Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
J Cardiothorac Surg ; 15(1): 23, 2020 Jan 17.
Article in English | MEDLINE | ID: mdl-31952527

ABSTRACT

BACKGROUND: Accumulating evidence consistently demonstrates that blood transfusion in cardiac surgery is related to decreased short- and long-term survival. We aimed to evaluate periprocedural blood loss and transfusion rates in elective, isolated total arterial coronary artery bypass grafting (CABG) using exclusively skeletonized bilateral internal mammary arteries (IMAs). METHODS: We identified 1011 consecutive patients with coronary artery disease who underwent CABG between 1/2007 and 12/2014. Of them, 595 patients who presented preoperative hemoglobin levels >9md/dl and underwent elective, isolated CABG for multi-vessel coronary artery disease were included in the study population. 419 patients (70.4%) received total arterial CABG using skeletonized bilateral IMAs, in 176 patients (29.6%) mixed CABG (single IMA & saphenous vein) was performed. Propensity score adjustment using 16 variables was applied to control for treatment effect. RESULTS: In patients undergoing total arterial CABG, heterologous blood transfusion could be avoided in 87.8% of all cases. Propensity score adjusted results showed a significantly lower incidence of erythrocyte concentrate transfusion in patients undergoing total arterial CABG compared to mixed CABG (odds ratio 2.74, 95% confidence interval 1.38-5.43, P = 0.004). There were no statistically significant differences in the rates of thrombocyte concentrate (P = 0.39) and fresh frozen plasma transfusions (P = 0.07). CONCLUSIONS: In this study, patients who underwent elective, isolated total arterial CABG using exclusively skeletonized bilateral IMAs showed reduced transfusion rates of erythrocyte concentrates compared to mixed CABG using a combination of single IMA and saphenous vein grafts. No evidence for a higher incidence of complications was found with a total arterial approach.


Subject(s)
Blood Transfusion , Coronary Artery Bypass/adverse effects , Coronary Artery Disease/surgery , Mammary Arteries/transplantation , Aged , Aged, 80 and over , Blood Loss, Surgical , Coronary Artery Bypass/methods , Female , Humans , Male , Middle Aged , Odds Ratio , Postoperative Hemorrhage/therapy , Propensity Score , Saphenous Vein/transplantation , Treatment Outcome
2.
Thorac Cardiovasc Surg ; 66(3): 261-265, 2018 04.
Article in English | MEDLINE | ID: mdl-28380656

ABSTRACT

BACKGROUND: The purpose of this single-center, retrospective study was to review the early outcome with defined endpoints of myocardial infarction, brain injury, and death after coronary bypass grafting and simultaneous carotid endarterectomy with or without combined valve replacement. METHODS: During the preoperative investigation 52 (44 males, 8 females) patients were examined by cardiac catheterization within the scope of their coronary status. In addition, all patients underwent echocardiography, CT angiography of the supra-aortic vessels, and full description of their neurologic status. Included were all patients with the need of coronary revascularization, valve disease, and either symptomatic or asymptomatic carotid artery stenosis with a maximal narrowing of >70%. RESULTS: There was one (2%) patient with a perioperative stroke and paresis of the upper limb. One (2%) patient experienced PRIND (2%). Eighteen (35%) patients suffered symptomatic transitory psychotic syndrome that fully recovered in all patients. One (2%) patient incurred a perioperative myocardial infarction that could be cured by percutaneous coronary stent implantation. Overall mortality was 4%. CONCLUSION: Simultaneous coronary bypass grafting as a single procedure or in combination with valve replacement and endarterectomy of severe carotid lesions with or without patients' history of previous stroke can be performed with a calculated low surgical risk. The complication rate for neurologic and myocardial events is low compared with the hazard of a single surgical repair. The in-hospital mortality is not significantly different to isolated procedures. The concomitant appearance of coronary stenosis and carotid artery disease is reasonable due to the nature of arteriosclerosis. In our opinion these patients benefit from a combined surgical approach.


Subject(s)
Carotid Stenosis/surgery , Coronary Artery Bypass , Coronary Artery Disease/surgery , Endarterectomy, Carotid , Heart Valve Diseases/surgery , Heart Valve Prosthesis Implantation , Aged , Carotid Stenosis/complications , Carotid Stenosis/diagnostic imaging , Carotid Stenosis/mortality , Computed Tomography Angiography , Coronary Artery Bypass/adverse effects , Coronary Artery Bypass/mortality , Coronary Artery Disease/complications , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/mortality , Echocardiography , Endarterectomy, Carotid/adverse effects , Endarterectomy, Carotid/mortality , Female , Germany , Heart Valve Diseases/complications , Heart Valve Diseases/diagnostic imaging , Heart Valve Diseases/mortality , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/mortality , Humans , Male , Middle Aged , Myocardial Infarction/etiology , Paresis/etiology , Retrospective Studies , Risk Factors , Stroke/etiology , Time Factors , Treatment Outcome
3.
J Cardiovasc Med (Hagerstown) ; 13(10): 651-2, 2012 Oct.
Article in English | MEDLINE | ID: mdl-22929569

ABSTRACT

Pacemaker lead infections are rare but potentially life threatening. We report the case of an 80-year-old pacemaker-dependent female patient with complete heart block, who presented with subfebrile temperatures and chills due to a pacemaker lead infection by Enterococcus faecalis.


Subject(s)
Enterococcus faecalis/isolation & purification , Gram-Positive Bacterial Infections/microbiology , Pacemaker, Artificial/adverse effects , Aged, 80 and over , Anti-Bacterial Agents/therapeutic use , Chills/microbiology , Device Removal , Echocardiography, Transesophageal , Equipment Design , Female , Gram-Positive Bacterial Infections/diagnosis , Gram-Positive Bacterial Infections/therapy , Humans , Treatment Outcome
4.
Pacing Clin Electrophysiol ; 28(9): 926-32, 2005 Sep.
Article in English | MEDLINE | ID: mdl-16176531

ABSTRACT

BACKGROUND: Although more than 150,000 implantable cardioverter defibrillators (ICDs) are implanted yearly worldwide, only few studies systematically examined complications of ICD therapy in large patient cohorts. METHODS: We prospectively analyzed ICD-related complications in 440 consecutive patients who underwent first implantation of an ICD system for primary or secondary prevention of sudden cardiac death within the last 10 years at our institution. All study patients received pectoral nonthoracotomy ICD lead systems with the exception of one patient who had an artificial tricuspid valve. RESULTS: During 46 +/- 37 months follow-up, 136 of 440 patients (31%) experienced at least one complication including implant procedure-related complications in 43 patients (10%), ICD generator-related complications in 28 patients (6%), lead-related complications in 52 patients (12%), and inappropriate shocks in 54 patients (12%). The most serious complications included one perioperative death due to heart failure (0.2%), two ICD system infections necessitating device removal (0.5%) and two perioperative cerebrovascular strokes (0.5%). CONCLUSIONS: We conclude that more than one quarter of ICD patients experience complications during a mean follow-up of almost 4 years, although serious complications such as intraoperative death or ICD system infections are rare in patients with nonthoracotomy ICD systems. Recognition of these complications is the prerequisite for advances in ICD technology and management strategies to avoid their recurrence.


Subject(s)
Death, Sudden, Cardiac/prevention & control , Defibrillators, Implantable , Postoperative Complications/epidemiology , Female , Humans , Incidence , Male , Middle Aged , Prospective Studies , Risk Assessment
5.
Pacing Clin Electrophysiol ; 28 Suppl 1: S5-7, 2005 Jan.
Article in English | MEDLINE | ID: mdl-15683524

ABSTRACT

We monitored reverse left ventricular (LV) remodeling and LV function during the first 6 months of cardiac resynchronization therapy (CRT) in 34 patients (mean age = 55.3 +/- 13.6 years, 28 men) with dilated cardiomyopathy (DCM), left bundle branch block, in stable New York Heart Association class III, and on fixed drug regimen who underwent implantation of CRT systems with or without cardioverter defibrillator back-up. QRS-complex duration was reduced from 169.69 +/- 19.6 ms (SD) to 144.1 +/- 23.4 ms during CRT. Parasternal M-mode and apical 2D-echocardiography was performed before and 3 and 6 months after device implantation. LV enddiastolic (EDD) and endsystolic (ESD) diameters were measured, and biplane LV enddiastolic (EDV), and endsystolic (ESV) volumes and ejection fractions (EF) were calculated using a modified Simpson formula. Significant decreases in LVEDD (P = 0.0064 at 3 months and P = 0.021 at 6 months), LVESD (P = 0.023 at 3 months, and P = 0.003 at 6 months), and LVESV (P = 0.006 resp. P = 0.007), and increases in LVEF (P = 0.003 at 3 months and P < 0.001 at 6 months) were observed. Mean LVEF increased from 23% at baseline to 39% at 6 months. CRT induced prominent reverse LV remodeling and significantly increased LVEF within a few months in patients with DCM.


Subject(s)
Cardiac Pacing, Artificial , Cardiomyopathy, Dilated/therapy , Stroke Volume , Ventricular Function, Left , Ventricular Remodeling , Cardiomyopathy, Dilated/physiopathology , Female , Humans , Male , Middle Aged , Time Factors
SELECTION OF CITATIONS
SEARCH DETAIL
...