Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Ultrasound Med Biol ; 47(1): 114-124, 2021 01.
Article in English | MEDLINE | ID: mdl-33239154

ABSTRACT

The aim of the work described here was to evaluate the diagnostic performance of ultrasound thyroid computer-aided diagnosis (CAD) software. This multicenter prospective study included 494 patients (565 thyroid nodules) who underwent surgery or biopsy after ultrasonography at four hospitals from January 2019 to September 2019. The diagnostic performance metrics of different readers were calculated and compared with the pathologic results. The sensitivity of CAD was outstanding and was equivalent to that of a senior radiologist (90.51% vs. 88.47%, p > 0.05). The area under the curve of CAD was equivalent to that of a junior radiologist (0.748 vs. 0.739, p > 0.05). However, the specificity was only 49.63%, which was lower than those of the three radiologists (75.56%, 85.93% and 90.37% for the junior, intermediate and senior radiologists, respectively). The diagnostic performance of the junior radiologist was significantly improved with the aid of CAD (junior + CAD). The sensitivity and area under the curve of junior + CAD were improved from 72.20% to 89.93% and from 0.739 to 0.816, respectively (both p values <0.05), and the positive predictive value, negative predictive value and κ coefficient improved from 76.3% to 78.6%, 82.0% to 86.8% and 0.394 to 0.511, respectively. Though specificity slightly decreased from 75.56% to 73.33%, the difference was not statistically significant (p > 0.05). In general, the clinical application value of CAD is promising, and its instrumental value for junior radiologists is significant.


Subject(s)
Clinical Competence , Diagnosis, Computer-Assisted , Radiology , Software , Thyroid Neoplasms/diagnostic imaging , Adult , Female , Humans , Male , Middle Aged , Prospective Studies , Ultrasonography
2.
Scand J Gastroenterol ; 52(4): 403-408, 2017 Apr.
Article in English | MEDLINE | ID: mdl-28079407

ABSTRACT

OBJECTIVE: The objective of this study is to evaluate the gastric emptying in patients with systemic lupus erythematosus (SLE) with gastrointestinal involvement using three-dimensional (3D) ultrasonography. METHODS: The gastric emptying times at 25% (T1), 50% (T2), and 75% (T3) of SLE patients with gastrointestinal involvement (n = 40) and healthy controls (n = 80) were evaluated and compared. In addition, the correlations among the gastric wall thickness, SLE disease activity index (SLEDAI), and upper gastrointestinal symptoms were calculated. RESULTS: The gastric wall thickness was correlated with the SLEDAI (r = 0.928, p < 0.001) and the upper gastrointestinal symptom index (r = 0.848, p < 0.001). The emptying times T1, T2, and T3 of the SLE patients were 17.08 ± 2.65 min (mean ± standard deviation), 39.85 ± 6.54 min, and 83.58 ± 7.12 min, respectively. For healthy controls, they were 19.65 ± 5.39 min, 41.08 ± 7.51 min, and 70.34 ± 8.03 min. The T1 of the SLE patients was shorter (p < 0.01), while the T3 was longer (p < 0.001). Moreover, T3 in the SLE group had the best correlation with the upper gastrointestinal symptom index (r = 0.553, p < 0.001). T1 in the SLE group was anti-correlated with early satiety (r = -0.366, p < 0.05). CONCLUSIONS: Combining the emptying times T1 and T3, as well as the gastric wall thickness, the SLEDAI and the upper gastrointestinal symptoms index can provide accurate clinical diagnosis of SLE with gastric involvement.


Subject(s)
Gastric Emptying , Lupus Erythematosus, Systemic/physiopathology , Stomach/diagnostic imaging , Stomach/pathology , Ultrasonography , Adult , Case-Control Studies , China , Female , Humans , Imaging, Three-Dimensional , Male , Middle Aged , Severity of Illness Index
3.
Br J Radiol ; 89(1068): 20160366, 2016 Dec.
Article in English | MEDLINE | ID: mdl-27759430

ABSTRACT

OBJECTIVE: Improvement in regional blood flow has been shown to ameliorate diabetic gastroparesis. We compared the gastric blood supply in patients with diabetes with gastroparesis with that in healthy subjects, by using contrast-enhanced ultrasound (CEUS). METHODS: 30 healthy subjects and 40 patients with diabetic gastroparesis were enrolled. The CEUS parameters of greater curvatures of the antrum (GCOA) and lesser curvatures of the antrum (LCOA), including peak intensity (PI) and the area under the curve (AUC), were compared between the two groups. RESULTS: Intraclass correlation coefficient (ICC) for PI in healthy subjects measured on CEUS were 0.831-0.857 and 0.803-0.823, respectively. Intra-ICC and inter-ICC values for AUC were 0.805-0.823 and 0.813-0.815, respectively. In both groups, no significant difference was observed in PI and AUC values of GCOA and LCOA (p > 0.05). The PI and AUC of GCOA and LCOA in the diabetes group were less than those in the normal group (p < 0.05). CONCLUSION: CEUS can assess stomach wall vascularity with a high reproducibility. Microcirculation in the antrum of patients with diabetic gastroparesis is poorer than that of normal group, which is consistent with the mechanisms of diabetic neuropathy. CEUS can be used for evaluation of microvascular perfusion in patients with stomach wall disease. Advances in knowledge: This was the first study to use CEUS for assessment of blood supply of the gastric wall and to compare microvascular perfusion between healthy individuals and patients with diabetes with gastroparesis.


Subject(s)
Contrast Media , Diabetes Complications/diagnostic imaging , Gastroparesis/diagnostic imaging , Stomach/blood supply , Stomach/diagnostic imaging , Ultrasonography , Adult , Area Under Curve , Female , Humans , Image Enhancement/methods , Male , Middle Aged , Regional Blood Flow , Reproducibility of Results
4.
Ultrasound Med Biol ; 40(9): 1998-2003, 2014 Sep.
Article in English | MEDLINE | ID: mdl-25023116

ABSTRACT

In order to explore the accuracy of ultrasonic whole stomach cylinder measurement (UWSCM) in the evaluation of gastric emptying, we measured the gastric emptying times (ET) at 25% (T1), 50% (T2) and 75% (T3) of healthy subjects and patients with diabetic gastropathy by UWSCM and scintigraphy. The ET of patients were compared with their clinical symptom scores. We found that the ET measured by UWSCM showed no significant difference with scintigraphy (p > 0.05). The correlation between them was good, and the correlation coefficient of T3 reached 0.744 (p < 0.05). All emptying times in the diabetic patients were longer than those in the healthy subjects (p < 0.05). The T3 in the diabetic group measured by UWSCM had the best correlation with the symptom index (r = 0.469, p < 0.05). We conclude that ET measured by UWSCM is accurate and T3 combining the symptoms index provides an accurate clinical basis for gastropathy.


Subject(s)
Diabetes Mellitus/physiopathology , Gastric Emptying/physiology , Stomach/diagnostic imaging , Adult , Female , Humans , Male , Middle Aged , Radionuclide Imaging , Reproducibility of Results , Time Factors , Ultrasonography
SELECTION OF CITATIONS
SEARCH DETAIL
...