glucose pattern, determine the necessity for therapy change, and select specific therapeutic changes. Participant assessments were compared with assessments made by a panel of diabetes care specialists. RESULTS: Most (78%) participants identified the same primary blood glucose feature identified by the diabetes specialists; 93.8% agreed with the diabetes care specialists regarding the need for therapy modification. The majority (77%) of participants changed the way they would manage the case after evaluating case studies with SMBG data made available to them. Eighty-six percent of participants considered the SMBG data to be of equal value or more valuable than an A1C test result; 71% of participants strongly agreed that they are now more likely to recommend structured, episodic SMBG to their non-insulin-treated type 2 diabetes mellitus patients. CONCLUSIONS: Primary care physicians can correctly identify glycemic abnormalities in SMBG data obtained through structured, episodic SMBG. Additional studies are needed to determine the clinical impact of similar testing regimens in primary care practice settings.


Subject(s)
Blood Glucose Self-Monitoring/psychology , Diabetes Mellitus, Type 2/blood , Physician-Patient Relations , Adult , Diabetes Mellitus, Type 2/rehabilitation , Educational Status , Fasting , Female , Glycated Hemoglobin/analysis , Humans , Hyperglycemia/epidemiology , Male , Middle Aged , Patient Education as Topic , Physicians, Family , Postprandial Period , Self Care , Surveys and Questionnaires