Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Rep Pract Oncol Radiother ; 26(6): 1029-1034, 2021.
Article in English | MEDLINE | ID: mdl-34992877

ABSTRACT

BACKGROUND: The availability of linear accelerators (linac) for research purposes is often limited and therefore alternative radiation sources are needed to conduct radiobiological research. The National Centre for Radiation Research in Poland recently developed an intraoperative mobile linac that enables electron irradiation at energies ranging from 4 to 12 MeV and dose rates of 5 or 10 Gy/min. The present study was conducted to evaluate the electron beam parameters of this intraoperative linac and to verify the set-up to evaluate out-of-field doses in a water phantom, which were determined through dosimetric and biological response measurements. MATERIALS AND METHODS: The distribution of radiation doses along and across the radiation beam were measured in a water phantom using a semiconductor detector and absolute doses using an ionisation chamber. Two luminal breast cancer cell lines (T-47D and HER2 positive SK-BR-3) were placed in the phantom to study radiation response at doses ranging from 2 to 10 Gy. Cell response was measured by clonogenic assays. RESULTS AND CONCLUSION: The electron beam properties, including depth doses and profiles, were within expected range for the stated energies. These results confirm the viability of this device and set-up as a source of megavoltage electrons to evaluate the radiobiological response of tumour cells.

2.
J Vis Exp ; (160)2020 06 09.
Article in English | MEDLINE | ID: mdl-32597879

ABSTRACT

The purpose of the manuscript is to provide a step-by-step protocol for performing immunofluorescence microscopy to study the radiation-induced DNA damage response induced by neutron-gamma mixed-beam used in boron neutron capture therapy (BNCT). Specifically, the proposed methodology is applied for the detection of repair proteins activation which can be visualized as foci using antibodies specific to DNA double-strand breaks (DNA-DSBs). DNA repair foci were assessed by immunofluorescence in colon cancer cells (HCT-116) after irradiation with the neutron-mixed beam. DNA-DSBs are the most genotoxic lesions and are repaired in mammalian cells by two major pathways: non-homologous end-joining pathway (NHEJ) and homologous recombination repair (HRR). The frequencies of foci, immunochemically stained, for commonly used markers in radiobiology like γ-H2AX, 53BP1 are associated with DNA-DSB number and are considered as efficient and sensitive markers for monitoring the induction and repair of DNA-DSBs. It was established that γ-H2AX foci attract repair proteins, leading to a higher concentration of repair factors near a DSB. To monitor DNA damage at the cellular level, immunofluorescence analysis for the presence of DNA-PKcs representative repair protein foci from the NHEJ pathway and Rad52 from the HRR pathway was planned. We have developed and introduced a reliable immunofluorescence staining protocol for the detection of radiation-induced DNA damage response with antibodies specific for repair factors from NHEJ and HRR pathways and observed radiation-induced foci (RIF). The proposed methodology can be used for investigating repair protein that is highly activated in the case of neutron-mixed beam radiation, thereby indicating the dominance of the repair pathway.


Subject(s)
Colonic Neoplasms/diagnostic imaging , Colonic Neoplasms/genetics , DNA Damage/immunology , DNA Repair/immunology , Fluorescent Antibody Technique/methods , Humans
SELECTION OF CITATIONS
SEARCH DETAIL
...