Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 13 de 13
Filter
1.
BMC Musculoskelet Disord ; 25(1): 530, 2024 Jul 11.
Article in English | MEDLINE | ID: mdl-38987728

ABSTRACT

PURPOSE: Few studies have focused on the risk factors leading to postoperative blood transfusion after open reduction and internal fixation (ORIF) of proximal humeral fractures (PHFs) in the elderly. Therefore, we designed this study to explore potential risk factors of blood transfusion after ORIF for PHFs. We have also established a nomogram model to integrate and quantify our research results and give feedback. METHODS: In this study, we retrospectively analyzed the clinical data of elderly PHF patients undergoing ORIF from January 2020 to December 2021. We have established a multivariate regression model and nomograph. The prediction performance and consistency of the model were evaluated by the consistency coefficient and calibration curve, respectively. RESULTS: 162 patients met our inclusion criteria and were included in the final study. The following factors are related to the increased risk of transfusion after ORIF: time to surgery, fibrinogen levels, intraoperative blood loss, and surgical duration. CONCLUSIONS: Our patient-specific transfusion risk calculator uses a robust multivariable model to predict transfusion risk.The resulting nomogram can be used as a screening tool to identify patients with high transfusion risk and provide necessary interventions for these patients (such as preoperative red blood cell mobilization, intraoperative autologous blood transfusion, etc.).


Subject(s)
Blood Transfusion , Fracture Fixation, Internal , Nomograms , Open Fracture Reduction , Shoulder Fractures , Humans , Aged , Female , Male , Fracture Fixation, Internal/adverse effects , Fracture Fixation, Internal/methods , Retrospective Studies , Shoulder Fractures/surgery , Aged, 80 and over , Cross-Sectional Studies , Open Fracture Reduction/adverse effects , Open Fracture Reduction/methods , Risk Factors , Risk Assessment , Blood Loss, Surgical/prevention & control
2.
Injury ; 52(10): 2947-2951, 2021 Oct.
Article in English | MEDLINE | ID: mdl-34399985

ABSTRACT

PURPOSE: The purpose of our study was to determine the risk factors for reduction loss in patients with proximal humeral fractures after locking plate fixation and establish a nomogram prediction model. METHODS: We retrospectively analyzed the clinical data of proximal humeral fractures patients who had been surgically treated for locking plate in our institution from January 2016 to December 2018. Perioperative information was obtained through the electronic medial record system, univariate and multivariate analyzes were performed to determine the risk factors of reduction loss, and a nomogram model was constructed to predict the risk of reduction loss. The predictive performance and consistency of the model were evaluated by the consistency coefficient (C-index) and the calibration curve, respectively. RESULTS: 115 patients were finally enrolled in our study. Multivariate analysis results showed that age, fracture classification, medial comminution, and calcar screw status were independent risk factors for reduction loss. The accuracy of the contour map for predicting transfusion risk was 0.944. CONCLUSION: We found a correlation between reduction loss and age, fracture classification, medial comminution, and calcar screw status after locking plate fixation for proximal humeral fractures patients. Our nomogram is helpful for clinicians to identify high-risk patients, early intervention and reduce the incidence of reduction loss.


Subject(s)
Humeral Fractures , Shoulder Fractures , Bone Plates , Fracture Fixation, Internal/adverse effects , Humans , Humeral Fractures/surgery , Nomograms , Retrospective Studies , Shoulder Fractures/diagnostic imaging , Shoulder Fractures/surgery
3.
BMC Musculoskelet Disord ; 21(1): 406, 2020 Jun 27.
Article in English | MEDLINE | ID: mdl-32593311

ABSTRACT

BACKGROUND: With the rapid aging of the population, the incidence of proximal humeral fracture (PHF) has increased. However, the optimal method for open reduction and internal fixation (ORIF) remains controversial. METHODS: We performed a retrospective analysis of patients with PHF who underwent locking plate internal fixation at our institution from January 2016 to December 2018. Patients were divided into two groups based on the surgical approach used: an expanded deltoid-split approach group (ORIF group) and minimally invasive deltoid-split approach group (minimally invasive percutaneous plate osteosynthesis, [MIPPO] group). The groups were compared in terms of demographic and perioperative characteristics, and clinical outcomes. RESULTS: A total of 115 cases of PHF were included in our study, of which 64 cases were treated using the minimally invasive deltoid-split approach and 51 using the extended deltoid-split approach. Fluoroscopy was performed significantly less frequently in the ORIF group and the surgical duration was shorter. However, the postoperative visual analogue scale (VAS) pain score and duration of postoperative hospital stay were significantly higher compared to the MIPPO group. Moreover, secondary loss was significantly less extensive in the ORIF group compared to the MIPPO group, while there was no significant group difference in fracture healing time, Constant shoulder score, or complications at the last follow-up visit. CONCLUSIONS: The clinical outcomes associated with both the minimally invasive and extended deltoid-split approaches were satisfactory. The data presented here suggest that the extended deltoid-split approach was superior to the minimally invasive deltoid-split approach in terms of operational time, fluoroscopy, and secondary loss of reduction, while the minimally invasive approach was superior in terms of postoperative pain and hospital stay. Accordingly, neither procedure can be considered definitively superior; the optimal surgical procedure for PHF can only be determined after full consideration of the situation and requirements of the individual patient.


Subject(s)
Bone Plates , Deltoid Muscle/surgery , Fracture Fixation, Internal/methods , Minimally Invasive Surgical Procedures/methods , Shoulder Fractures/surgery , Aged , Case-Control Studies , Deltoid Muscle/diagnostic imaging , Female , Fracture Fixation, Internal/instrumentation , Fracture Healing , Humans , Male , Middle Aged , Minimally Invasive Surgical Procedures/instrumentation , Operative Time , Shoulder Fractures/diagnostic imaging , Treatment Outcome
4.
Injury ; 51(6): 1382-1386, 2020 Jun.
Article in English | MEDLINE | ID: mdl-32327232

ABSTRACT

PURPOSE: There were few reports in the literature about the hidden blood loss (HBL) after intramedullary nail (IMN) fixation for extra-articular tibial fractures. Our purpose was to evaluate the amount of hidden blood loss after intramedullary nail fixation for extra-articular tibial fractures, meanwhile, identified the influential factors causing HBL. METHODS: From January 2015 to December 2017, 122 consecutive extra-articular tibial fracture patients fixed with IMN and 96 met all inclusion criteria for the chosen analysis. Preoperative hematocrit (Hct) levels on admission and postoperative Hct levels on the third day after surgery to calculate the amount of HBL. RESULTS: The mean HBL was 473.29 ± 102.75 ml after IMN fixation of extra-articular tibial fractures, the multiple regression analysis showed gender, surgical duration, and the diameter of the medullary cavity at the narrowest part of the tibia had an independent influence on HBL. CONCLUSIONS: A significant amount of postoperative HBL has occurred after IMN fixation of extra-articular tibial fractures. Surgeons should be aware that more HBL can be developed in patients who have male sex, small medullary cavity, and long-time surgical duration. HBL deserves attention to ensure patients' safety in the perioperative period of IMN fixation for extra-articular tibial fractures.


Subject(s)
Fracture Fixation, Intramedullary/adverse effects , Postoperative Hemorrhage/blood , Tibial Fractures/surgery , Adult , Female , Hemoglobins/analysis , Humans , Linear Models , Male , Middle Aged , Multivariate Analysis , Perioperative Period , Retrospective Studies
5.
Med Sci Monit ; 26: e920255, 2020 Feb 19.
Article in English | MEDLINE | ID: mdl-32074099

ABSTRACT

BACKGROUND The aim of this study was to determine the risk factors and develop a nomogram for blood transfusions after hemiarthroplasty (HA) in patients with femoral neck fractures (FNFs). MATERIAL AND METHODS We performed a retrospective study including consecutive elderly FNF patients treated by HA between January 2015 and December 2017. Perioperative information was obtained retrospectively, uni- and multivariate regression analyses were conducted to determine risk factors for blood transfusion, and a nomogram model was constructed to predict the risk of blood transfusion. The predictive performance and consistency of the model were evaluated by the consistency coefficient (C-index) and the calibration curve, respectively. RESULTS Of 178 patients, 151 were finally enrolled in the study and 21 received blood transfusion. Binary logistic regression analysis showed the low preoperative hemoglobin (Hb), longer time to surgery, general anesthesia, longer surgery duration, and higher intraoperative blood loss (IBL) were risk factors for blood transfusion. The accuracy of the contour map for predicting transfusion risk was 0.940. CONCLUSIONS We found a correlation between blood transfusion requirement and low preoperative Hb, longer time to surgery, general anesthesia, longer surgery duration, and higher IBL, and we then developed a nomogram. Our nomogram model can be used to evaluate the transfusion risk for FNF patients after HA, and provides better guidance for clinicians to intervene perioperatively, so as to reduce the incidence of blood transfusion.


Subject(s)
Blood Transfusion , Femoral Neck Fractures/surgery , Hemiarthroplasty , Nomograms , Aged , Aged, 80 and over , Calibration , Female , Humans , Logistic Models , Male , Risk Factors
6.
J Orthop Surg Res ; 14(1): 102, 2019 Apr 11.
Article in English | MEDLINE | ID: mdl-30975173

ABSTRACT

BACKGROUND: With the development of indirect three-dimensional (3D) printing technology, it is possible to customise individual scaffolds to be used in bone transplantation and regeneration. In addition, materials previously limited to the 3D printing (3DP) process due to their own characteristics can also be used well in indirect 3DP. In this study, customised ß-TCP/chitosan scaffolds with the shape of rabbit radial head were produced by indirect 3D printing technology. METHODS: Swelling ability, porosity, mechanical characterisation, and degradation rate analysis were performed, and in vitro studies were also implemented to evaluate the proliferation and osteogenic differentiation of bone marrow mesenchymal stem cells (MSCs) on the scaffolds. CCK8 cell proliferation assay kit and alkaline phosphatase (ALP) staining solution were used to study cell proliferation and early ALP content at the scaffold surface. Moreover, the osteogenic differentiation of MSCs on scaffolds was also evaluated through the scanning electron microscopy analysis. RESULTS: ß-TCP/chitosan scaffold has good performance and degradation rate, and in vitro cell experiments also confirm that the scaffold has adequate cytocompatibility and bioactivity. CONCLUSION: This study provides a promising new strategy for the design of customised scaffolds for the repair of complex damaged tissues.


Subject(s)
Calcium Phosphates/chemistry , Chitosan/chemistry , Printing, Three-Dimensional , Radius/chemistry , Tissue Engineering/methods , Tissue Scaffolds/chemistry , Animals , Calcium Phosphates/administration & dosage , Cell Differentiation/physiology , Cells, Cultured , Chitosan/administration & dosage , Mesenchymal Stem Cells/chemistry , Mesenchymal Stem Cells/physiology , Printing, Three-Dimensional/trends , Rabbits , Radius/diagnostic imaging , Radius/physiology
7.
BMJ Open ; 9(1): e024110, 2019 01 28.
Article in English | MEDLINE | ID: mdl-30696677

ABSTRACT

INTRODUCTION: The optimal treatment for burst fractures of the thoracolumbar spine is controversial. The addition of screws in the fractured segment has been shown to improve construct stiffness, but can aggravate the trauma to the fractured vertebra. Therefore, optimised placement of two pedicle screws at the fracture level is required for the treatment of thoracolumbar burst fractures. This randomised controlled study is the first to examine the efficacy of diverse orders of pedicle screw placement and will provide recommendations for the treatment of patients with thoracolumbar burst fractures. METHODS AND ANALYSIS: A randomised controlled trial with blinding of patients and the statistician, but not the clinicians and researchers, will be conducted. A total of 70 patients with single AO type A3 or A4 thoracolumbar fractures who are candidates for application of short-segment pedicle screws at the fractured vertebral level will be allocated randomly to the distraction-screw and screw-distraction groups at a ratio of 1:1. The primary clinical outcome measures will be the percentage loss of vertebral body height, screw depth in the injured vertebrae and kyphosis (Cobb angle). Secondary clinical outcome measures will be complications, Visual Analogue Scale scores for back and leg pain, neurological function, operation time, intraoperative blood loss, Japanese Orthopaedic Association score and Oswestry Disability Index. These parameters will be evaluated preoperatively, intraoperatively, on postoperative day 3, and at 1, 3, 6, 12 and 24 months postoperatively. ETHICS AND DISSEMINATION: The Institutional Review Board of the Second Affiliated Hospital and Yuying Children's Hospital of Wenzhou Medical University have reviewed and approved this study (batch: LCKY2018-05). The results will be presented in peer-reviewed journals and at an international spine-related meeting after completion of the study. TRIAL REGISTRATION NUMBER: NCT03384368; Pre-results.


Subject(s)
Fracture Fixation, Internal/methods , Fractures, Compression/surgery , Lumbar Vertebrae/surgery , Pedicle Screws , Spinal Fractures/surgery , Thoracic Vertebrae/surgery , Humans , Lumbar Vertebrae/injuries , Single-Blind Method , Thoracic Vertebrae/injuries , Treatment Outcome
8.
J Invest Surg ; 32(8): 716-722, 2019 Dec.
Article in English | MEDLINE | ID: mdl-29641267

ABSTRACT

Background: There is a large amount of hidden blood loss (HBL) after total hip arthroplasty (THA), but the effective and safe methods to reduce HBL are still controversial. Methods: Sixty-nine consecutive patients who underwent THA in our hospital from January 2015 to December 2015 were analyzed retrospectively. The patients were divided into two groups, Group A (THA without oxidized regenerated cellulose) and Group B (THA with oxidized regenerated cellulose). Demographics, perioperative laboratory values, intraoperative data, blood loss, transfusion rate, transfusion reactions, and surgical complications were collected and analyzed. Results: A total of 37 (54%) patients used oxidized regenerated cellulose (ORC) in operation. The total blood loss (TBL), postoperative blood loss (PBL), hemoglobin (Hb) loss, and hidden blood loss (HBL) in group B were significantly lower than in group A. Conclusions: The use of ORC to fill the bone surface and soft tissue gap before incision closure can effectively reduce HBL and may be a potential treatment for blood prevention after THA.


Subject(s)
Arthroplasty, Replacement, Hip/adverse effects , Cellulose, Oxidized/administration & dosage , Hemostasis, Surgical/methods , Hemostatics/administration & dosage , Postoperative Hemorrhage/prevention & control , Administration, Topical , Aged , Arthroplasty, Replacement, Hip/methods , Blood Loss, Surgical/prevention & control , Blood Loss, Surgical/statistics & numerical data , Blood Transfusion/statistics & numerical data , Female , Hemoglobins/analysis , Humans , Male , Middle Aged , Postoperative Hemorrhage/blood , Postoperative Hemorrhage/diagnosis , Postoperative Hemorrhage/etiology , Retrospective Studies , Treatment Outcome
9.
Injury ; 50(2): 546-550, 2019 Feb.
Article in English | MEDLINE | ID: mdl-30580930

ABSTRACT

PURPOSE: To explore the hidden blood loss (HBL) in treatment of extra-articular tibial fractures with plate and intramedullary nail fixation. METHODS: We conducted a retrospective study including 209 consecutive patients treated by plate (Group LCP) or intramedullary nail fixation (Group IMN) for extra-articular tibial fractures between January 2015 to December 2017. Demographics, intraoperative data, perioperative laboratory values, transfusion rate, and early complications were collected and analyzed. RESULTS: Of 209 patients, 96 patients fixed with IMN and 113 fixed with LCP. The average HBL was 272.71 ± 57.88 ml in Group LCP and 507.66 ± 109.81 ml in Group IMN, and there was statistical difference in the HBL between two groups (p < 0.001). The Hb and Hct loss, surgical duration, and postoperative number of anemic patients in Group IMN were significantly higher than in Group LCP (p < 0.001), and IMN fixation has a significantly higher rate of transfusion (p = 0.027), whereas patients in group IMN has significantly less VBL (p < 0.001), shorter postoperative hospital stay (p < 0.001), and less superficial infection (p = 0.014). CONCLUSIONS: There was a significant amount of hidden blood loss after reamed intramedullary nail fixation for extra-articular tibial fractures, which was much higher than expected. In view of the morbidity of acute anaemia and transfusion, we suggest that for patients who suffer from extra-articular tibial fractures with multiple injuries, or those with low haemoglobin preoperatively, plates might be more suitable than nail fixation.


Subject(s)
Blood Loss, Surgical/statistics & numerical data , Fracture Fixation, Intramedullary/methods , Fracture Healing/physiology , Tibial Fractures/surgery , Adult , Blood Loss, Surgical/physiopathology , Bone Plates , Female , Fracture Fixation, Intramedullary/adverse effects , Humans , Male , Middle Aged , Perioperative Period , Retrospective Studies , Tibial Fractures/physiopathology , Treatment Outcome
10.
BMC Musculoskelet Disord ; 19(1): 420, 2018 Nov 30.
Article in English | MEDLINE | ID: mdl-30497479

ABSTRACT

BACKGROUND: Although the proximal humeral fractures (PHFs) treated with locking plate have been well applied, there are few studies concerning on the serial HSA changes after locking plate placement. The purpose of this retrospective study was to explored the clinical significance of serial HSA changes after surgery. METHODS: We retrospectively analyzed the clinical data of 122 patients between January 2012 to December 2016 in our hospital. The serial change of the HSA and Neer's score of 122 patients were recorded and analyzed. Then, we evaluated the HSA changes affected functional recovery in conjunction with medial support (MS). Moreover, multivariable linear regression analysis was performed to identify any potential confounding factors that may influence functional recovery. RESULTS: Of 146 patients, 122 (50 males and 72 females) patients were finally enrolled in our study. Our preliminary data suggested that the most decrease of HSA occurred in the period of 1 to 3 months (p < 0.001) postoperatively, and functional recovery was significantly related with the change of HSA (R2 = 0.647, p < 0.001). The presence of MS plays an important role in maintaining postoperative HSA and restoring function. Moreover, Neer type 4 fracture, the difference between the postoperative HSA (on the injured side) and that of the uninjured side (the ΔHSA), and the HSA change to the end of follow-up were all significantly associated with functional recovery. CONCLUSIONS: Serial HSA changes were evident in PHF patients in whom locking plates had been inserted; it is essential to maintain reduction for 1-3 months postoperatively. MS is important in this context and surgeons must maximally restore MS. Furthermore, the functional outcome tended to improve when the HSA of the injured side was restored to a value close to that of the uninjured side.


Subject(s)
Fracture Fixation, Internal/adverse effects , Humerus/anatomy & histology , Postoperative Complications/diagnostic imaging , Recovery of Function , Shoulder Fractures/surgery , Adult , Aged , Aged, 80 and over , Bone Plates , Female , Follow-Up Studies , Fracture Fixation, Internal/instrumentation , Fracture Fixation, Internal/methods , Humans , Humerus/diagnostic imaging , Humerus/surgery , Male , Middle Aged , Postoperative Complications/etiology , Postoperative Complications/physiopathology , Retrospective Studies , Shoulder Joint/physiopathology , Treatment Outcome
11.
Clin Interv Aging ; 13: 1639-1645, 2018.
Article in English | MEDLINE | ID: mdl-30237699

ABSTRACT

PURPOSE: Several authors have reported the degree of total blood loss (TBL) following hemiarthroplasty for displaced femoral neck fracture; however, the research specifically investigating on hidden blood loss (HBL) after hip hemiarthroplasty is still lacking. The purpose of this study is to evaluate the HBL in patients who underwent hip hemiarthroplasty for displaced femoral neck fractures and to analyze its risk factors. PATIENTS AND METHODS: From January 2015 to December 2016, 212 patients (57 males and 155 females) with displaced femoral neck fracture undergoing hip hemiarthroplasty were included in this study. The demographic and relevant clinical information of the patients were collected. According to the Gross's formula, each patient's height, weight, and preoperative and postoperative hematocrit were recorded and used for calculating the total perioperative blood loss and HBL. Risk factors were further analyzed by multivariate linear regression. RESULTS: The HBL was 525±217 mL, with 61.0%±13.6% in the total perioperative blood loss (859±289 mL), and the perioperative hemoglobin (Hb) loss was 23.8±7.4 g/L. Multivariate linear regression analysis revealed that HBL was positively associated with higher American Society of Anesthesiologists (ASA) classification (regression coefficient=62.169, 95% CI=15.616-108.722; P=0.009), perioperative gastrointestinal bleeding/ulcer (regression coefficient=155.589, 95% CI=38.095-273.083; P=0.010), and transfusion (regression coefficient=192.118, 95% CI=135.578-248.659; P<0.001). Compared with females, males had a risk of increased HBL (regression coefficient=87.414, 95% CI=28.547-146.280; P=0.004), and general anesthesia had an increased HBL compared with spinal anesthesia (regression coefficient=68.920, 95% CI=11.707-126.134; P=0.018). CONCLUSION: HBL should not be ignored in patients who underwent hip hemiarthroplasty for displaced femoral neck fractures in the perioperative period, because it is a significant portion of TBL. Female patients, patients with higher ASA classification and perioperative gastrointestinal bleeding/ulcer, patients who were administered general anesthesia, or patients who underwent transfusion had a greater amount of HBL after hip hemiarthroplasty was performed. Having a correct understanding of HBL may help surgeons improve clinical assessment capabilities and ensure patients' safety.


Subject(s)
Blood Loss, Surgical/statistics & numerical data , Femoral Neck Fractures/surgery , Fracture Dislocation/surgery , Hemiarthroplasty/adverse effects , Aged , Aged, 80 and over , Cross-Sectional Studies , Female , Humans , Male , Risk Factors
12.
BMJ Open ; 8(8): e021667, 2018 08 08.
Article in English | MEDLINE | ID: mdl-30093519

ABSTRACT

INTRODUCTION: Arthroscopic-assisted balloon tibioplasty is an emerging technology that has shown advantages in recovering depression of the articular surface. However, studies evaluating clinical outcomes between arthroscopic-assisted balloon tibioplasty and traditional open reduction internal fixation (ORIF) are sparse. This is the first randomised study to compare arthroscopic-assisted balloon tibioplasty with ORIF, and will provide guidance for treating patients with Schatzker types II, III and IV with depression of the medial tibial plateau only. METHODS AND ANALYSIS: A blinded randomised controlled trial will be conducted and a total of 80 participants will be randomly divided into either the arthroscopic-assisted balloon tibioplasty group or the ORIF group, at a ratio of 1:1. The primary clinical outcome measures are the knee functional scores, Rasmussen radiological evaluation scores and the quality of reduction based on postoperative CT scan. Secondary clinical outcome measures are intraoperative blood loss, surgical duration, visual analogue scale score after surgery, hospital duration after surgery, complications and 36-Item Short-Form Health Survey score. ETHICS AND DISSEMINATION: This study has been reviewed and approved by the Institutional Review Board of the Second Affiliated Hospital of Wenzhou Medical University (batch: 2017-12). The results will be presented in peer-reviewed journals after completion of the study. TRIAL REGISTRATION NUMBER: NCT03327337, Pre-results.


Subject(s)
Arthroscopy/methods , Fracture Fixation, Internal/methods , Open Fracture Reduction/methods , Tibial Fractures/surgery , Adolescent , Adult , Aged , Aged, 80 and over , Clinical Protocols , Female , Humans , Male , Middle Aged , Treatment Outcome , Young Adult
13.
Biomed Res Int ; 2017: 6781070, 2017.
Article in English | MEDLINE | ID: mdl-28503572

ABSTRACT

Purpose. The purpose of this study is to evaluate the learning curve of performing surgery with the InterTan intramedullary nail in treating femoral intertrochanteric fractures, to provide valuable information and experience for surgeons who decide to learn a new procedure. Methods. We retrospectively analyzed data from 53 patients who underwent surgery using an InterTan intramedullary nail at our hospital between July 2012 and September 2015. The negative exponential curve-fit regression analysis was used to evaluate the learning curve. According to 90% learning milestone, patients were divided into two group, and the outcomes were compared. Results. The mean operative time was 69.28 (95% CI 64.57 to 74.00) minutes; with the accumulation of surgical experience, the operation time was gradually decreased. 90% of the potential improvement was expected after 18 cases. In terms of operative time, intraoperative blood loss, hospital stay, and Harris hip score significant differences were found between two groups (p = 0.009, p = 0.000, p = 0.030, and p = 0.002, resp.). Partial weight bearing time, fracture union time, tip apex distance, and the number of blood transfusions and complications were similar between two groups (p > 0.5). Conclusion. This study demonstrated that the learning curve of performing surgery with the InterTan intramedullary nail is acceptable and 90% of the expert's proficiency level is achieved at around 18 cases.


Subject(s)
Femoral Fractures/surgery , Fracture Fixation, Internal/methods , Fracture Fixation, Intramedullary/methods , Hip Fractures/surgery , Aged , Aged, 80 and over , Bone Nails , Female , Femoral Fractures/physiopathology , Hip Fractures/physiopathology , Humans , Learning Curve , Male , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...