Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Publication year range
1.
Sheng Wu Yi Xue Gong Cheng Xue Za Zhi ; 41(3): 439-446, 2024 Jun 25.
Article in Chinese | MEDLINE | ID: mdl-38932528

ABSTRACT

Electrical impedance tomography (EIT) is a non-radiation, non-invasive visual diagnostic technique. In order to improve the imaging resolution and the removing artifacts capability of the reconstruction algorithms for electrical impedance imaging in human-chest models, the HMANN algorithm was proposed using the Hadamard product to optimize multilayer artificial neural networks (MANN). The reconstructed images of the HMANN algorithm were compared with those of the generalized vector sampled pattern matching (GVSPM) algorithm, truncated singular value decomposition (TSVD) algorithm, backpropagation (BP) neural network algorithm, and traditional MANN algorithm. The simulation results showed that the correlation coefficient of the reconstructed images obtained by the HMANN algorithm was increased by 17.30% in the circular cross-section models compared with the MANN algorithm. It was increased by 13.98% in the lung cross-section models. In the lung cross-section models, some of the correlation coefficients obtained by the HMANN algorithm would decrease. Nevertheless, the HMANN algorithm retained the image information of the MANN algorithm in all models, and the HMANN algorithm had fewer artifacts in the reconstructed images. The distinguishability between the objects and the background was better compared with the traditional MANN algorithm. The algorithm could improve the correlation coefficient of the reconstructed images, and effectively remove the artifacts, which provides a new direction to effectively improve the quality of the reconstructed images for EIT.


Subject(s)
Algorithms , Electric Impedance , Image Processing, Computer-Assisted , Neural Networks, Computer , Thorax , Tomography , Humans , Tomography/methods , Thorax/diagnostic imaging , Image Processing, Computer-Assisted/methods , Lung/diagnostic imaging , Lung/physiology
2.
Sensors (Basel) ; 21(4)2021 Feb 21.
Article in English | MEDLINE | ID: mdl-33670072

ABSTRACT

A quantitative and rapid burn injury detection method has been proposed based on the electrical impedance spectroscopy (EIS) of blood with a seven-parameter equivalent circuit. The degree of burn injury is estimated from the electrical impedance characteristics of blood with different volume proportions of red blood cells (RBCs) and heated red blood cells (HRBCs). A quantitative relationship between the volume portion HHCT of HRBCs and the electrical impedance characteristics of blood has been demonstrated. A seven -parameter equivalent circuit is employed to quantify the relationship from the perspective of electricity. Additionally, the traditional Hanai equation has been modified to verify the experimental results. Results show that the imaginary part of impedance ZImt under the characteristic frequency (fc) has a linear relationship with HHCT which could be described by ZImt = -2.56HHCT - 2.01 with a correlation coefficient of 0.96. Moreover, the relationship between the plasma resistance Rp and HHCT is obtained as Rp = -7.2HHCT + 3.91 with a correlation coefficient of 0.96 from the seven -parameter equivalent circuit. This study shows the feasibility of EIS in the quantitative detection of burn injury by the quantitative parameters ZImt and Rp, which might be meaningful for the follow-up clinical treatment for burn injury.


Subject(s)
Burns , Dielectric Spectroscopy , Electric Impedance , Burns/diagnosis , Erythrocytes , Humans
3.
Biosens Bioelectron ; 141: 111437, 2019 Sep 15.
Article in English | MEDLINE | ID: mdl-31279177

ABSTRACT

Thrombus formation is quantitatively measured and evaluated by the electrical impedance spectroscopy method in this study, which confirms the possibility for the application of a promising non-invasive thrombus detection method. The impedance parameter Z*(t) of blood from the electrical impedance spectroscopy is utilized to elaborate the impedance performance of blood during thrombus formation process. Experimental results indicate that the impedance Z*(t) of blood has regular variations under the formation of thrombus, which could be divided into three stages. Modified Hanai equation is proposed to quantitatively expound the three stages of impedance Z*(t) variation. The amount of fibrin and thrombus clot is founded to be accounted for the impedance variation of blood, which confirms the feasibility and theoretical basis of the non-invasive and on-line thrombus bio-detection technology for patients with serious cardiovascular disease.


Subject(s)
Biosensing Techniques/instrumentation , Dielectric Spectroscopy/instrumentation , Fibrin/analysis , Thrombosis/blood , Animals , Blood Coagulation , Electric Impedance , Equipment Design , Humans , Swine , Thrombosis/diagnosis
4.
Sensors (Basel) ; 19(5)2019 Mar 04.
Article in English | MEDLINE | ID: mdl-30836669

ABSTRACT

The aggregation of red blood cells (RBCs) in normal blood (non-coagulation) has been quantitatively measured by blood pulsatile flow based on multiple-frequency electrical impedance spectroscopy. The relaxation frequencies fc under static and flowing conditions of blood pulsatile flow are utilized to evaluate the RBC aggregation quantitatively with the consideration of blood flow factors (RBC orientation, deformation, thickness of electrical double layer (EDL)). Both porcine blood and bovine blood are investigated in experiments, for the reason that porcine blood easily forms RBC aggregates, while bovine blood does not. The results show that the relaxation frequencies fc of porcine blood and bovine blood present opposite performance, which indicates that the proposed relaxation frequency fc is efficient to measure RBCs aggregation. Furthermore, the modified Hanai equation is proposed to quantitatively calculate the influence of RBCs aggregation on relaxation frequency fc. The study confirms the feasibility of a high speed, on-line RBC aggregation sensing method in extracorporeal circulation systems.


Subject(s)
Erythrocytes/physiology , Animals , Cattle , Cell Aggregation/physiology , Dielectric Spectroscopy , Electric Impedance , Erythrocyte Aggregation/physiology , Humans , Swine
SELECTION OF CITATIONS
SEARCH DETAIL
...