Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters










Database
Language
Publication year range
1.
Opt Express ; 24(24): 27753-27762, 2016 Nov 28.
Article in English | MEDLINE | ID: mdl-27906343

ABSTRACT

We present an improved, single-distance phase retrieval algorithm applicable for holographic X-ray imaging of biological objects for an in-line germanium Bragg Magnifier Microscope (BMM). The proposed algorithm takes advantage of a modified shrink-wrap algorithm for phase objects, robust unwrapping algorithm as well as other reasonable constraints applied to the wavefield at the object and the detector plane. The performance of the algorithm is analyzed on phantom objects and the results are shown and discussed. We demonstrated the suitability of the algorithm for the phase retrieval on a more complex biological specimen Tardigrade, where we achieved successful phase retrieval from only a single hologram. The spatial resolution obtained by Fourier spectral power method for biological objects is ∼ 300 nm, the same value as obtained from the reconstructed test pattern. Our results achieved using the new algorithm confirmed the potential of BMM for in-vivo, dose-efficient single-shot imaging of biological objects.

2.
Phys Med ; 32(12): 1759-1764, 2016 Dec.
Article in English | MEDLINE | ID: mdl-27836637

ABSTRACT

PURPOSE: Edge illumination (EI) X-ray phase-contrast imaging (XPCI) has been under development at University College London in recent years, and has shown great potential for both laboratory and synchrotron applications. In this work, we propose a new acquisition and processing scheme. Contrary to existing retrieval methods for EI, which require as input two images acquired in different setup configurations, the proposed approach can retrieve an approximate map of the X-ray phase from a single image, thus significantly simplifying the acquisition procedure and reducing data collection times. METHODS: The retrieval method is analytically derived, based on the assumption of a quasi-homogeneous object, i.e. an object featuring a constant ratio between refractive index and absorption coefficient. The noise properties of the input and retrieved images are also theoretically analyzed under the developed formalism. The method is applied to experimental synchrotron images of a biological object. RESULTS: The experimental results show that the method can provide high-quality images, where the "edge" signal typical of XPCI images is transformed to an "area" contrast that enables an easier interpretation of the sample geometry. Moreover, the retrieved images confirm that the method is highly stable against noise. CONCLUSIONS: We anticipate that the developed approach will become the method of choice for a variety of applications of EI XPCI, thanks to its ability to simplify the acquisition procedure and reduce acquisitions time and dose to the sample. Future work will focus on the adaptation of the method to computed tomography and to polychromatic radiation from X-ray tubes.


Subject(s)
Lighting , Radiography/instrumentation , Signal-To-Noise Ratio , Image Processing, Computer-Assisted , Synchrotrons , Wood , X-Rays
3.
Soft Matter ; 12(1): 171-80, 2016 Jan 07.
Article in English | MEDLINE | ID: mdl-26451659

ABSTRACT

Structural distortion and relaxation are central to any liquid flow. Their full understanding requires simultaneous probing of the mechanical as well as structural and dynamical response. We provide the first full dynamical measurement of the transient structure using combined coherent X-ray scattering and rheology on electrostatically interacting colloidal fluids. We find a stress overshoot during the start-up of shear which is due to the strong anisotropic overstretching and compression of nearest-neighbor distances. The rheological response is reflected in uncorrelated entropy-driven intensity fluctuations. While the structural distortion under steady shear is well described by Smoluchowski theory, we find an increase of the particle dynamics beyond the trivial contribution of flow. After the cessation of shear, the full fluid microstructure and dynamics are restored, both on the structural relaxation timescale. We thus find unique structure-dynamics relations in liquid flow, responsible for the macroscopic rheological behavior of the system.

4.
Sci Rep ; 5: 16318, 2015 Nov 06.
Article in English | MEDLINE | ID: mdl-26541117

ABSTRACT

We present a development of the beam-tracking approach that allows its implementation in computed tomography. One absorbing mask placed before the sample and a high resolution detector are used to track variations in the beam intensity distribution caused by the sample. Absorption, refraction, and dark-field are retrieved through a multi-Gaussian interpolation of the beam. Standard filtered back projection is used to reconstruct three dimensional maps of the real and imaginary part of the refractive index, and of the dark-field signal. While the method is here demonstrated using synchrotron radiation, its low coherence requirements suggest a possible implementation with laboratory sources.

5.
J Synchrotron Radiat ; 22(4): 1072-7, 2015 Jul.
Article in English | MEDLINE | ID: mdl-26134813

ABSTRACT

A method is proposed which enables the retrieval of the thickness or of the projected electron density of a sample from a single input image acquired with an edge illumination phase-contrast imaging setup. The method assumes the case of a quasi-homogeneous sample, i.e. a sample with a constant ratio between the real and imaginary parts of its complex refractive index. Compared with current methods based on combining two edge illumination images acquired in different configurations of the setup, this new approach presents advantages in terms of simplicity of acquisition procedure and shorter data collection time, which are very important especially for applications such as computed tomography and dynamical imaging. Furthermore, the fact that phase information is directly extracted, instead of its derivative, can enable a simpler image interpretation and be beneficial for subsequent processing such as segmentation. The method is first theoretically derived and its conditions of applicability defined. Quantitative accuracy in the case of homogeneous objects as well as enhanced image quality for the imaging of complex biological samples are demonstrated through experiments at two synchrotron radiation facilities. The large range of applicability, the robustness against noise and the need for only one input image suggest a high potential for investigations in various research subjects.

6.
Opt Express ; 22(14): 17281-91, 2014 Jul 14.
Article in English | MEDLINE | ID: mdl-25090542

ABSTRACT

Ptychographic techniques are currently the subject of increasing scientific interest due to their capability to retrieve the complex transmission function of an object at very high resolution. However, they impose a substantial burden in terms of acquisition time and dimension of the scanned area, which limits the range of samples that can be studied. We have developed a new method that combines the ptychographic approach in one direction with Fresnel propagation in the other by employing a strongly asymmetric probe. This enables scanning the sample in one direction only, substantially reducing exposure times while covering a large field of view. This approach sacrifices ptychographic-related resolution in one direction, but removes any limitation on the probe dimension in the direction orthogonal to the scanning, enabling the scan of relatively large objects without compromising exposure times.

7.
Opt Lett ; 39(11): 3332-5, 2014 Jun 01.
Article in English | MEDLINE | ID: mdl-24876046

ABSTRACT

We report on the design and realization of an x-ray imaging system for quantitative phase-contrast microscopy at high x-ray energy with laboratory-scale instrumentation. Phase and amplitude were separated quantitatively at x-ray energies up to 80 keV with micrometric spatial resolution. The accuracy of the results was tested against numerical simulations, and the spatial resolution was experimentally quantified by measuring a Siemens star phase object. This simple setup should find broad application in those areas of x-ray imaging where high energy and spatial resolution are simultaneously required and in those difficult cases where the sample contains materials with similar x-ray absorption.


Subject(s)
Microscopy, Phase-Contrast/instrumentation , Equipment Design , Microscopy, Phase-Contrast/methods , Optical Phenomena , X-Rays
SELECTION OF CITATIONS
SEARCH DETAIL
...