Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Language
Publication year range
1.
BMC Oral Health ; 24(1): 513, 2024 May 02.
Article in English | MEDLINE | ID: mdl-38698366

ABSTRACT

BACKGROUND: This study aims to evaluate the effect of surface treatment and resin cement on the shear bond strength (SBS) and mode of failure of polyetheretherketone (PEEK) to lithium disilicate ceramic (LDC). This is suggested to study alternative veneering of PEEK frameworks with a ceramic material. METHODS: eighty discs were prepared from PEEK blank and from lithium disilicate ceramic. Samples were divided into four groups according to surface treatment: Group (A) air abraded with 110 µm Al2O3, Group (AP) air abrasion and primer application, Group (S) 98% sulfuric acid etching for 60 s, Group (SP) Sulfuric acid and primer. Each group was subdivided into two subgroups based on resin cement type used for bonding LDC:1) subgroup (L) self- adhesive resin cement and 2) subgroup (B) conventional resin cement (n = 10). Thermocycling was done for all samples. The bond strength was assessed using the shear bond strength test (SBS). Failure mode analysis was done at 50X magnification with a stereomicroscope. Samples were chosen from each group for scanning electron microscope (SEM). The three-way nested ANOVA followed by Tukey's post hoc test were used for statistical analysis of results. Comparisons of effects were done utilizing one way ANOVA and (p < 0.05). RESULTS: The highest mean of shear bond strength values was demonstrated in Group of air abrasion with primer application using conventional resin cement (APB) (12.21 ± 2.14 MPa). Sulfuric acid groups showed lower shear bond strength values and the majority failed in thermocycling especially when no primer was applied. The failure mode analysis showed that the predominant failure type was adhesive failure between cement and PEEK, while the remaining was mixed failure between cement and PEEK. CONCLUSION: The air abrasion followed by primer application and conventional resin cement used for bonding Lithium Disilicate to PEEK achieved the best bond strength. Primer application did not have an effect when self-adhesive resin cement was used in air-abraded groups. Priming step is mandatory whenever sulfuric acid etching surface treatment is utilized for PEEK.


Subject(s)
Benzophenones , Dental Bonding , Dental Porcelain , Dental Stress Analysis , Ketones , Materials Testing , Polyethylene Glycols , Polymers , Resin Cements , Shear Strength , Surface Properties , Dental Bonding/methods , Acid Etching, Dental/methods , Sulfuric Acids , Ceramics/chemistry , Air Abrasion, Dental/methods , Aluminum Oxide , Dental Veneers , Dental Etching/methods , Humans
2.
BMC Oral Health ; 23(1): 17, 2023 01 12.
Article in English | MEDLINE | ID: mdl-36635647

ABSTRACT

OBJECTIVES: Evaluating the bond strength of two ceramic materials to dentin after Er,Cr:YSGG laser debonding. Would laser debonding affect the bond strength of ceramic to dentin? MATERIALS AND METHODS: Recently extracted human molars were ground to expose dentin. Forty square shaped samples were prepared from CAD/CAM ceramic blocks. Samples were divided into two groups according to the type of ceramic material; group E: Lithium disilicate and group T: Ultra-translucent Zirconia (n = 20) Each group was divided into two subgroups (n = 10) according to the laser debonding effect (subgroup B: bonded samples, subgroup R: re-bonded samples after laser debonding). Ceramic samples were bonded to dentin using dual cure self-adhesive resin cement. Laser debonding of ceramic samples of subgroups R using Er, Cr:YSGG laser, were then re-bonded again to dentin surface with same resin cement. The Shear bond strength test using Universal testing machine was done. The failure mode was analyzed. Two-way analysis of variance was used to compare the mean bond strength and re-bond strength of two materials. The significance level was set at P ≤ 0.05. RESULTS: Two-Way ANOVA showed that ceramic type had a significant effect on the re-bond strength to dentin. The predominant failure mode was adhesive. CONCLUSIONS: Laser debonding of Lithium disilicate and Ultra translucent Zirconia decreased the re-bond strength to dentin. Deterioration in re-bond strength for Lithium disilicate ceramics was more pronounced than for Ultra translucent Zirconia. Clinical Relevance Deterioration in the bond strength between ceramics & dentin after laser debonding still needs improvement to allow its clinical use.


Subject(s)
Dental Bonding , Lasers, Solid-State , Humans , Lasers, Solid-State/therapeutic use , Resin Cements/chemistry , Ceramics/chemistry , Dentin , Materials Testing , Shear Strength , Surface Properties
3.
Braz. dent. sci ; 23(4): 1-9, 2020. tab, ilus
Article in English | BBO - Dentistry , LILACS | ID: biblio-1121845

ABSTRACT

Objective: The purpose of this in vitro study was to evaluate the marginal fit of laminate veneers made of zirconia-reinforced lithium silicate with two thicknesses using different CAD/CAM systems. Material and methods: 42 Laminate veneers milled from zirconia-reinforced lithium silicate were divided into three main groups according to milling machine used into: group X5, laminate veneers fabricated by inLab MCX5 milling machine; group CM, laminate veneers fabricated by Ceramill motion 2 milling machine; and group XL, laminate veneers fabricated by inLab MCXL milling machine. Each group was divided into two subgroups according to veneer thickness into: subgroup I, 0.5 mm thickness laminate veneers and subgroup II, 0.3 mm thickness laminate veneers. The marginal fit was measured using stereomicroscope. The results were tabulated and statistically analyzed using two-way ANOVA test followed by Tukey's post hoc test. Comparisons of main and simple effects were done utilizing Bonferroni correction. The significance level was set at (p ≤0.05) for all tests. Results: The mean( ± SD) highest marginal discrepancy was recorded in subgroup CMII at 85.45 ± 1.82 µm while the least mean marginal discrepancy was recorded in subgroup X5I (71.24 ± 2.64 µm). Conclusion: Both thicknesses(0.5 mm thickness and 0.3 mm thickness) and all tested CAD/CAM systems produced zirconia-reinforced lithium silicate laminate veneers with clinically acceptable marginal gaps; however, the closed CAD/CAM systems produced veneers with superior marginal fit than open systems at 0.3 mm thickness. The CAD/CAM system with the 5-axis milling machine produced the best marginal fit with 0.5 mm thickness. (AU)


Objetivo: O objetivo deste estudo in vitro foi avaliar a adaptação marginal de facetas laminadas de silicato de lítio reforçado com zircônia com duas espessuras, utilizando diferentes sistemas CAD / CAM. Material e métodos: 42 facetas laminadas fresadas a partir desilicato de lítio reforçado com zircônia foram divididos em três grupos principais de acordo com a fresadora usada em: grupo X5, facetas laminadas fabricados pela fresadora inLab MCX5; grupo CM, facetas laminadas fabricados por Ceramill motion 2; e grupo XL, facetas laminadas fabricados pelo inLab MCXL. Cada grupo foi dividido em dois subgrupos, de acordo com a espessura do laminado, em: subgrupo I, facetas laminadas com 0,5 mm de espessura e subgrupo II, facetas laminadas com espessura de 0,3 mm. A adaptação marginal foi medida usando estereomicroscópio. Os resultados foram tabulados e analisados estatisticamente usando o teste ANOVA de dois fatores seguido pelo teste post hoc de Tukey. Comparações dos efeitos principais e simples foram realizadas utilizando a correção de Bonferroni (P ≤ 0,05). Resultados: A maior discrepância marginal média ( ± DP) foi registrada no subgrupo CMII em 85,45 ± 1,82 µm, enquanto a menor discrepância marginal média foi registrada no subgrupo X5I 71,24 ± 2,64 µm. Conclusão: Ambas as espessuras (0,5 mm e 0,3 mm)e todos os sistemas CAD / CAM testados produziram facetas de laminado de silicato de lítio reforçadas com zircônia com lacunas clinicamente aceitáveis. No entanto, os sistemas CAD / CAM fechados produziam facetas com adaptação marginal superior aos sistemas abertos com 0,3 mm de espessura. O sistema CAD / CAM com a fresadora de 5 eixos produziu a melhor adaptação marginal com 0,5 mm de espessura (AU)


Subject(s)
Computer-Aided Design , Dental Marginal Adaptation , Dental Veneers
SELECTION OF CITATIONS
SEARCH DETAIL
...