1.
Clin Biomech (Bristol, Avon) ; 28(9-10): 994-9, 2013.
Article in English | MEDLINE | ID: mdl-24161521

ABSTRACT

BACKGROUND: Transtibial amputees encounter stairs and steps during their daily activities. The excessive pressure between residual limb/socket may reduce the walking capability of transtibial prosthetic users during ascent and descent on stairs. The purposes of the research were to evaluate the interface pressure between Dermo (shuttle lock) and Seal-In X5 (prosthetic valve) interface systems during stair ascent and descent, and to determine their satisfaction effects on users. METHODS: Ten amputees with unilateral transtibial amputation participated in the study. Interface pressure was recorded with F-socket transducer (9811E) during stair ascent and descent at self-selected speed. Each participant filled in a questionnaire about satisfaction and problems encountered with the use of the two interface systems. FINDINGS: The resultant mean peak pressure (kPa) was significantly lower for the Dermo interface system compared to that of the Seal-In X5 interface system at the anterior, posterior and medial regions during stair ascent (63.14 vs. 80.14, 63.14 vs. 90.44, 49.21 vs. 66.04, respectively) and descent (67.11 vs. 80.41, 64.12 vs. 88.24, 47.33 vs. 65.11, respectively). Significant statistical difference existed between the two interface systems in terms of satisfaction and problems encountered (P<0.05). INTERPRETATION: The Dermo interface system caused less pressure within the prosthetic socket compared to the Seal-In X5 interface system during stair negotiation. The qualitative survey also showed that the prosthesis users experienced fewer problems and increased satisfaction with the Dermo interface system.


Subject(s)
Amputation Stumps/physiopathology , Amputation, Surgical/rehabilitation , Amputees/psychology , Artificial Limbs/psychology , Gait/physiology , Patient Satisfaction , Adult , Aged , Female , Humans , Male , Middle Aged , Pressure , Prosthesis Design , Young Adult
2.
Clin Biomech (Bristol, Avon) ; 27(9): 943-8, 2012 Nov.
Article in English | MEDLINE | ID: mdl-22795863

ABSTRACT

BACKGROUND: The interface pressure between the residual limb and prosthetic socket has a significant effect on an amputee's satisfaction and comfort. Liners provide a comfortable interface by adding a soft cushion between the residual limb and the socket. The Dermo and the Seal-In X5 liner are two new interface systems and, due to their relative infancy, very little are known about their effect on patient satisfaction. The aim of this study was to compare the interface pressure with these two liners and their effect on patient satisfaction. METHODS: Nine unilateral transtibial amputees participated in the study. Two prostheses were fabricated for each amputee, one with the Seal-In liner and one with the Dermo liner. Interface pressure was measured at the anterior, posterior, medial and lateral regions during walking on the level ground. Each subject filled in a Prosthetic Evaluation Questionnaire (PEQ) regarding the satisfaction with the two liners. Findings The mean peak pressures with the Seal-In liner was 34.0% higher at the anterior, 24.0% higher at the posterior and 7.0% higher at the medial regions of the socket (P=0.008, P=0.046, P=0.025) than it was with the Dermo Liner. There were no significant differences in the mean peak pressures between the two liners at the lateral regions. In addition, significant difference was found between the two liners both for satisfaction and problems (P<0.05). Interpretation There was less interface pressure between the socket and the residual limb with the Dermo liner. The results indicated that the Dermo liner provides more comfort in the socket than the Seal-In liner.


Subject(s)
Amputation Stumps/physiopathology , Knee Joint/physiopathology , Knee Joint/surgery , Orthotic Devices , Tibia/physiopathology , Walking , Equipment Design , Equipment Failure Analysis , Female , Humans , Male , Middle Aged , Patient Satisfaction , Pressure , Tibia/surgery , Treatment Outcome