Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 47
Filter
1.
Eur Heart J Qual Care Clin Outcomes ; 9(2): 150-160, 2023 02 28.
Article in English | MEDLINE | ID: mdl-35700131

ABSTRACT

AIMS: Population studies reporting contemporary long-term outcomes following catheter ablation of atrial fibrillation (AF) are sparse.We evaluated long-term clinical outcomes following AF ablation and examined variation in outcomes by age, sex, and the presence of heart failure. METHODS AND RESULTS: We identified 30 601 unique patients (mean age 62.7 ± 11.8 years, 30.0% female) undergoing AF ablation from 2008 to 2017 in Australia and New Zealand using nationwide hospitalization data. The primary outcomes were all-cause mortality and rehospitalizations for AF or flutter, repeat AF ablation, and cardioversion. Secondary outcomes were rehospitalizations for other cardiovascular events. During 124 858.7 person-years of follow-up, 1900 patients died (incidence rate 1.5/100 person-years) with a survival probability of 93.0% (95% confidence interval (CI) 92.6-93.4%) by 5 years and 84.0% (95% CI 82.4-85.5%) by 10 years. Rehospitalizations for AF or flutter (13.3/100 person-years), repeat ablation (5.9/100 person-years), and cardioversion (4.5/100 person-years) were common, with respective cumulative incidence of 49.4% (95% CI 48.4-50.4%), 28.1% (95% CI 27.2-29.0%), and 24.4% (95% CI 21.5-27.5%) at 10 years post-ablation. Rehospitalizations for stroke (0.7/100 person-years), heart failure (1.1/100 person-years), acute myocardial infarction (0.4/100 person-years), syncope (0.6/100 person-years), other arrhythmias (2.5/100 person-years), and new cardiac device implantation (2.0/100 person-years) occurred less frequently. Elderly patients and those with comorbid heart failure had worse survival but were less likely to undergo repeat ablation, while long-term outcomes were comparable between the sexes. CONCLUSION: Patients undergoing AF ablations had good long-term survival, a low incidence of rehospitalizations for stroke or heart failure, and about half remained free of rehospitalizations for AF or flutter, including for repeat AF ablation, or cardioversion.


Subject(s)
Atrial Fibrillation , Atrial Flutter , Catheter Ablation , Heart Failure , Stroke , Humans , Female , Aged , Middle Aged , Male , Cohort Studies , Atrial Fibrillation/epidemiology , Atrial Fibrillation/surgery , Atrial Flutter/epidemiology , Atrial Flutter/surgery , Atrial Flutter/complications , Stroke/epidemiology , Hospitalization , Catheter Ablation/adverse effects , Catheter Ablation/methods , Heart Failure/complications
2.
Cardiol Rev ; 2022 Nov 21.
Article in English | MEDLINE | ID: mdl-36730485

ABSTRACT

Atrial fibrillation (AF) is a prevalent problem worldwide and a common cause of hospitalization, poor quality of life, and increased mortality. Although several treatments are used, the use of ablation and antiarrhythmic drug therapy has increased in the past decade. However, debate continues on the most suitable option for heart rhythm control in patients. Previous studies have largely focused on short-term outcome effects of these treatments. This systematic review aims to determine the effect of ablation compared to antiarrhythmic drugs for AF on long-term patient and health service outcomes of mortality, hospitalization, and quality of life. Three databases were systematically searched-studies were included if they reported long-term outcomes of more than 12 months comparing the 2 treatments. Title and abstract screening and subsequent full-text screening was done by 2 reviewers. Data were extracted from the final studies identified. The details of the search were recorded according to Preferred Reporting Items for Systematic Reviews and Meta-Analyses report. A total of 2224 records were identified. After removing duplicates and screening the titles and abstracts, 68 records required full-text screening. Finally, 12 papers were included in the analysis. Eight studies reported mortality indicating ablation was superior, 2 studies reported hospitalization with opposing outcomes, and 5 quality of life studies indicating ablation was a better treatment. In studies assessing long-term outcomes, beyond 12 months, following ablation or rhythm control drugs for AF, most found a lower risk of death and greater improvement in quality of life in the ablation group.

3.
JAMA Cardiol ; 6(11): 1285-1295, 2021 11 01.
Article in English | MEDLINE | ID: mdl-34347007

ABSTRACT

Importance: Millions of clinicians rely daily on automated preliminary electrocardiogram (ECG) interpretation. Critical comparisons of machine learning-based automated analysis against clinically accepted standards of care are lacking. Objective: To use readily available 12-lead ECG data to train and apply an explainability technique to a convolutional neural network (CNN) that achieves high performance against clinical standards of care. Design, Setting, and Participants: This cross-sectional study was conducted using data from January 1, 2003, to December 31, 2018. Data were obtained in a commonly available 12-lead ECG format from a single-center tertiary care institution. All patients aged 18 years or older who received ECGs at the University of California, San Francisco, were included, yielding a total of 365 009 patients. Data were analyzed from January 1, 2019, to March 2, 2021. Exposures: A CNN was trained to predict the presence of 38 diagnostic classes in 5 categories from 12-lead ECG data. A CNN explainability technique called LIME (Linear Interpretable Model-Agnostic Explanations) was used to visualize ECG segments contributing to CNN diagnoses. Main Outcomes and Measures: Area under the receiver operating characteristic curve (AUC), sensitivity, and specificity were calculated for the CNN in the holdout test data set against cardiologist clinical diagnoses. For a second validation, 3 electrophysiologists provided consensus committee diagnoses against which the CNN, cardiologist clinical diagnosis, and MUSE (GE Healthcare) automated analysis performance was compared using the F1 score; AUC, sensitivity, and specificity were also calculated for the CNN against the consensus committee. Results: A total of 992 748 ECGs from 365 009 adult patients (mean [SD] age, 56.2 [17.6] years; 183 600 women [50.3%]; and 175 277 White patients [48.0%]) were included in the analysis. In 91 440 test data set ECGs, the CNN demonstrated an AUC of at least 0.960 for 32 of 38 classes (84.2%). Against the consensus committee diagnoses, the CNN had higher frequency-weighted mean F1 scores than both cardiologists and MUSE in all 5 categories (CNN frequency-weighted F1 score for rhythm, 0.812; conduction, 0.729; chamber diagnosis, 0.598; infarct, 0.674; and other diagnosis, 0.875). For 32 of 38 classes (84.2%), the CNN had AUCs of at least 0.910 and demonstrated comparable F1 scores and higher sensitivity than cardiologists, except for atrial fibrillation (CNN F1 score, 0.847 vs cardiologist F1 score, 0.881), junctional rhythm (0.526 vs 0.727), premature ventricular complex (0.786 vs 0.800), and Wolff-Parkinson-White (0.800 vs 0.842). Compared with MUSE, the CNN had higher F1 scores for all classes except supraventricular tachycardia (CNN F1 score, 0.696 vs MUSE F1 score, 0.714). The LIME technique highlighted physiologically relevant ECG segments. Conclusions and Relevance: The results of this cross-sectional study suggest that readily available ECG data can be used to train a CNN algorithm to achieve comparable performance to clinical cardiologists and exceed the performance of MUSE automated analysis for most diagnoses, with some exceptions. The LIME explainability technique applied to CNNs highlights physiologically relevant ECG segments that contribute to the CNN's diagnoses.


Subject(s)
Algorithms , Cardiovascular Diseases/diagnosis , Consensus , Electrocardiography/methods , Heart Rate/physiology , Machine Learning , Neural Networks, Computer , Cardiovascular Diseases/physiopathology , Cross-Sectional Studies , Female , Follow-Up Studies , Humans , Male , Middle Aged , ROC Curve , Retrospective Studies
4.
J Am Heart Assoc ; 10(13): e019212, 2021 07 06.
Article in English | MEDLINE | ID: mdl-34169736

ABSTRACT

Background Leadless pacemaker is a novel technology, and evidence supporting its use is uncertain. We performed a systematic review and meta-analysis to examine the safety and efficacy of leadless pacemakers implanted in the right ventricle. Methods and Results We searched PubMed and Embase for studies published before June 6, 2020. The primary safety outcome was major complications, whereas the primary efficacy end point was acceptable pacing capture threshold (≤2 V). Pooled estimates were calculated using the Freedman-Tukey double arcsine transformation. Of 1281 records screened, we identified 36 observational studies of Nanostim and Micra leadless pacemakers, with most (69.4%) reporting outcomes for the Micra. For Micra, the pooled incidence of complications at 90 days (n=1608) was 0.46% (95% CI, 0.08%-1.05%) and at 1 year (n=3194) was 1.77% (95% CI, 0.76%-3.07%). In 5 studies with up to 1-year follow-up, Micra was associated with 51% lower odds of complications compared with transvenous pacemakers (3.30% versus 7.43%; odds ratio [OR], 0.49; 95% CI, 0.34-0.70). At 1 year, 98.96% (95% CI, 97.26%-99.94%) of 1376 patients implanted with Micra had good pacing capture thresholds. For Nanostim, the reported complication incidence ranged from 6.06% to 23.54% at 90 days and 5.33% to 6.67% at 1 year, with 90% to 100% having good pacing capture thresholds at 1 year (pooled result not estimated because of the low number of studies). Conclusions Most studies report outcomes for the Micra, which is associated with a low risk of complications and good electrical performance up to 1-year after implantation. Further data from randomized controlled trials are needed to support the widespread adoption of these devices in clinical practice.


Subject(s)
Arrhythmias, Cardiac/therapy , Cardiac Pacing, Artificial/methods , Pacemaker, Artificial , Arrhythmias, Cardiac/physiopathology , Equipment Design , Heart Ventricles , Humans , Treatment Outcome
5.
JACC Clin Electrophysiol ; 7(7): 858-870, 2021 07.
Article in English | MEDLINE | ID: mdl-33640350

ABSTRACT

OBJECTIVES: This study describes a series of cases best explained by invoking the left septal fascicle (LSF) as a critical component of the arrhythmia circuit. BACKGROUND: Numerous anatomic studies have shown evidence of the LSF, but its precise role in the onset of arrhythmia is unclear. METHODS: This paper presents 5 cases that implicated the LSF as a critical component of arrhythmogenesis. RESULTS: The first case had ventricular fibrillation repeatedly documented after a single premature atrial complex, produced left-sided conduction delay and simultaneous earliest activation of the left anterior fascicle (LAF) and left posterior fascicle (LPF). The LSF was ablated, resulting in an arrhythmia cure. The second case showed narrow QRS morphology during fascicular re-entrant tachycardia. The earliest mid-septal diastolic potentials had distal-to-proximal activation suggesting an LSF as a retrograde common pathway. The third case, with multiple ectopic Purkinje-related premature complexes exhibited earliest Purkinje potentials in the mid-septum, with subsequent anterograde activation of the LAF and LPF. Ablation of the LSF eliminated the premature ventricular complexes (PVCs). The fourth case demonstrated LPF and LAF PVCs. The His-left bundle activation showed earliest potentials at the proximal insertion of the left bundle during LPF PVCs, as well as a distal-to-proximal activation pattern during LAF PVC, suggestive of LSF involvement. The fifth case had focal non-re-entrant fascicular beats successfully ablated over the LSF. CONCLUSIONS: Involvement of the LSF is suspected with presentation of multiform fascicular and narrow QRS complex ventricular episodes of arrhythmia. Diagnoses and ablation require detailed mapping of the entire left sided conduction system.


Subject(s)
Catheter Ablation , Ventricular Premature Complexes , Bundle of His/surgery , Electrocardiography , Humans , Laboratories , Ventricular Premature Complexes/diagnosis , Ventricular Premature Complexes/surgery
6.
JACC Clin Electrophysiol ; 7(5): 662-670, 2021 05.
Article in English | MEDLINE | ID: mdl-33516710

ABSTRACT

OBJECTIVES: This study sought to identify acute changes in human atrial electrophysiology during alcohol exposure. BACKGROUND: The mechanism by which a discrete episode of atrial fibrillation (AF) occurs remains unknown. Alcohol appears to increase the risk for AF, providing an opportunity to study electrophysiologic effects that may render the heart prone to arrhythmia. METHODS: In this randomized, double-blinded, placebo-controlled trial, intravenous alcohol titrated to 0.08% blood alcohol concentration was compared with a volume and osmolarity-matched, masked, placebo in patients undergoing AF ablation procedures. Right, left, and pulmonary vein atrial effective refractory periods (AERPs) and conduction times were measured pre- and post-infusion. Isoproterenol infusions and burst atrial pacing were used to assess AF inducibility. RESULTS: Of 100 participants (50 in each group), placebo recipients were more likely to be diabetic (22% vs. 4%; p = 0.007) and to have undergone a prior AF ablation (36% vs. 22%; p = 0.005). Pulmonary vein AERPs decreased an average of 12 ms (95% confidence interval: 1 to 22 ms; p = 0.026) in the alcohol group, with no change in the placebo group (p = 0.98). Whereas no statistically significant differences in continuously assessed AERPs were observed, the proportion of AERP sites tested that decreased with alcohol (median: 0.5; interquartile range: 0.6 to 0.6) was larger than with placebo (median: 0.4; interquartile range: 0.2 to 0.6; p = 0.0043). No statistically significant differences in conduction times or in the proportion with inducible AF were observed. CONCLUSIONS: Acute exposure to alcohol reduces AERP, particularly in the pulmonary veins. These data demonstrate a direct mechanistic link between alcohol, a common lifestyle exposure, and immediate proarrhythmic effects in human atria. (How Alcohol Induces Atrial Tachyarrhythmias Study [HOLIDAY]; NCT01996943).


Subject(s)
Blood Alcohol Content , Pulmonary Veins , Cardiac Electrophysiology , Double-Blind Method , Heart Atria , Heart Conduction System , Humans
7.
J Cardiovasc Electrophysiol ; 31(12): 3232-3242, 2020 12.
Article in English | MEDLINE | ID: mdl-33107135

ABSTRACT

INTRODUCTION: Permanent junctional reciprocating tachycardia (PJRT) is a rare supraventricular tachycardia (SVT), typically involving a single decremental posteroseptal accessory pathway (AP). METHODS: Four patients with long RP SVT underwent electrophysiology (EP) study and ablation. The cases were reviewed. RESULTS: Case 1 recurred despite 3 prior ablations at the site of earliest retrograde atrial activation during orthodromic reciprocating tachycardia (ORT). Mapping during a repeat EP study demonstrated a prepotential in the coronary sinus (CS). Ablation over the earliest atrial activation in the CS resulted in dissociation of the potential from the atrium during sinus rhythm. The potential was traced back to the CS os and ablated. Case 2 underwent successful ablation at 6 o'clock on the mitral annulus (MA). ORT recurred and successful ablation was performed at 1 o'clock on the MA. Case 3 had tachycardia with variation in both V-A and A-H intervals which precluded the use of usual maneuvers so we used simultaneous atrial and ventricular pacing and introduced a premature atrial contraction with a closely coupled premature ventricular contraction. Case 4 had had two prior atrial fibrillation ablations with continued SVT over a decremental atrioventricular bypass tract that was successfully ablated at 5 o'clock on the tricuspid annulus. A second SVT consistent with a concealed nodoventricular pathway was successfully ablated at the right inferior extension of the AV nodal slow pathway. CONCLUSION: We describe challenging cases of PJRT by virtue of complex anatomy, diagnostic features, and multiple arrhythmia mechanisms.


Subject(s)
Catheter Ablation , Tachycardia, Reciprocating , Tachycardia, Supraventricular , Atrioventricular Node , Electrocardiography , Humans , Tachycardia, Reciprocating/diagnosis , Tachycardia, Reciprocating/surgery , Tachycardia, Supraventricular/diagnosis , Tachycardia, Supraventricular/surgery
8.
JACC Clin Electrophysiol ; 6(11): 1367-1376, 2020 10 26.
Article in English | MEDLINE | ID: mdl-33121665

ABSTRACT

OBJECTIVES: This study sought to prospectively study the development and then regression of premature ventricular contraction (PVC)-induced cardiomyopathy, with the hypothesis that structural left ventricular (LV) changes that are of potential clinical significance may endure beyond the period of exposure to PVCs. BACKGROUND: Recovery of LV function after eradication of PVCs in PVC-induced cardiomyopathy is incompletely defined. METHODS: Fifteen swine were exposed to: 1) 50% paced PVCs from the LV lateral epicardium for 12 weeks (LV PVC, n = 5); 2) no pacing for 12 weeks (Control, n = 5); or 3) 50% paced LV PVCs for 12 weeks followed by pacing cessation for 4 weeks (Recovery, n = 5). LV function was quantified biweekly in sinus rhythm with echocardiography. Dyssynchrony was measured from pressure-volume loops at baseline and terminal studies. LV fibrosis was quantified after sacrifice. RESULTS: LV ejection fraction during sinus rhythm fell between baseline and terminal studies in the LV PVC group (65.8 ± 3.0 to 39.3 ± 3.2; p < 0.05), whereas there was no significant change in the Control group (69.6 ± 3.0 to 72.2 ± 3.0; p = NS) or after Recovery (64.5 ± 3.4% to 61.4 ± 3.4%; p = NS) groups. There was a significant increase in LV dyssynchrony measured during sinus rhythm between baseline and terminal studies in the LV PVC group (4.0 ± 1.5% to 9.0 ± 1.5%; p < 0.05); there was a similar increase in dyssynchrony that persisted 4 weeks after PVC cessation in the Recovery group (4.4 ± 1.7% to 12.8 ± 1.7%; p < 0.05). After sacrifice, percent fibrosis was higher in the LV PVC group compared with Control (5.7 ± 0.3% vs. 3.0 ± 0.3%; p < 0.05) and remained elevated in Recovery (4.1 ± 0.3% vs. 3.0 ± 0.3%; p < 0.05) despite return to baseline LV ejection fraction. CONCLUSIONS: In a swine model of PVC-induced cardiomyopathy, cessation of PVCs for 4 weeks leads to normalization of LV systolic function but significant changes in myocardial fibrosis and LV dyssynchrony during sinus rhythm persist.


Subject(s)
Cardiomyopathies , Ventricular Premature Complexes , Animals , Fibrosis , Humans , Stroke Volume , Swine , Ventricular Function, Left
9.
JACC Clin Electrophysiol ; 6(7): 830-845, 2020 07.
Article in English | MEDLINE | ID: mdl-32703566

ABSTRACT

OBJECTIVES: This study sought to define the extent and spatial distribution of endocardial-epicardial dissociation (EED) in a swine model. BACKGROUND: The mechanisms underlying persistent atrial fibrillation (AF) remain unclear. METHODS: Sixteen swine underwent simultaneous endocardial and epicardial mapping using 32-electrode grid catheters. This included 6 swine with rapid atrial pacing-induced atrial remodeling. Three right atrial (RA) and 3 left atrial (LA) regions were mapped during sinus rhythm, atrial pacing, acute or persistent AF, and AF in the presence of pericardial acetylcholine. Unipolar electrogram recordings over 10-s epochs underwent offline phase analysis using customized software. Regional activation patterns on paired surfaces and the instantaneous phase at each matched electrode location were analyzed. EED was defined as paired electrodes out of phase by ≥20 ms. RESULTS: The mean distance between matched endocardial-epicardial electrode pairs was 4.4 ± 1.8 mm. During episodes of AF, rotational activations with ≥3 full rotations were not seen. EED was seen during 34.4 ± 16.4% of mapped time periods: LA > RA, persistent > acute AF in the LA, and acetylcholine-induced > acute AF in both atria (p < 0.05 for each). Most marked EED in persistent AF was in the LA appendage (47.2 ± 3.7%) and the LA posterior wall (50.3 ± 4.7%). CONCLUSIONS: Marked EED was seen in a swine model of AF, particularly during persistent AF. There was significantly more EED in the LA than the RA and, particularly, in the LA PW and LAA. Mapping approaches limited to the endocardium may not sufficiently characterize the complexity of AF.


Subject(s)
Atrial Fibrillation , Endocardium , Animals , Epicardial Mapping , Heart Atria , Pericardium , Swine
10.
Circ Arrhythm Electrophysiol ; 13(8): e008512, 2020 08.
Article in English | MEDLINE | ID: mdl-32634027

ABSTRACT

BACKGROUND: Endocardial-epicardial dissociation and focal breakthroughs in humans with atrial fibrillation (AF) have been recently demonstrated using activation mapping of short 10-second AF segments. In the current study, we used simultaneous endo-epi phase mapping to characterize endo-epi activation patterns on long segments of human persistent AF. METHODS: Simultaneous intraoperative mapping of endo- and epicardial lateral right atrium wall was performed in patients with persistent AF using 2 high-density grid catheters (16 electrodes, 3 mm spacing). Filtered unipolar and bipolar electrograms of continuous 2-minute AF recordings and electrodes locations were exported for phase analyses. We defined endocardial-epicardial dissociation as phase difference of ≥20 ms between paired endo-epi electrodes. Wavefronts were classified as rotations, single wavefronts, focal waves, or disorganized activity as per standard criteria. Endo-Epi wavefront patterns were simultaneously compared on dynamic phase maps. Complex fractionated electrograms were defined as bipolar electrograms with ≥5 directional changes occupying at least 70% of sample duration. RESULTS: Fourteen patients with persistent AF undergoing cardiac surgery were included. Endocardial-epicardial dissociation was seen in 50.3% of phase maps with significant temporal heterogeneity. Disorganized activity (Endo: 41.3% versus Epi: 46.8%, P=0.0194) and single wavefronts (Endo: 31.3% versus Epi: 28.1%, P=0.129) were the dominant patterns. Transient rotations (Endo: 22% versus Epi: 19.2%, P=0.169; mean duration: 590±140 ms) and nonsustained focal waves (Endo: 1.2% versus Epi: 1.6%, P=0.669) were also observed. Apparent transmural migration of rotational activations (n=6) from the epi- to the endocardium was seen in 2 patients. Electrogram fractionation was significantly higher in the epicardium than endocardium (61.2% versus 51.6%, P<0.0001). CONCLUSIONS: Simultaneous endo-epi phase mapping of prolonged human persistent AF recordings shows significant Endocardial-epicardial dissociation marked temporal heterogeneity, discordant and transitioning wavefronts patterns and complex fractionations. No sustained focal activity was observed. Such complex 3-dimensional interactions provide insight into why endocardial mapping alone may not fully characterize the AF mechanism and why endocardial ablation may not be sufficient. Graphic Abstract: A graphic abstract is available for this article.


Subject(s)
Action Potentials , Atrial Fibrillation/diagnosis , Cardiac Catheterization , Endocardium/physiopathology , Epicardial Mapping , Heart Rate , Pericardium/physiopathology , Aged , Atrial Fibrillation/physiopathology , Cardiac Catheterization/instrumentation , Cardiac Catheters , Epicardial Mapping/instrumentation , Female , Humans , Male , Middle Aged , Predictive Value of Tests , Time Factors
11.
Heart Rhythm ; 17(3): 476-484, 2020 03.
Article in English | MEDLINE | ID: mdl-31606463

ABSTRACT

BACKGROUND: Ventricular bipolar voltage values <0.5 and <1.0/1.5 mV (epi- and endocardium) correlating with dense scar and border zone, respectively, were established using a 3.5-mm tip catheter. Novel microelectrode catheters promise improved mapping resolution; however, whether standard voltage criteria apply to catheters with smaller electrode size and interelectrode distance remains unclear. OBJECTIVE: The purpose of this study was to determine whether traditional bipolar voltage criteria for scar apply during substrate mapping with a microelectrode catheter. METHODS: Paired bipolar and microbipolar voltage values were acquired from control swine (n = 2) using the microelectrode catheter and assessed for systemic differences. In a postinfarction swine model (n = 6), scar characteristics were compared between the bipolar maps and microbipolar maps using both standard and adjusted voltage criteria derived from the control animals. RESULTS: In control swine, although 5th percentile values for bipolar and microbipolar voltage were similar (1.12 vs 1.22 mV [left ventricular (LV) endo]; 0.88 mV vs 0.98 mV [epi]), median values were significantly greater when acquired by microbipolar electrodes (3.60 vs 6.76 mV, P = .002 [LV endo]; 2.61 vs 2.72 mV, P = .02 [epi]). Microbipolar values were systematically larger by 2.0× and 1.4× in the LV endocardium and epicardium, respectively. Application of standard voltage values to microbipolar maps in postinfarct swine underestimated scar area by approximately 41% in the LV endocardium (13.7 vs 33.4 cm2, P = .004). CONCLUSION: Bipolar voltage values acquired from microelectrodes are systemically larger than those acquired from standard catheters. New reference values should be established for these novel catheters.


Subject(s)
Body Surface Potential Mapping/methods , Cicatrix/diagnosis , Myocardium/pathology , Tachycardia, Ventricular/diagnosis , Animals , Cicatrix/physiopathology , Disease Models, Animal , Microelectrodes , Reference Standards , Swine , Tachycardia, Ventricular/physiopathology
12.
Circ Arrhythm Electrophysiol ; 12(9): e007337, 2019 09.
Article in English | MEDLINE | ID: mdl-31505948

ABSTRACT

BACKGROUND: Nodofascicular and nodoventricular (NFV) accessory pathways connect the atrioventricular node and the Purkinje system or ventricular myocardium, respectively. Concealed NFV pathways participate as the retrograde limb of supraventricular tachycardia (SVT). Manifest NFV pathways can comprise the anterograde limb of wide-complex SVT but are quite rare. The purpose of this report is to highlight the electrophysiological properties and sites of ablation for manifest NFV pathways. METHODS: Eight patients underwent electrophysiology studies for wide-complex tachycardia (3), for narrow-complex tachycardia (1), and preexcitation (4). RESULTS: NFV was an integral part of the SVT circuit in 3 patients. Cases 1 to 2 were wide-complex tachycardia because of manifest NFV SVT. Case 3 was a bidirectional NFV that conducted retrograde during concealed NFV SVT and anterograde causing preexcitation during atrial pacing. NFV was a bystander during atrioventricular node re-entrant tachycardia, atrial fibrillation, atrial flutter, and orthodromic atrioventricular re-entrant tachycardia in 4 cases and caused only preexcitation in 1. Successful NFV ablation was achieved empirically in the slow pathway region in 1 case. In 5 cases, the ventricular insertion was mapped to the slow pathway region (2 cases) or septal right ventricle (3 cases). The NFV was not mapped in cases 5 and 7 because of its bystander role. QRS morphology of preexcitation predicted the right ventricle insertion sites in 4 of the 5 cases in which it was mapped. During follow-up, 1 patient noted recurrent palpitations but no documented SVT. CONCLUSIONS: Manifest NFV may be critical for wide-complex tachycardia/manifest NFV SVT, act as the retrograde limb for narrow-complex tachycardia/concealed NFV SVT, or cause bystander preexcitation. Ablation should initially target the slow pathway region, with mapping of the right ventricle insertion site if slow pathway ablation is not successful. The QRS morphology of maximal preexcitation may be helpful in predicting successful right ventricle ablation site.


Subject(s)
Accessory Atrioventricular Bundle/physiopathology , Atrioventricular Node/physiopathology , Bundle of His/physiopathology , Catheter Ablation/methods , Pre-Excitation Syndromes/surgery , Tachycardia, Atrioventricular Nodal Reentry/surgery , Accessory Atrioventricular Bundle/surgery , Adult , Aged , Atrioventricular Node/surgery , Bundle of His/surgery , Child , Electrocardiography , Female , Heart Atria/physiopathology , Humans , Male , Middle Aged , Pre-Excitation Syndromes/physiopathology , Tachycardia, Atrioventricular Nodal Reentry/physiopathology , Young Adult
13.
JACC Clin Electrophysiol ; 5(4): 448-458, 2019 04.
Article in English | MEDLINE | ID: mdl-31000098

ABSTRACT

OBJECTIVES: The goal of this study was to characterize, in detail, focal atrial tachycardia (AT) arising from the crista terminalis to investigate associations with other atrial arrhythmia and to define long-term ablation outcomes. BACKGROUND: The crista terminalis is known to be the most common site of origin for focal AT, but it is not well characterized. METHODS: This study retrospectively identified a total of 548 ablation procedures for AT performed at a single center over a 16-year period, of which 171 were arising from the crista terminalis. RESULTS: Compared with patients with other AT sites of origin, crista terminalis AT patients were older (57.3 vs. 47.3 years), more commonly female (72.9% vs. 59.1%), were more commonly associated with coexistent atrioventricular nodal re-entry tachycardia (17.1% vs. 9.7%), and were more likely to be inducible with programmed stimulation (81.5% vs. 58.9%). There was preferential conduction in the superior-inferior axis along the crista terminalis. Acute ablation success rate was high (92.2%) and improved significantly when three-dimensional mapping was used (98.5%). Recurrence in the first 12 months after a successful ablation was 9.7%. Only 2 patients developed atrial fibrillation over the long-term follow-up of >7 years. CONCLUSIONS: This large series characterized the clinical and electrophysiological features and immediate and long-term ablation outcomes for AT originating from the crista terminalis. Features of the tachycardia suggest that age-related localized remodeling of the crista terminalis causes a superficial endocardial zone of conduction slowing leading to re-entry. Ablation outcomes were good, with long-term freedom from atrial arrhythmia.


Subject(s)
Catheter Ablation , Heart Atria , Tachycardia , Atrial Fibrillation , Catheter Ablation/adverse effects , Catheter Ablation/statistics & numerical data , Electrocardiography , Female , Heart Atria/physiopathology , Heart Atria/surgery , Humans , Male , Middle Aged , Postoperative Complications , Retrospective Studies , Tachycardia/diagnosis , Tachycardia/physiopathology , Tachycardia/surgery , Treatment Outcome
14.
Heart Lung Circ ; 28(1): 178-190, 2019 Jan.
Article in English | MEDLINE | ID: mdl-30322758

ABSTRACT

Frequent ventricular ectopy is a common clinical presentation in patients suffering idiopathic ventricular outflow tract arrhythmias. These are focal arrhythmias that generally occur in patients without structural heart disease and share a predilection for characteristic anatomic sites of origin. Mechanistically, they are generally due to cyclic adenosine monophosphate (cAMP)-mediated triggered activity. As a result, there is typically an exercise or catecholamine related mode of induction and often a sensitivity to suppression with adenosine. Treatment options include clinical surveillance, medical therapy with anti-arrhythmic agents or catheter ablation. Medical therapy may offer symptomatic benefit but may have side-effects and usually results in burden reduction rather than eradication of ectopy. Catheter ablation using contemporary mapping techniques, whilst associated with some inherent procedural risk, is a potentially curative and safe option in most patients. Although usually associated with a good prognosis, some patients may develop an ectopy-mediated cardiomyopathy or, rarely, ectopy-induced polymorphic ventricular arrhythmias; catheter ablation is the treatment of choice in those patients.


Subject(s)
Catheter Ablation , Electrocardiography , Heart Ventricles/physiopathology , Ventricular Premature Complexes , Global Health , Humans , Incidence , Ventricular Premature Complexes/epidemiology , Ventricular Premature Complexes/physiopathology , Ventricular Premature Complexes/surgery
15.
Int J Cardiol ; 279: 84-89, 2019 Mar 15.
Article in English | MEDLINE | ID: mdl-30442375

ABSTRACT

BACKGROUND: The key drivers of symptom severity and health-related quality of life (hr-QOL) in patients with atrial fibrillation (AF) remain unclear. We aimed to determine the relative contribution to symptom severity and hr-QOL of clinical factors including left ventricular (LV) diastolic function and ventricular rate control during AF and of psychological functioning. METHODS: Seventy-eight consecutive patients with symptomatic AF and preserved LV systolic function underwent detailed evaluation of i) AF symptom severity and hr-QOL; ii) clinical factors including left ventricular (LV) diastolic function, AF burden, and ventricular rate during AF and iii) state and trait aspects of psychological functioning. RESULTS: Moderate-to-severe AF-related symptoms were reported by 64% of the study population whilst 36% reported no more than mild symptoms. Worse symptom severity was associated with a higher score on the Perceived Stress Scale (16.7 ±â€¯4.4 vs. 5.4 ±â€¯4.4, p < 0.0001) and higher prevalence of the Type D Personality (20/50 vs. 4/28, p = 0.012). In multivariable models, only a predisposition to subjectively appraise life situations as stressful (higher PSS score) and a personality with a higher degree of negative affectivity and social inhibition (higher TDPS score) were independent predictors of higher AF symptom severity and poorer hr-QOL. No clinical factors including AF burden, ventricular rates during AF or LV diastolic function were significant predictors of AF-specific symptoms or hr-QOL. CONCLUSION: In a tertiary AF population with preserved LV systolic function, only psychological functioning consistently predicts both AF-related symptoms and hr-QOL. LV diastolic function, AF burden, and ventricular rate during AF are not independent predictors.


Subject(s)
Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/psychology , Personality/physiology , Quality of Life/psychology , Severity of Illness Index , Ventricular Function, Left/physiology , Aged , Atrial Fibrillation/physiopathology , Female , Humans , Male , Middle Aged , Predictive Value of Tests , Prospective Studies
16.
J Am Coll Cardiol ; 72(23 Pt A): 2870-2882, 2018 12 11.
Article in English | MEDLINE | ID: mdl-30522650

ABSTRACT

BACKGROUND: The pathophysiology of cardiomyopathy associated with premature ventricular contractions (PVCs) remains unclear. OBJECTIVES: This study prospectively explored cardiomyopathy development in a swine model of paced ectopic beats. METHODS: A total of 35 swine underwent pacemaker implantation. A group exposed to paced bigeminy from the right ventricular apex (RVA) for 14 weeks (RVA PVC) (n = 10) were compared with a group exposed to regular pacing from the RVA at 140 beats/min (RV-140) (n = 5) and a control group (n = 5). To test the role of ectopic beat dyssynchrony, further groups were exposed for 12 weeks to bigeminy from the right ventricular free wall (RVFW PVC) (n = 5), the left ventricular epicardium (LV Epi PVC) (n = 5) or the right atrium (premature atrial complex) (n = 5). RESULTS: After 14 weeks, the mean left ventricular ejection fraction (LVEF) was significantly lower in the RVA PVC group than in the RV-140 or control groups (p < 0.05). LVEF declined significantly in the LV Epi PVC (65.2 ± 2.4% to 39.7 ± 3.0%; p < 0.01) and RVFW PVC (66.1 ± 2.6% to 48.6 ± 2.7%; p < 0.01) groups, with final LVEF significantly lower and ventricular fibrosis significantly higher in the LV Epi PVC group compared with all others (p < 0.05). Protein levels of pRyR2, NCX-1, CaMKII-α, and PLN were up-regulated and levels of SERCA2a were down-regulated in the LV Epi PVC group compared with the control group (p < 0.05). Longer ectopic beat QRS duration and greater LV dyssynchrony were significantly associated with larger declines in LV systolic function. CONCLUSIONS: In a swine model of paced ectopic beats, PVC-induced cardiomyopathy is phenotypically distinct from a tachycardia-induced cardiomyopathy. Cardiomyopathy severity is strongly associated with severity of the hemodynamic derangement associated with the paced ectopic beats, particularly the extent of LV dyssynchrony.


Subject(s)
Cardiomyopathies/diagnosis , Cardiomyopathies/physiopathology , Ventricular Dysfunction, Left/diagnosis , Ventricular Dysfunction, Left/physiopathology , Ventricular Premature Complexes/diagnosis , Ventricular Premature Complexes/physiopathology , Animals , Predictive Value of Tests , Swine , Swine, Miniature
17.
J Am Heart Assoc ; 7(18): e005502, 2018 09 18.
Article in English | MEDLINE | ID: mdl-30371197

ABSTRACT

Background An association between atrial fibrillation ( AF ), anxiety, and depression is recognized, but the spectrum of psychological distress remains unclear. We aimed to characterize the severity and predictors of distress associated with AF in a tertiary population and its response to AF management. Methods and Results Seventy-eight patients with symptomatic AF underwent evaluation, including of AF symptom severity, health-related quality of life, psychological distress, suicidal ideation, and specific personality traits. Twenty participants underwent AF ablation and 58 were managed medically, with repeat assessments at 4, 8, and 12 months. Severe distress (Hospital Anxiety and Depression Scale score, ≥15/42) was identified in 27 of 78 (35%). Independent predictors were a personality marked by vulnerability to stress (Perceived Stress Scale: R2, 0.54; ß=0.7±0.1; t=7.8; P<0.001) and 1 marked by negativity/social inhibition (Type D Personality Scale: R2, 0.47; ß=0.7±0.1; t=6.7; P<0.001). Suicidal ideation was reported by 16 of 78 (20%) and was predicted by personality traits (Perceived Stress Scale score: R2, 0.35; odds ratio, 1.22±0.06; P<0.001; Type D Personality Scale score: R2, 0.48; odds ratio, 1.43±0.14; P<0.001). Effective AF ablation (median AF burden 1% [0-1%] over 12 months) was associated with significant reductions in distress (Hospital Anxiety and Depression Scale score, 13.9±1.8 to 4.3±1.8; P<0.05) and prevalence of suicidal ideation (30-5%; P=0.02). Conclusions There was a high prevalence of severe psychological distress (35%) and of suicidal ideation (20%) in a tertiary AF population, with personality traits predicting both. Effective AF ablation was associated with significant improvements, suggesting AF itself may be a treatable causative factor of distress.


Subject(s)
Atrial Fibrillation/complications , Attitude to Health , Disease Management , Stress, Psychological/epidemiology , Suicidal Ideation , Adolescent , Adult , Aged , Aged, 80 and over , Atrial Fibrillation/psychology , Australia/epidemiology , Female , Follow-Up Studies , Humans , Male , Middle Aged , Prevalence , Quality of Life , Risk Factors , Severity of Illness Index , Stress, Psychological/etiology , Stress, Psychological/therapy , Surveys and Questionnaires , Young Adult
18.
J Cardiovasc Electrophysiol ; 29(10): 1371-1378, 2018 10.
Article in English | MEDLINE | ID: mdl-30016007

ABSTRACT

INTRODUCTION: Outcome of patients undergoing catheter ablation of atrial fibrillation (AF) varies widely. We sought to investigate whether parameters derived from the spectral analysis of surface ECG and intracardiac AF electrograms can predict outcome in patients referred for pulmonary vein isolation (PVI). METHODS: We performed spectral analysis on the surface ECG and intracardiac electrograms from patients referred for AF ablation. After filtering and QRST subtraction, we measured the dominant frequency (DF), regularity index (RI) and the organizational index (OI) of fibrillatory electrograms and determined their value for predicting AF recurrence after ablation. A subjective, blinded prediction based on the surface ECG was also performed. RESULTS: We analyzed data from 153 PVI procedures in 140 patients (67.1% with persistent or longstanding AF). In a multivariable model, DF in the right atrium (RA) and distal coronary sinus (CSd)-to-RA DF gradient predicted AF recurrence (OR, 3.52, P = 0.023 and OR, 0.2, P = 0.034, respectively). DF in RA and CSd to RA DF gradient had a good predictive value for PVI outcome (area under the curve [AUC] of 0.73, P = 0.007 and 0.74, P = 0.007, respectively). These performed better than the subjective predictions of experienced electrophysiologists ( P = 0.2). CONCLUSIONS: Higher RA DF, lower CSd to RA DF gradient predicted recurrence after AF ablation. These spectral measures suggest a more remodeled atrial substrate and may provide simple tools for risk stratification or predict the need for additional substrate modification in patients referred for AF ablation.


Subject(s)
Action Potentials , Atrial Fibrillation/surgery , Catheter Ablation/adverse effects , Electrocardiography , Electrophysiologic Techniques, Cardiac , Heart Rate , Pulmonary Veins/surgery , Aged , Atrial Fibrillation/diagnosis , Atrial Fibrillation/physiopathology , Female , Humans , Male , Middle Aged , Predictive Value of Tests , Pulmonary Veins/physiopathology , Recurrence , Risk Assessment , Risk Factors , Signal Processing, Computer-Assisted , Time Factors , Treatment Outcome
19.
JACC Clin Electrophysiol ; 4(1): 72-83, 2018 01.
Article in English | MEDLINE | ID: mdl-29600788

ABSTRACT

OBJECTIVES: This study sought to validate a 3-dimensional (3D) phase mapping system and determine the distribution of dominant propagation patterns in persistent atrial fibrillation (AF). BACKGROUND: Currently available systems display phase as simplified 2-dimensional maps. We developed a novel 3D phase mapping system that uses the 3D location of basket catheter electrodes and the patient's 3D left atrial surface geometry to interpolate phase and create a 3D representation of phase progression. METHODS: Six-min AF recordings from the left atrium were obtained in 14 patients using the Constellation basket catheter and analyzed offline. Exported signals underwent both phase and traditional activation analysis and were then visualized using a novel 3D mapping system. Analysis involved: 1) validation of phase analysis by comparing beat-to-beat AF cycle length calculated using phase inversion with that determined from activation timing in the same 20-s segment; 2) validation of 3D phase by comparing propagation patterns observed using 3D phase with 3D activation in the same 1-min segment; and 3) determining the distribution of dominant propagation patterns in 6-min recordings using 3D phase. RESULTS: There was strong agreement of beat-to-beat AF cycle length between activation analysis and phase inversion (R2 = 0.91). There was no significant difference between 3D activation and 3D phase in mean percentage of propagation patterns classified as single wavefronts (p = 0.99), focal activations (p = 0.26), disorganized activity (p = 0.76), or multiple wavefronts (p = 0.70). During prolonged 3D phase, single wavefronts were the most common propagation pattern (50.2%). A total of 34 rotors were seen in 9 of 14 patients. All rotors were transient with mean duration of 1.0 ± 0.6 s. Rotors were only observed in areas of high electrode density where the interelectrode distance was significantly shorter than nonrotor sites (7.4 [interquartile range: 6.3 to 14.6] vs. 15.3 mm [interquartile range: 10.1 to 22.2]; p < 0.001). CONCLUSIONS: During prolonged 3D phase mapping, transient rotors were observed in 64% of patients and reformed at the same anatomic location in 44% of patients. The electrode density of the basket catheter may limit the detection of rotors.


Subject(s)
Atrial Fibrillation , Electrocardiography/methods , Epicardial Mapping/methods , Imaging, Three-Dimensional/methods , Aged , Atrial Fibrillation/diagnosis , Atrial Fibrillation/physiopathology , Female , Heart Atria/physiopathology , Heart Conduction System/physiopathology , Humans , Male , Middle Aged
20.
Heart Rhythm ; 15(2): 182-192, 2018 02.
Article in English | MEDLINE | ID: mdl-28917553

ABSTRACT

BACKGROUND: Current phase mapping systems for atrial fibrillation create 2-dimensional (2D) maps. This process may affect the accurate detection of rotors. We developed a 3-dimensional (3D) phase mapping technique that uses the 3D locations of basket electrodes to project phase onto patient-specific left atrial 3D surface anatomy. OBJECTIVE: We sought to determine whether rotors detected in 2D phase maps were present at the corresponding time segments and anatomical locations in 3D phase maps. METHODS: One-minute left atrial atrial fibrillation recordings were obtained in 14 patients using the basket catheter and analyzed off-line. Using the same phase values, 2D and 3D phase maps were created. Analysis involved determining the dominant propagation patterns in 2D phase maps and evaluating the presence of rotors detected in 2D phase maps in the corresponding 3D phase maps. RESULTS: Using 2D phase mapping, the dominant propagation pattern was single wavefront (36.6%) followed by focal activation (34.0%), disorganized activity (23.7%), rotors (3.3%), and multiple wavefronts (2.4%). Ten transient rotors were observed in 9 of 14 patients (64%). The mean rotor duration was 1.1 ± 0.7 seconds. None of the 10 rotors observed in 2D phase maps were seen at the corresponding time segments and anatomical locations in 3D phase maps; 4 of 10 corresponded with single wavefronts in 3D phase maps, 2 of 10 with 2 simultaneous wavefronts, 1 of 10 with disorganized activity, and in 3 of 10 there was no coverage by the basket catheter at the corresponding 3D anatomical location. CONCLUSION: Rotors detected in 2D phase maps were not observed in the corresponding 3D phase maps. These findings may have implications for current systems that use 2D phase mapping.


Subject(s)
Atrial Fibrillation/diagnosis , Body Surface Potential Mapping/methods , Heart Atria/physiopathology , Heart Conduction System/physiopathology , Imaging, Three-Dimensional , Atrial Fibrillation/physiopathology , Female , Humans , Male , Middle Aged , Time Factors
SELECTION OF CITATIONS
SEARCH DETAIL
...