Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 16 de 16
Filter
Add more filters











Publication year range
1.
Sensors (Basel) ; 24(8)2024 Apr 09.
Article in English | MEDLINE | ID: mdl-38676004

ABSTRACT

To monitor the position and profile of therapeutic carbon beams in real-time, in this paper, we proposed a system called HiBeam-T. The HiBeam-T is a time projection chamber (TPC) with forty Topmetal-II- CMOS pixel sensors as its readout. Each Topmetal-II- has 72 × 72 pixels with the size of 83 µm × 83 µm. The detector consists of the charge drift region and the charge collection area. The readout electronics comprise three Readout Control Modules and one Clock Synchronization Module. This Hibeam-T has a sensitive area of 20 × 20 cm and can acquire the center of the incident beams. The test with a continuous 80.55 MeV/u 12C6+ beam shows that the measurement resolution to the beam center could reach 6.45 µm for unsaturated beam projections.

2.
Small ; 20(31): e2400045, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38453678

ABSTRACT

Emerging photoelectrochemical (PEC) photodetectors (PDs) have notable advantages over conventional PDs and have attracted extensive attention. However, harsh liquid environments, such as those with high corrosivity and attenuation, substantially restrict their widespread application. Moreover, most PEC PDs are constructed by assembling numerous nanostructures on current collector substrates, which inevitably contain abundant interfaces and defects, thus greatly weakening the properties of PDs. To address these challenges, a high-performance pH-universal PEC ultraviolet (UV) PD based on a whole single-crystal integrated self-supporting 4H-SiC nanopore array photoelectrode is constructed, which is fabricated using a two-step anodic oxidation approach. The PD exhibits excellent photodetection behavior, with high responsivity (218.77 mA W-1), detectivity (6.64 × 1013 Jones), external quantum efficiency (72.47%), and rapid rise/decay times (17/48 ms) under 375 nm light illumination with a low intensity of 0.15 mW cm-2 and a bias voltage of 0.6 V, which is fall in the state-of-the-art of the wide-bandgap semiconductor-based PDs reported thus far. Furthermore, the SiC PEC PD exhibits excellent photoresponse and long-term operational stability in pH-universal liquid environments. The improved photodetection performance of the SiC PEC PD is primarily attributed to the synergistic effect of the nanopore array structure, integrated self-supporting configuration, and single-crystal structure of the whole photoelectrode.

3.
ACS Appl Mater Interfaces ; 15(19): 23457-23469, 2023 May 17.
Article in English | MEDLINE | ID: mdl-37148254

ABSTRACT

Currently, the photodetectors (PDs) assembled by vertically aligned nanostructured arrays have attracted intensive interest owing to their unique virtues of low light reflectivity and rapid charge transport. However, in terms of the inherent limitations caused by numerous interfaces often existed within the assembled arrays, the photogenerated carriers cannot be effectively separated, thus weakening the performance of target PDs. Aiming at resolving this critical point, a high-performance ultraviolet (UV) PD with a single-crystal integrated self-supporting 4H-SiC nanohole arrays is constructed, which are prepared via the anode oxidation approach. As a result, the PD delivers an excellent performance with a high switching ratio (∼250), remarkable detectivity (6 × 1010 Jones), fast response (0.5 s/0.88 s), and excellent stability under 375 nm light illumination with a bias voltage of 5 V. Moreover, it has a high responsivity (824 mA/W), superior to those of most reported ones based on 4H-SiC. The overall high performance of the PDs could be mainly attributed to the synergistic effect of the SiC nanohole arrays' geometry, a whole single-crystal integrated self-supporting film without interfaces, established reliable Schottky contact, and incorporated N dopants.

4.
Mol Genet Genomics ; 298(4): 791-801, 2023 Jul.
Article in English | MEDLINE | ID: mdl-37086279

ABSTRACT

Osteoarthritis (OA) is a common and crippling joint disease characterized by cartilage degeneration, subchondral bone sclerosis, and synovitis. The main clinical manifestations of OA are chronic joint pain and impaired mobility, which seriously affect patient's quality of life. Circular RNAs (circRNAs) are noncoding RNAs that are widely discovered in eukaryotic cells. Unlike standard linear RNAs, circRNAs form a covalently closed continuous loop structure without a 5' or 3' polarity. Various experiments in recent years have confirmed that numerous circRNAs appear to be differentially expressed in OA cartilage and synovium. And they are closely associated with various pathological progressions in OA, such as extracellular matrix degradation, chondrocyte apoptosis, and inflammation. In this review, we briefly described the biogenesis, characterization, and functions of circRNAs. And we focused on the relationships between circRNAs and OA progression. At last, we further discussed the prospects of clinical applications of circRNAs in OA, with the expectation to provide feasible directions for OA diagnosis and treatment.


Subject(s)
Cartilage, Articular , MicroRNAs , Osteoarthritis , Humans , RNA, Circular/genetics , RNA, Circular/metabolism , MicroRNAs/metabolism , Quality of Life , Cartilage, Articular/metabolism , Cartilage, Articular/pathology , Osteoarthritis/therapy , Osteoarthritis/drug therapy
5.
Ann Gastroenterol Surg ; 7(1): 7-9, 2023 Jan.
Article in English | MEDLINE | ID: mdl-36643357

ABSTRACT

A multimodality treatment conference with experts from across East Asia was held to establish a consensus for conversion therapy. An agreement was reached that conversion therapy was defined as surgery or chemoradiotherapy (CRT) aiming at cure after initial treatment for tumors that were initially unresectable due to adjacent organ invasion or distant metastasis.

6.
Article in English | MEDLINE | ID: mdl-36066449

ABSTRACT

OBJECTIVES: Drainless thoracoscopic surgery, defined by omitting chest drain after surgery, has been demonstrated to be feasible in selected patients for pulmonary resection. However, drainless procedure for the treatment of primary spontaneous pneumothorax has raised concerns for its safety and thus has been less often reported. We aimed to share our preliminary experience regarding how to select patients with spontaneous pneumothorax for this procedure. METHODS: A retrospective study recruiting 303 consecutive patients with the diagnosis of spontaneous pneumothorax undergoing thoracoscopic surgery in our centre from August 2016 to June 2020 was done. After careful selection, the chest drain was omitted in selected patients who underwent non-intubated uniportal thoracoscopic surgery. Patients' clinical characteristics and perioperative outcomes were analysed. RESULTS: A total of 34 patients underwent drainless thoracoscopic surgery for the treatment of spontaneous pneumothorax. Pleural adhesion was noted in 9 patients during surgery, and all of them (100%) developed residual pneumothorax, among which intercostal drainage was required in 2 (22.2%) patients and ipsilateral pneumothorax recurred 3 years after surgery in 1 (11.1%) patient. Among the remaining 25 without pleural adhesion, 17 (68.0%) developed minor residual pneumothorax (P = 0.006), which all resolved spontaneously within 1-2 weeks, with no complications or recurrence during postoperative follow-up for at least 2 years. CONCLUSIONS: Drainless thoracoscopic surgery for the treatment of primary spontaneous pneumothorax is feasible but can be risky without careful patient selection. In our experience, the drainless procedure should be avoided in patients with identifiable pleural adhesion noted during surgery.


Subject(s)
Pneumothorax , Chest Tubes/adverse effects , Humans , Pneumothorax/diagnostic imaging , Pneumothorax/etiology , Pneumothorax/surgery , Recurrence , Retrospective Studies , Thoracic Surgery, Video-Assisted/adverse effects , Thoracic Surgery, Video-Assisted/methods
7.
J Chromatogr A ; 1681: 463459, 2022 Oct 11.
Article in English | MEDLINE | ID: mdl-36108351

ABSTRACT

In this work, a magnetic MIL-101(γ-Fe2O3)/MWCNTs composite derived from iron-based metal-organic frameworks (MIL-101(Fe)) with multi-walled carbon nanotubes (MWCNTs) was successfully synthesized by low-temperature calcination process. The composite was used as adsorbent of magnetic solid-phase extraction (MSPE) for enhanced and rapid enrichment of trace polycyclic aromatic hydrocarbons (PAHs) based on its strong π-π stacking interactions, hydrophobic and cationic-π stacking interactions. The pseudo-second-order kinetic model and Langmuir isotherm model could be applied to better describe the adsorption process. The maximum adsorption capacity for PAHs reached 93.9 mg g-1. In addition, the conditions of MSPE process were optimized by orthogonal array design (OAD). A MSPE-HPLC-UV method was established for the sensitive detection of PAHs in real water samples and exhibited wide linear range (0.05-1000 µg L-1), low detection limits (0.02-0.41 µg L-1) and high enrichment factors (44-169) for PAHs. The relative standard deviations (RSD) ranged from 0.8 to 4.0% and 1.2-7.2% for single batch and batch-to-batch, respectively, and the spiked recoveries at two levels of 10 and 50 µg L-1 ranged from 79.6 to 112% with RSD of less than 5.81%. The unique MWCNTs in situ anchor MIL-101(γ-Fe2O3) composite with an outstanding PAHs adsorption performance provides a new opportunity and promising application in removal of toxic pollutants.


Subject(s)
Metal-Organic Frameworks , Nanotubes, Carbon , Polycyclic Aromatic Hydrocarbons , Water Pollutants, Chemical , Adsorption , Chromatography, High Pressure Liquid , Iron , Limit of Detection , Magnetic Phenomena , Nanotubes, Carbon/chemistry , Polycyclic Aromatic Hydrocarbons/analysis , Solid Phase Extraction/methods , Water , Water Pollutants, Chemical/analysis
8.
Zhongguo Gu Shang ; 34(7): 679-83, 2021 Jul 25.
Article in Chinese | MEDLINE | ID: mdl-34318648

ABSTRACT

OBJECTIVE: To compare the clinical efficacy of distal radius T-plate combined with suture anchor and distal clavicle anatomical locking plate combined with suture anchor in the treatment of Neer Ⅱb distal clavicle fracture. METHODS: From June 2014 to June 2018, 42 patients with Neer Ⅱb distal clavicle fractures were retrospectively analyzed. According to different surgical methods, they were divided into the observation group (T-shaped plate combined with suture anchor) and the control group (anatomical locking plate combined with suture anchor). There were 22 patients in the observation group and 20 patients in the control group. In the observation group, there were 13 males and 9 females, aged from 22 to 70 (45.78± 14.44) years old, 12 cases on the left side and 10 cases on the right side, 8 cases of traffic accident injury and 14 cases of fall. In the control group, there were 12 males and 8 females, aged from 24 to 66 (44.17±15.58) years, 13 cases on the left side and 7 cases on the right side, 6 cases of traffic accident injuryand 14 cases of fall. The operation time, intraoperative blood loss and fracture healing time were compared between the two groups, and Constant Murley score was used to evaluate shoulder joint function. RESULTS: The patients in both groups were followed up for 18 to 24 (20.96±2.02) months. The incisions of both groups were healed at stageⅠ. The fracture ends of both groups were bony healed at the last follow up. There was no significant difference in operation time, intraoperative blood loss and fracture healing time between two groups (P>0.05);there was no significant difference in shoulder joint function between two groups at 3 months after operation (P>0.05). CONCLUSION: The two methods can obtain satisfactory results in the treatment of Neer Ⅱb distal clavicle fractures, especially suitable for patients with comminuted distal clavicle fractures or osteoporosis; the clinical effect of the treatment of NeerⅡb distal clavicle fractures with T type distal radius plate combined with suture anchor is satisfactory, which provides another feasible treatment scheme for clinic.


Subject(s)
Clavicle , Fractures, Bone , Aged , Aged, 80 and over , Bone Plates , Case-Control Studies , Clavicle/surgery , Female , Fracture Fixation, Internal , Fractures, Bone/surgery , Humans , Male , Middle Aged , Retrospective Studies , Suture Anchors , Treatment Outcome
9.
Bioengineered ; 12(1): 1976-1985, 2021 12.
Article in English | MEDLINE | ID: mdl-34034633

ABSTRACT

Acute kidney injury (AKI) was a frequent complication following hip fracture surgery, but recent studies reported inconsistent findings. Our study was aimed at clarifying the prevalence and risk factors of AKI after hip fracture surgery. Pubmed, Embase, and Web of Science were systematically searched from the inception to March 2020 to identify observational studies investigating the prevalence and risk factors of AKI in patients undergoing hip fracture surgery. Pooled prevalence and odds ratios (ORs) with 95% confidence intervals (CIs) were estimated using a random-effects model. Publication bias was evaluated with a funnel plot and statistical test. All the statistical analyses were performed using Stata version 12.0. A total of 11 studies with 16,421 patients was included in the current meta-analysis. The pooled prevalence of AKI in patients undergoing hip fracture surgery was 17% (95%CI, 14%-21%) with substantial heterogeneity (I2 = 95%). Postoperative serum albumin (OR 1.80; 95%CI, 1.38-2.36) was a significant predictor for AKI. Age (OR 1.01; 95%CI, 0.95-1.07) and ACE inhibitors (OR 1.38; 95%CI, 0.92-2.07) were associated with increased the risk of AKI, but the results were not statistically significant. No significant publication bias was identified through statistical tests (Egger's test, p = 0.258 and Begg's test, p = 0.087). In conclusion, our findings indicated that the pooled AKI following hip fracture surgery was approximately 17%. Postoperative serum albumin was a potential significant risk factor for AKI.


Subject(s)
Acute Kidney Injury , Hip Fractures , Orthopedic Procedures , Acute Kidney Injury/epidemiology , Acute Kidney Injury/etiology , Aged , Aged, 80 and over , Female , Hip Fractures/epidemiology , Hip Fractures/surgery , Humans , Male , Middle Aged , Orthopedic Procedures/adverse effects , Orthopedic Procedures/statistics & numerical data , Prevalence , Risk Factors
10.
Cogn Sci ; 44(12): e12921, 2020 12.
Article in English | MEDLINE | ID: mdl-33314282

ABSTRACT

Source code is a form of human communication, albeit one where the information shared between the programmers reading and writing the code is constrained by the requirement that the code executes correctly. Programming languages are more syntactically constrained than natural languages, but they are also very expressive, allowing a great many different ways to express even very simple computations. Still, code written by developers is highly predictable, and many programming tools have taken advantage of this phenomenon, relying on language model surprisal as a guiding mechanism. While surprisal has been validated as a measure of cognitive load in natural language, its relation to human cognitive processes in code is still poorly understood. In this paper, we explore the relationship between surprisal and programmer preference at a small granularity-do programmers prefer more predictable expressions in code? Using meaning-preserving transformations, we produce equivalent alternatives to developer-written code expressions and run a corpus study on Java and Python projects. In general, language models rate the code expressions developers choose to write as more predictable than these transformed alternatives. Then, we perform two human subject studies asking participants to choose between two equivalent snippets of Java code with different surprisal scores (one original and transformed). We find that programmers do prefer more predictable variants, and that stronger language models like the transformer align more often and more consistently with these preferences.


Subject(s)
Comprehension , Language , Probability , Programming Languages , Cognition , Humans , Reading , Writing
11.
Oncol Lett ; 20(3): 2606-2612, 2020 Sep.
Article in English | MEDLINE | ID: mdl-32782578

ABSTRACT

Osteosarcoma is a malignant tumor that occurs in children and adolescents. Although treatments for osteosarcoma have improved, the likelihood of survival remains low for most patients with metastasis and recurrence. Elucidating the mechanism underlying the development of osteosarcoma and chemotherapy resistance will be important to improve diagnosis and treatment. Long non-coding RNAs (lncRNAs), which are longer than 200 nucleotides in length and do not encode for proteins, have been shown to play a regulatory role in the occurrence and development of osteosarcoma, and are expected to serve as biomarkers and molecular targets. This review discusses the progress in the study of the role of lncRNAs in osteosarcoma, and highlights the recent developments in this field.

12.
Materials (Basel) ; 12(23)2019 Nov 28.
Article in English | MEDLINE | ID: mdl-31795285

ABSTRACT

In this study, magnetic visible light driven photocatalysts (bismuth ferrite, Bi2Fe4O9, BFO and Co-doped bismuth ferrite, Co-BFO) were successfully prepared by the facile hydrothermal method. The catalyst was used in the application of heterogeneous persulfate (PS) system under visible LED light irradiation for the degradation of levofloxacin (LFX), proving to be an excellent photocatalyst when evaluated by various characterization methods. The effect of Co-doping in the BFO structure was investigated that the decrease of band gap width and the generated photoelectrons and holes would effectively reduce the recombination of photogenerated electron-hole pairs, leading to the enhancement photocatalytic activity. The results demonstrated that Co-BFO catalyst had a high photodegradation efficiency over a wide pH range of 3.0-9.0 and the Co-BFO-2 composite displayed the optimal catalytic performance. It was found that the degradation rate of LFX by Co-BFO-2 catalyst was 3.52 times higher than that of pure BFO catalyst under visible light condition. The free radical trapping experiments and EPR tests demonstrated that superoxide, photogenerated holes and sulfate radicals were the main active species in the photocatalytic degradation of LFX. And a possible photocatalytic degradation mechanism of LFX was proposed in the Vis/Co-BFO/PS process. These findings provided new insight of the mechanism of heterogeneous activation of persulfate by Co-BFO under visible light irradiation.

13.
J Med Case Rep ; 12(1): 75, 2018 Mar 19.
Article in English | MEDLINE | ID: mdl-29551093

ABSTRACT

BACKGROUND: Pulmonary arteriovenous malformations are rare vascular abnormalities that permit direct communication between the pulmonary artery and vein. During pregnancy, pulmonary arteriovenous malformation carries an increased risk of enlargement and rupture, which could lead to life-threatening hemothorax. This is the first case reporting successful thoracoscopic surgery for a pregnant woman with pulmonary arteriovenous malformation rupture-related hemothorax. CASE PRESENTATION: We present a case of a 32-year-old pregnant Asian woman (31 weeks' gestation) whose pulmonary arteriovenous malformation ruptured, leading to right-sided spontaneous tension hemothorax. First, an emergency cesarean section for hypovolemic shock-related fetal distress was performed to save the baby. Immediately afterwards, video-assisted thoracic surgery with the single-incision approach allowed us to successfully obtain hemostasis and eradication of abnormal vasculature by conducting wedge resection of the pulmonary arteriovenous malformation. CONCLUSIONS: Emergency thoracoscopic surgery for a pregnant woman with pulmonary arteriovenous malformation rupture-related hemothorax is safe and feasible. In contrast to transcatheter arterial embolization, video-assisted thoracic surgery could simultaneously achieve hemostasis for prevention of mortality, eradication of abnormal vasculature, and removal of massive thrombi.


Subject(s)
Arteriovenous Malformations/complications , Hemothorax/etiology , Hemothorax/surgery , Pregnancy Complications/etiology , Pregnancy Complications/surgery , Thoracic Surgery, Video-Assisted/methods , Adult , Cesarean Section , Female , Humans , Pregnancy , Rupture, Spontaneous , Treatment Outcome
14.
Respirol Case Rep ; 6(1): e00278, 2018 01.
Article in English | MEDLINE | ID: mdl-29075497

ABSTRACT

Tracheobronchial injuries are rare but life-threatening conditions in patients with blunt thoracic trauma. The diagnosis and management of such injury may often be delayed due to other concomitant severe injuries. No reported case of a robotic-assisted bronchial reconstruction has ever been performed for a traumatic bronchial injury. A 23-year-old male suffered from traumatic left main bronchial (LMB) rupture with an initial presentation of pneumothorax and pneumomediastinum that eventually progressed to left main bronchus fibrosis and total obstruction, which led to left lung atelectasis and consolidation. Minimally invasive robotic-assisted sleeve surgery, 33 days after the initial trauma, successfully reconstructed the left main bronchus with satisfactory morphological and functional results. Recognition of a bronchial injury and precise localization of the lesion is mandated to ensure a prompt and adequate salvage surgical procedure in order to help patients recover from this critical condition.

15.
Clin Chim Acta ; 411(5-6): 386-90, 2010 Mar.
Article in English | MEDLINE | ID: mdl-20005218

ABSTRACT

BACKGROUND: Mice with defects in the Klotho gene exhibit multiple aging phenotypes including arteriosclerosis. We hypothesised that the G-395A polymorphism in the promoter region of the human Klotho gene may contribute to the prevalence of Essential Hypertension (EH). METHODS: We investigate whether the G-395A polymorphism of Klotho is associated with EH in a population consisting of 215 patients with EH and 220 non-hypertensive subjects. We also tested whether a G/A substitution at the G-395A site affected the transcription level in vitro through the dual-luciferase reporter assay. RESULTS: Differences in the genotype distributions of the G-395A polymorphism between the EH and non-hypertension groups are statistically significant (P=0.032). There are differential effects of age, gender and smoking status on the association of the G-395A polymorphism with EH; the G-395A polymorphism is significantly associated with EH in subjects over 60years old, in females and in nonsmokers. A multiple logistic regression analysis indicated that the odds ratio for EH in the -395A allele carriers as compared with the control group was 0.593 (P=0.024) after adjusting for current traditional risk factors. The dual-luciferase reporter assay revealed that the -395A carrier of a 498-bp DNA fragment (containing the G-395A site) upstream of the Klotho gene has higher relative luciferase activity than the -395G carrier. CONCLUSIONS: The G-395A polymorphism of the human Klotho gene is associated with EH and may be a potential regulatory site.


Subject(s)
Asian People/genetics , Ethnicity/genetics , Glucuronidase/genetics , Hypertension/genetics , Polymorphism, Single Nucleotide/genetics , Promoter Regions, Genetic/genetics , China , DNA Mutational Analysis , Female , Genetic Predisposition to Disease/genetics , Humans , Klotho Proteins , Male , Middle Aged , Polymerase Chain Reaction
SELECTION OF CITATIONS
SEARCH DETAIL