Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters










Database
Language
Publication year range
1.
J Vasc Surg ; 54(2): 316-24; discussion 324-5, 2011 Aug.
Article in English | MEDLINE | ID: mdl-21819922

ABSTRACT

OBJECTIVE: Structural changes within the aorta after thoracic endovascular aortic repair (TEVAR) for acute complicated type B thoracic aortic dissections (ABAD) remain unknown. This study reviewed and analyzed morphologic changes, volumetric data, and clinical outcomes of patients with ABAD. METHODS: Forty-one consecutive patients with ABAD, all with the volumetric analysis of aortic luminal changes and ≥1 year of follow-up, were treated as a part of a single-center U.S. Food and Drug Administration (FDA)-approved investigational device exemption (IDE) trial from 2002 to 2009. Indications were malperfusion in 17, rupture in 12, chest pain in 6, acute enlargement in 4, and uncontrolled hypertension in 2. Duration of symptoms was ≤14 days. Three-dimensional M2S computed tomography reconstructions (Medical MetRx Solutions, West Lebanon, NH) were analyzed for aortic volume and diameter changes, regression of the false lumen, and expansion of the true lumen. RESULTS: Emergent surgery was required in 17 (42%) patients, excluding one death at induction. Procedural success rate was 92.5%. The 30-day mortality was 4.9% for malperfusion, 4.9% for rupture, and 0% for all others, with late mortality of 0%, 9.8%, and 7.3%, respectively. Mean follow-up was 12.4 months. Permanent stroke and paraplegia rates were 4.9% (n = 2) and 0%. Ten of 12 secondary interventions were performed for 6 proximal endoleaks, 1 distal cuff endoleak, and 3 distal reperfusions. For the 33 patients without endoleaks, the true lumen volume increased by 29% at 1 month, 51% at 1 year, and 80% at 5 years. Volume regression of the false lumen was 69%, 76%, and 86%, respectively. The true lumen volume did not change at 1 month or 1 year in the endoleak group (n = 7) but increased 50% at 2 years after secondary intervention. A 10% reduction of abdominal aortic volume distal to endograft occurred over 5 years in the absence of endoleaks. CONCLUSIONS: TEVAR offers a promising solution to patients with ABAD. Aortic morphologic changes occur shortly after TEVAR and remain predictable up to 5 years with continuous expansion of the true lumen and regression of the false lumen. A lack of increase in the true lumen volume is associated with endoleaks or distal reperfusion.


Subject(s)
Aortic Aneurysm, Thoracic/surgery , Aortic Dissection/surgery , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Acute Disease , Adult , Aged , Aged, 80 and over , Aortic Dissection/complications , Aortic Dissection/diagnostic imaging , Aortic Dissection/mortality , Aortic Aneurysm, Thoracic/complications , Aortic Aneurysm, Thoracic/diagnostic imaging , Aortic Aneurysm, Thoracic/mortality , Aortic Rupture/etiology , Aortic Rupture/surgery , Aortography/methods , Blood Vessel Prosthesis , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis Implantation/mortality , California , Chest Pain/etiology , Endoleak/etiology , Endovascular Procedures/adverse effects , Endovascular Procedures/instrumentation , Endovascular Procedures/mortality , Female , Humans , Hypertension/etiology , Imaging, Three-Dimensional , Male , Middle Aged , Paraplegia/etiology , Prospective Studies , Prosthesis Design , Radiographic Image Interpretation, Computer-Assisted , Stents , Stroke/etiology , Time Factors , Tomography, X-Ray Computed , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...