Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 76
Filter
3.
Article in English | MEDLINE | ID: mdl-38738814

ABSTRACT

INTRODUCTION: Ablation of scar-related reentrant atrial tachycardia (SRRAT) involves identification and ablation of a critical isthmus. A graph convolutional network (GCN) is a machine learning structure that is well-suited to analyze the irregularly-structured data obtained in mapping procedures and may be used to identify potential isthmuses. METHODS: Electroanatomic maps from 29 SRRATs were collected, and custom electrogram features assessing key tissue and wavefront properties were calculated for each point. Isthmuses were labeled off-line. Training data was used to determine the optimal GCN parameters and train the final model. Putative isthmus points were predicted in the training and test populations and grouped into proposed isthmus areas based on density and distance thresholds. The primary outcome was the distance between the centroids of the true and closest proposed isthmus areas. RESULTS: A total of 193 821 points were collected. Thirty isthmuses were detected in 29 tachycardias among 25 patients (median age 65.0, 5 women). The median (IQR) distance between true and the closest proposed isthmus area centroids was 8.2 (3.5, 14.4) mm in the training and 7.3 (2.8, 16.1) mm in the test group. The mean overlap in areas, measured by the Dice coefficient, was 11.5 ± 3.2% in the training group and 13.9 ± 4.6% in the test group. CONCLUSION: A GCN can be trained to identify isthmus areas in SRRATs and may help identify critical ablation targets.

4.
Europace ; 26(4)2024 Mar 30.
Article in English | MEDLINE | ID: mdl-38587017

ABSTRACT

In the last three decades, ablation of atrial fibrillation (AF) has become an evidence-based safe and efficacious treatment for managing the most common cardiac arrhythmia. In 2007, the first joint expert consensus document was issued, guiding healthcare professionals involved in catheter or surgical AF ablation. Mounting research evidence and technological advances have resulted in a rapidly changing landscape in the field of catheter and surgical AF ablation, thus stressing the need for regularly updated versions of this partnership which were issued in 2012 and 2017. Seven years after the last consensus, an updated document was considered necessary to define a contemporary framework for selection and management of patients considered for or undergoing catheter or surgical AF ablation. This consensus is a joint effort from collaborating cardiac electrophysiology societies, namely the European Heart Rhythm Association, the Heart Rhythm Society, the Asia Pacific Heart Rhythm Society, and the Latin American Heart Rhythm Society .


Subject(s)
Atrial Fibrillation , Catheter Ablation , Humans , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Latin America , Treatment Outcome , Catheters , Asia , Catheter Ablation/adverse effects , Catheter Ablation/methods
6.
Article in English | MEDLINE | ID: mdl-38609733

ABSTRACT

In the last three decades, ablation of atrial fibrillation (AF) has become an evidence-based safe and efficacious treatment for managing the most common cardiac arrhythmia. In 2007, the first joint expert consensus document was issued, guiding healthcare professionals involved in catheter or surgical AF ablation. Mounting research evidence and technological advances have resulted in a rapidly changing landscape in the field of catheter and surgical AF ablation, thus stressing the need for regularly updated versions of this partnership which were issued in 2012 and 2017. Seven years after the last consensus, an updated document was considered necessary to define a contemporary framework for selection and management of patients considered for or undergoing catheter or surgical AF ablation. This consensus is a joint effort from collaborating cardiac electrophysiology societies, namely the European Heart Rhythm Association, the Heart Rhythm Society (HRS), the Asia Pacific HRS, and the Latin American HRS.

7.
J Cardiovasc Electrophysiol ; 35(1): 130-135, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37975539

ABSTRACT

INTRODUCTION: Cavo-tricuspid isthmus (CTI) dependent atrial flutter (AFL) is one of the most common atrial arrhythmias involving the right atrium (RA) for which radiofrequency catheter ablation has been widely used as a therapy of choice. However, there is limited data on the effect of this intervention on cardiac size and function. METHODS: A retrospective study was conducted on 468 patients who underwent ablation for CTI dependent typical AFL at a single institution between 2010 and 2019. After excluding patients with congenital or rheumatic heart disease, heart transplant recipients, or those without baseline echocardiogram, a total of 130 patients were included in the analysis. Echocardiographic data were analyzed at baseline before ablation, and at early follow-up within 1-year postablation. Follow-up echocardiographic data was available for 55 patients. RESULTS: Of the 55 patients with CTI-AFL, the mean age was 64.2 ± 14.8 years old with 14.5% (n = 8) female. The average left ventricular ejection fraction (LVEF) significantly improved on follow-up echo (40.2 ± 16.9 to 50.4 ± 14.9%, p < .0001), of which 50% of patients had an improvement in LVEF of at least 10%. There was a significant reduction in left atrial volume index (82.74 ± 28.5 to 72.96 ± 28 mL/m2 , p = .008) and RA volume index (70.62 ± 25.6 to 64.15 ± 31 mL/m2 , p = .046), and a significant improvement in left atrial reservoir strain (13.04 ± 6.8 to 19.10 ± 7.7, p < .0001). CONCLUSIONS: Patients who underwent CTI dependent AFL ablation showed an improvement in cardiac size and function at follow-up evaluation. While long-term results are still unknown, these findings indicate that restoration of sinus rhythm in patients with typical AFL is associated with improvement in atrial size and left ventricular function.


Subject(s)
Atrial Flutter , Catheter Ablation , Humans , Female , Middle Aged , Aged , Atrial Flutter/diagnostic imaging , Atrial Flutter/surgery , Retrospective Studies , Stroke Volume , Ventricular Function, Left , Catheter Ablation/adverse effects , Catheter Ablation/methods , Treatment Outcome
8.
Am J Cardiol ; 213: 146-150, 2024 Feb 15.
Article in English | MEDLINE | ID: mdl-38008349

ABSTRACT

Successful synchronized direct current cardioversion (DCCV) requires adequate current delivery to the heart. However, adequate current for successful DCCV has not yet been established. Transmyocardial current depends on 2 factors: input energy and transthoracic impedance (TTI). Although factors affecting TTI have been studied in animal models, factors affecting TTI in humans have not been well established. Herein, we explored the potential factors that affect TTI in humans. A retrospective review of patients who underwent DCCV at a large quaternary medical center between October 2019 and August 2021 was conducted. Pertinent clinical information, including demographics, echocardiography findings, laboratory findings, and body characteristics, was collected. Cardioversion details, including joules delivered and TTI, were recorded by the defibrillator for each patient's first shock. Predictors of thoracic impedance were assessed using regression analysis. A total of 220 patients (29% women) were included in the analysis; 143 of the patients (65%) underwent DCCV for atrial fibrillation and 77 (35%) underwent DCCV for atrial flutter. The mean impedance in our population was 73 ± 18 Ω. In a regression model with high impedance defined as the upper quartile of our cohort, body mass index (BMI), female sex, obstructive sleep apnea, and chronic kidney disease (all p values <0.05) were significantly associated with high impedance. According to a receiver operating characteristic analysis, BMI has a high predictive value for high impedance, with an area under the curve of 0.76. In conclusion, our study reveals that elevated BMI, female sex, sleep apnea, and chronic kidney disease were predictors of higher TTI. These factors may help determine the appropriate initial shock energy in patients who underwent DCCV for atrial fibrillation and flutter.


Subject(s)
Atrial Fibrillation , Atrial Flutter , Renal Insufficiency, Chronic , Humans , Female , Male , Electric Countershock , Atrial Fibrillation/complications , Cardiography, Impedance , Atrial Flutter/therapy , Renal Insufficiency, Chronic/complications
9.
J Interv Card Electrophysiol ; 67(2): 409-424, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38038816

ABSTRACT

BACKGROUND: Esophageal perforation and fistula formation are rare but serious complications following atrial fibrillation ablation. In this review article, we outline the incidence, pathophysiology, predictors, and preventative strategies of this dreaded complication. METHODS: We conducted an electronic search in 10 databases/electronic search engines to access relevant publications. All articles reporting complications following atrial fibrillation ablation, including esophageal injury and fistula formation, were included for systematic review. RESULTS: A total of 130 manuscripts were identified for the final review process. The overall incidence of esophageal injury following atrial fibrillation ablation was significantly higher with thermal ablation modalities (radiofrequency 5-40%, cryoballoon 3-25%, high-intensity focused ultrasound < 10%) as opposed to non-thermal ablation modalities (no cases reported to date). The incidence of esophageal perforation and fistula formation with the use of thermal ablation modalities is estimated to occur in less than 0.25% of all atrial fibrillation ablation procedures. The use of luminal esophageal temperature monitoring probe and mechanical esophageal deviation showed protective effect toward reducing the incidence of this complication. The prognosis is very poor for patients who develop atrioesophageal fistula, and the condition is rapidly fatal without surgical intervention. CONCLUSIONS: Esophageal perforation and fistula formation following atrial fibrillation ablation are rare complications with poor prognosis. Various strategies have been proposed to protect the esophagus and reduce the incidence of this fearful complication. Pulsed field ablation is a promising new ablation technology that may be the future answer toward reducing the incidence of esophageal complications.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Esophageal Fistula , Esophageal Perforation , Humans , Esophageal Perforation/complications , Esophageal Perforation/surgery , Esophageal Fistula/epidemiology , Esophageal Fistula/etiology , Esophageal Fistula/surgery , Prognosis , Catheter Ablation/adverse effects , Catheter Ablation/methods , Heart Atria/surgery
10.
Comput Methods Programs Biomed ; 241: 107764, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37597351

ABSTRACT

INTRODUCTION: A quantitative analysis of the components of reentrant ventricular tachycardia (VT) circuitry could improve understanding of its onset and perpetuation. METHOD: In 19 canine experiments, the left anterior descending coronary artery was ligated to generate a subepicardial infarct. The border zone resided at the epicardial surface of the anterior left ventricle and was mapped 3-5 days postinfarction with a 196-312 bipolar multielectrode array. Monomorphic VT was inducible by extrastimulation. Activation maps revealed an epicardial double-loop reentrant circuit and isthmus, causing VT. Several circuit parameters were analyzed: the coupling interval for VT induction, VT cycle length, the lateral isthmus boundary (LIB) lengths, and isthmus width and angle. RESULTS: The extrastimulus interval for VT induction and the VT cycle length were strongly correlated (p < 0.001). Both the extrastimulus interval and VT cycle length were correlated to the shortest LIB (p < 0.005). A derivation was developed to suggest that when conduction block at the shorter LIB is functional, the VT cycle length may depend on the local refractory period and the delay from wavefront pivot around the LIB. Isthmus width and angle were uncorrelated to other parameters. CONCLUSIONS: The shorter LIB is correlated to VT cycle length, hence its circuit loop may drive reentrant VT. The extrastimulation interval, VT cycle length, and shorter LIB are intertwined, and may depend upon the local refractory period. Isthmus width and angle are less correlated, perhaps being more related to electrical discontinuity caused by alterations in infarct shape at depth.


Subject(s)
Tachycardia, Ventricular , Animals , Dogs , Heart Ventricles , Coronary Vessels , Electricity
11.
JACC Clin Electrophysiol ; 9(9): 1964-1971, 2023 09.
Article in English | MEDLINE | ID: mdl-37480861

ABSTRACT

BACKGROUND: Permanent pacemakers (PPMs) may be necessary in up to 10% of patients after heart transplantation (HT). OBJECTIVES: The purpose of this study was to evaluate long-term outcomes and clinical courses of heart transplant recipients who received PPM. METHODS: All patients who required PPM after bicaval HT at Columbia University between January 2005 and December 2021 were included. Cases were compared to matched heart transplant recipients by age, sex, and year of transplantation. Patient and device characteristics including complications and device interrogations were reviewed. Outcomes of re-transplantation or graft failure/death were compared between groups. RESULTS: Of 1,082 heart transplant recipients, 41 (3.8%) received PPMs. The median time from transplantation to PPM was 118 days (IQR: 18-920 days). The most common indications were sinus node dysfunction (60%, n = 25) and atrioventricular (AV) nodal disease (41.5%, n = 17). Post-implantation complications included pocket hematoma (n = 3), lead under-sensing (n = 2), and pocket infection requiring explant (n = 1). Rates of death and re-transplantation at 10 years post-HT were similar between groups. In multivariable analysis, after adjustment for mechanical circulatory support, pretransplantation amiodarone use, donor ischemic time and age, only older donor age was associated with increased risk of PPM implantation (P = 0.03). There was a significant decrease in PPM placement after 2018 (1.2% vs 4.4%, P = 0.02), largely driven by a decline in early PPM placement. There were no differences in mortality or need for re-transplantation between groups. CONCLUSIONS: PPMs are implanted after HT for sinus and atrioventricular node dysfunctions with low incidence of device-related complications. Our study shows a decrease in PPM implantation after 2018, likely attributable to expectant management in the early postoperative period.


Subject(s)
Amiodarone , Heart Transplantation , Pacemaker, Artificial , Humans , Heart Transplantation/adverse effects , Cardiac Conduction System Disease , Hematoma , Pacemaker, Artificial/adverse effects
12.
Comput Biol Med ; 163: 107084, 2023 09.
Article in English | MEDLINE | ID: mdl-37302374

ABSTRACT

BACKGROUND: Direct current cardioversion (DCCV) is an established treatment to acutely convert atrial fibrillation (AF) to normal sinus rhythm. Yet, more than 70% of patients revert to AF shortly thereafter. Electromechanical Cycle Length Mapping (ECLM) is a high framerate, spectral analysis technique shown to non-invasively characterize electromechanical activation in paced canines and re-entrant flutter patients. This study assesses ECLM feasibility to map and quantify atrial arrhythmic electromechanical activation rates and inform on 1-day and 1-month DCCV response. METHODS: Forty-five subjects (30 AF; 15 healthy sinus rhythm (SR) controls) underwent transthoracic ECLM in four standard apical 2D echocardiographic views. AF patients were imaged within 1 h pre- and post-DCCV. 3D-rendered atrial ECLM cycle length (CL) maps and spatial CL histograms were generated. CL dispersion and percentage of arrhythmic CLs≤333ms across the entire atrial myocardium were computed transmurally. ECLM results were subsequently used as indicators of DCCV success. RESULTS: ECLM successfully confirmed the electrical atrial activation rates in 100% of healthy subjects (R2=0.96). In AF, ECLM maps localized the irregular activation rates pre-DCCV and confirmed successful post-DCCV with immediate reduction or elimination. ECLM metrics successfully distinguished DCCV 1-day and 1-month responders from non-responders, while pre-DCCV ECLM values independently predicted AF recurrence within 1-month post-DCCV. CONCLUSIONS: ECLM can characterize electromechanical activation rates in AF, quantify their extent, and identify and predict short- and long-term AF recurrence. ELCM constitutes thus a noninvasive arrhythmia imaging modality that can aid clinicians in simultaneous AF severity quantification, prediction of AF DCCV response, and personalized treatment planning.


Subject(s)
Atrial Fibrillation , Electric Countershock , Animals , Dogs , Electric Countershock/methods , Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/therapy , Heart Atria/diagnostic imaging , Echocardiography/methods , Treatment Outcome
13.
JACC Clin Electrophysiol ; 9(6): 851-861, 2023 06.
Article in English | MEDLINE | ID: mdl-37227361

ABSTRACT

BACKGROUND: Sinus rhythm electrical activation mapping can provide information regarding the ischemic re-entrant ventricular tachycardia (VT) circuit. The information gleaned may include the localization of sinus rhythm electrical discontinuities, which can be defined as arcs of disrupted electrical conduction with large activation time differences across the arc. OBJECTIVES: This study sought to detect and localize sinus rhythm electrical discontinuities that might be present in activation maps constructed from infarct border zone electrograms. METHODS: Monomorphic re-entrant VT with a double-loop circuit and central isthmus was repeatedly inducible by programmed electrical stimulation in the epicardial border zone of 23 postinfarction canine hearts. Sinus rhythm and VT activation maps were constructed from 196 to 312 bipolar electrograms acquired surgically at the epicardial surface and analyzed computationally. A complete re-entrant circuit was mappable from the epicardial electrograms of VT, and isthmus lateral boundary (ILB) locations were ascertained. The difference in sinus rhythm activation time across ILB locations, vs the central isthmus and vs the circuit periphery, was determined. RESULTS: Sinus rhythm activation time differences averaged 14.4 milliseconds across the ILB vs 6.5 milliseconds at the central isthmus and 6.4 milliseconds at the periphery (ie, the outer circuit loop) (P ≤ 0.001). Locations with large sinus rhythm activation difference tended to overlap ILB (60.3% ± 23.2%) compared with their overlap with the entire grid (27.5% ± 18.5%) (P < 0.001). CONCLUSIONS: Disrupted electrical conduction is evident as discontinuity in sinus rhythm activation maps, particularly at ILB locations. These areas may represent permanent fixtures relating to spatial differences in border zone electrical properties, caused in part by alterations in underlying infarct depth. The tissue properties producing sinus rhythm discontinuity at ILB may contribute to functional conduction block formation at VT onset.


Subject(s)
Myocardial Infarction , Tachycardia, Ventricular , Animals , Dogs , Heart Conduction System , Tachycardia, Ventricular/diagnosis , Tachycardia, Ventricular/surgery , Tachycardia, Ventricular/etiology , Heart Block
14.
J Interv Card Electrophysiol ; 66(8): 1939-1953, 2023 Nov.
Article in English | MEDLINE | ID: mdl-36929368

ABSTRACT

BACKGROUND: The current COVID-19 pandemic has led to many studies examining its arrhythmogenic effects. However, there are many other viruses that are capable of inducing arrhythmias that have not received as much attention. The objective of this study was to review common viruses and identify studies highlighting their arrhythmogenic effects. METHODS AND RESULTS: In this review, we examined 15 viruses and the literature regarding their arrhythmogenic effects. The common mechanisms of action appear to be direct invasion of myocytes leading to immune mediated damage, infection of vascular endothelium, and alteration of cardiac ion channels. CONCLUSIONS: This review highlights the growing evidence that supports the involvement of other viral infections in the development of arrhythmia. Physicians should be aware of these potentially life-threatening effects when caring for patients with these viruses, some of which are very common. Additional studies are required to better understand the complex mechanism and risk factors of cardiac arrhythmias in patients suffered from viral infections to determine whether the processes can be reversed or even prevented.


Subject(s)
Pandemics , Virus Diseases , Humans , Arrhythmias, Cardiac/etiology , Risk Factors , Virus Diseases/complications
16.
Heart Rhythm O2 ; 4(3): 171-179, 2023 Mar.
Article in English | MEDLINE | ID: mdl-36993911

ABSTRACT

Background: Prolongation of the PR interval has long been considered a benign condition, particularly in the setting of nonstructural heart disease. Objective: The purpose of this study was to investigate the effect of PR interval on various well-adjudicated cardiovascular outcomes using a large real-world population data of patients with implanted dual-chamber permanent pacemakers or implantable cardioverter-defibrillators. Methods: PR intervals were measured during remote transmissions in patients with implanted permanent pacemakers or implantable cardioverter-defibrillators. Study endpoints (time to the first occurrence of AF, heart failure hospitalization [HFH], or death) were obtained between January 2007 and June 2019 from the deidentified Optum de-identified Electronic Health Record dataset. Results: A total of 25,752 patients (age 69.3 ± 13.9 years; 58% male) were evaluated. The average intrinsic PR interval was 185 ± 55 ms. In the subset of 16,730 patients with available long-term device diagnostic data, a total of 2555 (15.3%) individuals developed AF during 2.59 ± 2.18 years of follow-up. The incidence of AF was significantly higher (up to 30%) in patients with a longer PR interval (ie, PR interval ≥270 ms; P < .05). Time-to-event survival analysis and multivariable analysis showed that PR interval ≥190 ms was significantly associated with higher incidence of AF, HFH, or HFH or death when compared with shorter PR intervals (P < .05 for all 3 parameters). Conclusion: In a large real-world population of patients with implanted devices, PR interval prolongation was significantly associated with increased incidence of AF, HFH, or death.

18.
Heart Rhythm ; 20(6): 863-871, 2023 06.
Article in English | MEDLINE | ID: mdl-36842610

ABSTRACT

BACKGROUND: Whether conduction system pacing (CSP) is an alternative option for cardiac resynchronization therapy (CRT) in patients with heart failure remains an area of active investigation. OBJECTIVE: The purpose of this study was to assess the echocardiographic and clinical outcomes of CSP compared to biventricular pacing (BiVP). METHODS: This multicenter retrospective study included patients who fulfilled CRT indications and received CSP. Patients with CSP were matched using propensity score matching and compared in a 1:1 ratio to patients who received BiVP. Echocardiographic and clinical outcomes were assessed. Response to CRT was defined as an absolute increase of ≥5% in left ventricular ejection fraction (LVEF) at 6 months post-CRT. RESULTS: A total of 238 patients were included. Mean age was 69.8 ± 12.5 years, and 66 (27.7%) were female. Sixty-nine patients (29%) had His-bundle pacing, 50 (21%) had left bundle branch area pacing, and 119 (50%) had BiVP. Mean follow-up duration in the CSP and BiVP groups was 269 ± 202 days and 304 ± 262 days, respectively (P = .293). The proportion of CRT responders was greater in the CSP group than in the BiVP group (74% vs 60%, respectively; P = .042). On Kaplan-Meier analysis, there was no statistically significant difference in the time to first heart failure hospitalization (log-rank P = .78) and overall survival (log-rank P = .68) between the CSP and BiVP groups. CONCLUSION: In patients with heart failure and reduced ejection fraction, CSP resulted in greater improvement in LVEF compared to BiVP. Large-scale randomized trials are needed to validate these outcomes and further investigate the different options available for CSP.


Subject(s)
Cardiac Resynchronization Therapy , Heart Failure , Humans , Female , Middle Aged , Aged , Aged, 80 and over , Male , Cardiac Resynchronization Therapy/methods , Stroke Volume , Retrospective Studies , Ventricular Function, Left/physiology , Treatment Outcome , Cardiac Conduction System Disease/therapy , Heart Failure/diagnosis , Heart Failure/therapy , Heart Failure/etiology , Electrocardiography/methods
19.
Annu Rev Med ; 74: 55-64, 2023 01 27.
Article in English | MEDLINE | ID: mdl-35914765

ABSTRACT

An estimated 10-15% of those infected with SARS-CoV-2 may have post-COVID-19 condition. Common lingering signs and symptoms include shortness of breath, fatigue, high heart rate, and memory and cognitive dysfunction even several months after infection, often impacting survivors' quality of life. The prevalence and duration of individual symptoms remain difficult to ascertain due to the lack of standardized research methods across various studies and limited patient follow-up in clinical studies. Nonetheless, data indicate post-COVID-19 condition may occur independent of acuity of initial infection, hospitalization status, age, or pre-existing comorbidities. Risk factors may include female sex and underlying respiratory or psychiatric disease. Supportive therapies to mitigate symptoms remain the mainstay of treatment. Reassuringly, most patients experience a reduction in symptoms by 1 year. The use of a universal case definition and shared research methods will allow for further clarity regarding the pervasiveness of this entity and its long-term health consequences.


Subject(s)
COVID-19 , Cognitive Dysfunction , Humans , Female , Quality of Life , SARS-CoV-2 , Cognitive Dysfunction/epidemiology , Cognitive Dysfunction/etiology , Dyspnea
20.
IEEE Trans Biomed Eng ; 70(3): 853-859, 2023 03.
Article in English | MEDLINE | ID: mdl-36049009

ABSTRACT

Conventional biventricular (BiV) pacing cardiac resynchronization therapy (CRT) is an established treatment for heart failure patients. Recently, multiple novel CRT delivering technologies such as His-Bundle pacing have been investigated as alternative pacing strategies for optimal treatment benefit. Electromechanical Wave Imaging (EWI), a high frame-rate echocardiography-based modality, is capable of visualizing the change from dyssynchronous activation to resynchronized BiV-paced ventricles in 3D. This proof-of-concept study introduces a new EWI-based dispersion metric to further characterize ventricular activation. Patients with His-Bundle device implantation (n = 4), left-bundle branch block (n = 10), right-ventricular (RV) pacing (n = 10), or BiV pacing (n = 15) were imaged, as well as four volunteers in normal sinus rhythm (NSR). EWI successfully mapped the ventricular activation resulting from His-Bundle pacing. Additionally, very similar activation patterns were obtained in the NSR subjects, confirming recovery of physiological activation with His pacing. The dispersion metric was the most sensitive EWI-based metric that identified His pacing as the most efficient treatment (lowest activation time spread), followed by BiV and RV pacing. More specifically, the dispersion metric significantly (p < 0.005) distinguished His pacing from the other two pacing schemes as well as LBBB. The initial findings presented herein indicate that EWI and its new dispersion metric may provide a useful resynchronization evaluation clinical tool in CRT patients under both novel His-Bundle pacing and more conventional BiV pacing strategies.


Subject(s)
Cardiac Resynchronization Therapy , Humans , Cardiac Resynchronization Therapy/methods , Bundle-Branch Block/diagnostic imaging , Bundle-Branch Block/therapy , Heart Ventricles/diagnostic imaging , Echocardiography , Arrhythmias, Cardiac
SELECTION OF CITATIONS
SEARCH DETAIL
...