Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Int J Prosthodont ; 37(7): 55-62, 2024 Feb 21.
Article in English | MEDLINE | ID: mdl-38489221

ABSTRACT

PURPOSE: To evaluate the wear resistance of a printed interim resin manufactured with different printing and postpolymerization parameters. MATERIALS AND METHODS: Overall, 130 rectangular resin specimens (15 × 10 × 10 mm) were 3D-printed. Among the specimens, 60 were printed with different printing orientations (0, 45, and 90 degrees) and layer thicknesses (50 and 100 µm) to create six groups to investigate the effects of the printing parameters (n = 10 per group). The remaining 70 specimens were used to evaluate the effects of postpolymerization; for this, seven groups were created as follows (n = 10 per group): nonpostpolymerized; postpolymerized for 5, 15, and 30 minutes with an ultraviolet light-emitting diode (LED) device; and postpolymerized for 5, 15, and 30 minutes with an ultraviolet light bulb device. After masticatory simulation, the wear volume loss was calculated with 3D metrology software. One-way and two-way ANOVA were used for intergroup comparisons (α = .05). RESULTS: The group printed with a build angle of 45 degrees showed lower wear volume loss than the 0- and 90-degree groups (P < .01). The wear volume loss in the ultraviolet LED group was significantly greater than that in the ultraviolet light bulb group (P = .04). No significant difference was observed in the wear volume loss of the printed resin with respect to the layer thickness and polymerization time (P > .05). However, the non-postpolymerized group showed significantly greater wear volume loss than the other groups (P < .001). CONCLUSIONS: The printed resin showed greater wear resistance when it was printed at a build angle of 45 degrees and postpolymerized with an ultraviolet light bulb device.


Subject(s)
Printing, Three-Dimensional , Software , Materials Testing , Computer Simulation
2.
J Dent ; 138: 104738, 2023 11.
Article in English | MEDLINE | ID: mdl-37806382

ABSTRACT

OBJECTIVES: Evidence on the reliability of digital techniques for wear volume assessment using three-dimensional (3D) scan datasets is scarce. This study evaluated the reliability of a repeated-scan superimposition technique and two single-scan techniques in assessing wear volume loss on flat surfaces of 3D-printed resin specimens. METHODS: Cuboid-shaped (15×10×10 mm) resin specimens were 3D-printed (n = 14) and scanned before and after 200,000 cycles of masticatory simulation. For the repeated-scan superimposition technique, digital 3D models of specimens before and after masticatory simulation were superimposed, and the volume loss was determined. The first single-scan technique utilized a computer-aided design freeware program, while the second one employed a 3D-metrology software program. In the freeware program, the worn area of 3D objects was edited directly to obtain a flat surface. In the 3D-metrology software program, the worn area was deleted first and then filled to the flat surface. The volume differences before and after editing were calculated in each software program. Agreement between the three measurement techniques was determined through intraclass correlation coefficients (ICCs). One-way analysis of variance was performed to compare the wear volume loss assessed by the three techniques (α = 0.05). RESULTS: High inter-technique reliability was observed between the three assessment techniques (ICC = 0.998, p < .001). On pair-wise comparisons of two of the three techniques, all pairs showed high consistency (ICC ≥ 0.999, p < .001). No significant difference was found in the wear volume loss assessed using the three techniques (p = .996). CONCLUSIONS: Digital repeated-scan superimposition and two single-scan techniques demonstrated high reliability in assessing wear volume loss on flat surfaces. CLINICAL SIGNIFICANCE: The repeated-scan superimposition technique can be effectively utilized to assess wear volume loss of anatomically shaped specimens and flat surfaces. This study indicates that the single-scan techniques may serve as a suitable alternative to the repeated-scan superimposition technique when evaluating wear volume loss of flat surfaces.


Subject(s)
Computer-Aided Design , Software , Reproducibility of Results , Computer Simulation , Imaging, Three-Dimensional/methods
SELECTION OF CITATIONS
SEARCH DETAIL
...