Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
1.
Circ Cardiovasc Qual Outcomes ; 9(5): 593-9, 2016 09.
Article in English | MEDLINE | ID: mdl-27553597

ABSTRACT

Postoperative atrial fibrillation (POAF) is a frequent complication of cardiac surgery, which results in increased morbidity, mortality, length of stay, and hospital costs. We developed and followed a process map to implement a protocol to decrease POAF: (1) identify stakeholders and form a working committee, (2) formal literature and guideline review, (3) retrospective analysis of current institutional data, (4) data modeling to determine expected effects of change, (4) protocol development and implementation into the electronic medical record, and (5) ongoing review of data and protocol adjustment. Retrospective analysis demonstrated that POAF occurred in 29.8% of all cardiovascular surgery cases. Median length of stay was 2 days longer (P<0.001), and median total variable costs $2495 higher (P<0.001) in POAF patients. Modeling predicted that up to 60 cases of POAF and >$200 000 annually could be saved. A clinically based electronic medical record tool was implemented into the electronic medical record to aid preoperative clinic providers in identifying patients eligible for prophylactic amiodarone. Initial results during the 9-month period after implementation demonstrated a reduction in POAF in patients using the protocol, compared with those who qualified but did not receive amiodarone and those not evaluated (11.1% versus 38.7% and 38.8%; P=0.022); however, only 17.3% of patients used the protocol. A standardized methodological approach to quality improvement and electronic medical record integration has potential to significantly decrease the incidence of POAF, length of stay, and total variable cost in patients undergoing elective coronary artery bypass graft and valve surgeries. This framework for quality improvement interventions may be adapted to similar clinical problems beyond POAF.


Subject(s)
Amiodarone/administration & dosage , Anti-Arrhythmia Agents/administration & dosage , Atrial Fibrillation/prevention & control , Cardiac Surgical Procedures/adverse effects , Clinical Protocols , Data Mining/methods , Electronic Health Records , Health Services Research/methods , Heart Valves/surgery , Quality Improvement , Quality Indicators, Health Care , Amiodarone/adverse effects , Amiodarone/economics , Anti-Arrhythmia Agents/adverse effects , Anti-Arrhythmia Agents/economics , Atrial Fibrillation/economics , Atrial Fibrillation/etiology , Atrial Fibrillation/mortality , Cardiac Surgical Procedures/economics , Cardiac Surgical Procedures/mortality , Coronary Artery Bypass/adverse effects , Cost Savings , Cost-Benefit Analysis , Drug Costs , Hospital Costs , Humans , Incidence , Length of Stay , Models, Economic , Retrospective Studies , Risk Factors , Time Factors , Treatment Outcome , United States/epidemiology
2.
J Thorac Cardiovasc Surg ; 131(6): 1261-6, 2006 Jun.
Article in English | MEDLINE | ID: mdl-16733155

ABSTRACT

OBJECTIVE: Coronary artery bypass graft surgery carries increased risk for patients requiring dialysis compared with other groups. Little data exist comparing outcomes of on-pump and off-pump techniques in dialysis patients. This study compares outcomes of bypass grafting in dialysis patients with these two techniques at a single institution and in the United States Renal Data System (USRDS) database. METHODS: From March 1997 to April 2004, 37 patients requiring dialysis underwent bypass graft surgery at our institution. On-pump surgery was performed for 16 patients and off-pump surgery for 21. From January 1, 2001, to December 31, 2002, a total of 3922 patients in the USRDS underwent bypass graft surgery. On-pump surgery was performed for 3382 and off-pump surgery for 540. Comparisons were made between patients undergoing on-pump and off-pump bypass surgery with respect to demographics, risk factors, and outcomes. Univariate analysis, the Kaplan-Meier method, and a multivariate Cox model were used. RESULTS: Institutional analysis revealed similar patient demographics, risk factors, use of thoracic artery grafts, and number of distal anastomoses. Outcome analysis was significant for less postoperative atrial fibrillation with the off-pump technique: 37.5% on-pump and 4.8% off-pump (P = .028). USRDS data revealed all-cause survivals at 1 and 18 months of 87.5% and 59.5% for on-pump versus 88.3% and 61.9% for off-pump procedures (P = .226). In a comorbidity-adjusted Cox model, off-pump bypass grafting was associated with a 16% reduction in all-cause mortality (P = .032). CONCLUSION: Off-pump bypass grafting is uncommon in patients in the United States who require dialysis. Off- pump bypass grafting provides a morbidity benefit and is associated with a lower risk of death.


Subject(s)
Coronary Artery Bypass , Coronary Disease/surgery , Kidney Failure, Chronic/therapy , Renal Dialysis , Coronary Artery Bypass, Off-Pump , Coronary Disease/complications , Female , Humans , Kidney Failure, Chronic/complications , Male , Middle Aged , Retrospective Studies , Treatment Outcome , United States
SELECTION OF CITATIONS
SEARCH DETAIL
...