Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Rev Sci Instrum ; 90(11): 115101, 2019 Nov 01.
Article in English | MEDLINE | ID: mdl-31779457

ABSTRACT

This paper describes the design and operation of the Polaris time-of-flight powder neutron diffractometer at the ISIS pulsed spallation neutron source, Rutherford Appleton Laboratory, UK. Following a major upgrade to the diffractometer in 2010-2011, its detector provision now comprises five large ZnS scintillator-based banks, covering an angular range of 6° ≤ 2θ ≤ 168°, with only minimal gaps between each bank. These detectors have a substantially increased solid angle coverage (Ω âˆ¼ 5.67 sr) compared to the previous instrument (Ω âˆ¼ 0.82 sr), resulting in increases in count rate of between 2× and 10×, depending on 2θ angle. The benefits arising from the high count rates achieved are illustrated using selected examples of experiments studying small sample volumes and performing rapid, time-resolved investigations. In addition, the enhanced capabilities of the diffractometer in the areas of in situ studies (which are facilitated by the installation of a novel design of radial collimator around the sample position and by a complementary programme of advanced sample environment developments) and in total scattering studies (to probe the nature of short-range atomic correlations within disordered crystalline solids) are demonstrated.

2.
Rev Sci Instrum ; 90(3): 035110, 2019 Mar.
Article in English | MEDLINE | ID: mdl-30927771

ABSTRACT

The MAPS direct geometry time-of-flight chopper spectrometer at the ISIS pulsed neutron and muon source has been in operation since 1999, and its novel use of a large array of position-sensitive neutron detectors paved the way for a later generations of chopper spectrometers around the world. Almost two decades of experience of user operations on MAPS, together with lessons learned from the operation of new generation instruments, led to a decision to perform three parallel upgrades to the instrument. These were to replace the primary beamline collimation with supermirror neutron guides, to install a disk chopper, and to modify the geometry of the poisoning in the water moderator viewed by MAPS. Together, these upgrades were expected to increase the neutron flux substantially, to allow more flexible use of repetition rate multiplication and to reduce some sources of background. Here, we report the details of these upgrades and compare the performance of the instrument before and after their installation as well as to Monte Carlo simulations. These illustrate that the instrument is performing in line with, and in some respects in excess of, expectations. It is anticipated that the improvement in performance will have a significant impact on the capabilities of the instrument. A few examples of scientific commissioning are presented to illustrate some of the possibilities.

3.
Rev Sci Instrum ; 87(12): 125111, 2016 Dec.
Article in English | MEDLINE | ID: mdl-28040964

ABSTRACT

A high power pulsed laser system has been installed on the high magnetic field muon spectrometer (HiFi) at the International Science Information Service pulsed neutron and muon source, situated at the STFC Rutherford Appleton Laboratory in the UK. The upgrade enables one to perform light-pump muon-probe experiments under a high magnetic field, which opens new applications of muon spin spectroscopy. In this report we give an overview of the principle of the HiFi laser system and describe the newly developed techniques and devices that enable precisely controlled photoexcitation of samples in the muon instrument. A demonstration experiment illustrates the potential of this unique combination of the photoexcited system and avoided level crossing technique.

SELECTION OF CITATIONS
SEARCH DETAIL
...