Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 23
Filter
Add more filters










Publication year range
1.
Sensors (Basel) ; 24(10)2024 May 16.
Article in English | MEDLINE | ID: mdl-38794009

ABSTRACT

In this study, we propose a method for optimizing the design of CMUT sensors using genetic algorithms. Existing CMUT sensors face frequency response and sensitivity limitations, necessitating optimization to enhance their sensing performance. Traditional optimization methods are often intricate and time-consuming and may fail to yield the optimal solution. Genetic algorithms, which simulate the biological evolution process, offer advantages in global optimization and efficiency, making them widely utilized in the optimization design of Microelectromechanical Systems (MEMS) devices. Based on the theoretical framework and finite element model of CMUT sensors, we propose a CMUT array element optimization design method based on genetic algorithms. The optimization and validation results demonstrate that we have successfully designed a broadband CMUT array element consisting of four microelements with a 1-2 MHz frequency range. Compared with a randomly arranged array element, the optimized array shows a 63.9% increase in bandwidth and a 7.5% increase in average sensitivity within the passband. Moreover, the sensitivity variance within the passband is reduced by 50.2%. Our proposed method effectively optimizes the design of high sensitivity CMUT sensors with the desired bandwidth, thereby offering significant reference value for the optimization design of CMUT sensors.

2.
Micromachines (Basel) ; 15(2)2024 Jan 30.
Article in English | MEDLINE | ID: mdl-38398937

ABSTRACT

This paper presents the design and development of a high-resolution 3D ultrasound imaging system based on a 1 × 256 piezoelectric ring array, achieving an accuracy of 0.1 mm in both ascending and descending modes. The system achieves an imaging spatial resolution of approximately 0.78 mm. A 256 × 32 cylindrical sensor array and a digital phantom of breast tissue were constructed using the k-Wave toolbox. The signal is acquired layer by layer using 3D acoustic time-domain simulation, resulting in the collection of data from each of the 32 layers. The 1 × 256 ring array moves on a vertical trajectory from the chest wall to the nipple at a constant speed. A data set was collected at intervals of 1.5 mm, resulting in a total of 32 data sets. Surface rendering and volume rendering algorithms were used to reconstruct 3D ultrasound images from the volume data obtained via simulation so that the smallest simulated reconstructed lesion had a diameter of 0.3 mm. The reconstructed three-dimensional image derived from the experimental data exhibits the contour of the breast model along with its internal mass. Reconstructable dimensions can be achieved up to approximately 0.78 mm. The feasibility of applying the system to 3D breast ultrasound imaging has been demonstrated, demonstrating its attributes of resolution, precision, and exceptional efficiency.

3.
Biosensors (Basel) ; 13(1)2023 Jan 12.
Article in English | MEDLINE | ID: mdl-36671966

ABSTRACT

With advances in new materials and technologies, there has been increasing research focused on flexible sensors. However, in most flexible pressure sensors made using new materials, it is challenging to achieve high detection sensitivity across a wide pressure range. Although traditional silicon-based sensors have good performance, they are not formable and, because of their rigidity and brittleness, they are not suitable for fitting with soft human skin, which limits their application in wearable devices to collect various signals. Silicon nanomembranes are ultra-thin, flexible materials with excellent piezoresistive properties, and they can be applied in various fields, such as in soft robots and flexible devices. In this study, we developed a flexible pressure sensor based on the use of silicon nanomembranes (with a thickness of only 340 nm) as piezoresistive units, which were transferred onto a flexible polydimethylsiloxane (PDMS) substrate. The flexible pressure sensor operated normally in the range of 0-200 kPa, and the sensitivity of the sensor reached 0.0185 kPa-1 in the low-pressure range of 0-5 kPa. In the high-pressure range of 5-200 kPa, the sensitivity of the sensor was maintained at 0.0023 kPa-1. The proposed sensor exhibited a fast response and excellent long-term stability and could recognize human movements, such as the bending of fingers and wrist joints, while maintaining a stable output. Thus, the developed flexible pressure sensor has promising applications in body monitoring and wearable devices.


Subject(s)
Robotics , Silicon , Humans , Movement , Skin , Technology
4.
Micromachines (Basel) ; 13(12)2022 Dec 08.
Article in English | MEDLINE | ID: mdl-36557472

ABSTRACT

In light of a need for low-frequency, high sensitivity and broadband cardiac murmur signal detection, the present work puts forward an integrated MEMS-based heart sound sensor with a hollow concave ciliary micro-structure. The advantages of a hollow MEMS structure, in contrast to planar ciliated micro-structures, are that it reduces the ciliated mass and enhances the operating bandwidth. Meanwhile, the area of acoustic-wave reception is enlarged by the concave architecture, thereby enhancing the sensitivity at low frequencies. By rationally designing the acoustic encapsulation, the loss of heart acoustic distortion and weak cardiac murmurs is reduced. As demonstrated by experimentation, the proposed hollow MEMS structure cardiac sound sensor has a sensitivity of up to -206.9 dB at 200 Hz, showing 6.5 dB and 170 Hz increases in the sensitivity and operating bandwidth, respectively, in contrast to the planar ciliated MEMS sensor. The SNR of the sensor is 26.471 dB, showing good detectability for cardiac sounds.

5.
Micromachines (Basel) ; 13(11)2022 Oct 26.
Article in English | MEDLINE | ID: mdl-36363848

ABSTRACT

The study of impedance matching between a transducer and its working medium is an important part of acoustic transducer design. The traditional quarter wavelength matching (Q-matching) scheme is not suitable for broadband capacitive micromachined ultrasonic transducers. To mitigate this issue, a 0-3 composite broadband matching layer based on polydimethylsiloxane (PDMS) substrate/TiO2 particles is designed to achieve electrical insulation and efficient acoustic energy transfer of underwater capacitive micromachined ultrasonic transducer (CMUT) devices. In this work, the coherent potential approximation model is used to analyze the properties of 0-3 composite materials. Samples are prepared for performance testing to determine the proportion of TiO2 particles that enable the 0-3 composite materials to have the same longitudinal acoustic impedance as water. The CMUT device is packaged by a spin coating and pouring process, and its performance tests are carried out. The experimental results show that the central frequency of the transducer remains at 1.74 MHz, the -6 dB fractional bandwidth increases from 97.3% to 100.3%, the 3 dB directional main beam width increases from 8.3° to 10.3°, the side lobes decrease significantly, and the device has good reception sensitivity. These values imply that the 0-3 composite material has good matching performance, and this matching scheme has the advantages of high efficiency and wide bandwidth. This broadband matching method endows CMUTs with great advantages in underwater detection systems, and it facilitates underwater ultrasonic imaging of CMUT.

6.
Materials (Basel) ; 15(19)2022 Oct 10.
Article in English | MEDLINE | ID: mdl-36234373

ABSTRACT

(1) Mud pulser carbide rotors, as a core component of ground communication in crude oil exploration, are often subjected to mud erosion and acid corrosion, resulting in pitting pits on the surface, which affects the accuracy. The purpose of this study was to investigate the acid corrosion and erosion behavior of cemented carbide materials and provide a reference for the wider application of cemented carbide materials in the petrochemical industry. (2) Experimental samples of tungsten-cobalt carbide were sintered at a low pressure by powder metallurgy. The petrochemical application environment was simulated by accelerated salt spray corrosion and solid slurry erosion with the aid of acidic copper, and the experimental phenomena were analyzed by SEM (scanning electron microscope), EDS (Energy Dispersive Spectroscopy), and XRD (X-ray diffraction). (3) The experimental results show that the coercivity of the pitted cobalt-cemented tungsten carbide prepared in this study was 17.89 KA/m, and the magnetic saturation strength was 14.42 G·cm3/g. The corrosion rate was the fastest during the acidic copper acceleration experiments from 4 h to 16 h, and the corrosion products of WCo3 and Co3O4 were generated on the corrosion surface. The maximum erosion rate of 0.00104 in the erosion experiment corresponds to a corrosion sample with a corrosion time of 36 h. (4) Therefore, the coercive magnetic force and magnetic saturation strength could be derived from the prepared carbide hard phase grains and carbon content in the appropriate range. The corrosion product in the corrosion process slowed the corrosion rate, and a large amount of cobalt and a small amount of tungsten was lost by oxidation during the corrosion process. The corrosion time had the greatest effect on the erosion performance of the carbide, and the long corrosion time led to surface sparseness, which reduced the erosion resistance.

7.
Biomed Microdevices ; 24(3): 27, 2022 08 12.
Article in English | MEDLINE | ID: mdl-35953589

ABSTRACT

To acquire high-quality electrocardiogram (ECG) signals, traditional Ag/AgCl wet electrodes used together with conductive gel can effectively reduce electrode-skin interface impedance (EII) in a short term. However, their weaknesses of poor flexibility and instability can no longer meet the long-term monitoring requirements of intelligent wearable devices. Owing to the flexible dry electrode without conductive gel, it is a good choice to solve the critical problem on drying-out of conductive gel. Therefore, we develop a flexible microneedle array electrode (FMAE) based on polydimethylsiloxane (PDMS) substrate, which obtains reliable bioelectrical signals by way of penetrating into the stratum corneum (SC) of the skin. The fabrication process, including silicon mold, twice PDMS shape-transferring and encapsulation, has advantages of low cost, repeatable production and good biocompatibility. Afterwards, by comparing the performance with different electrodes, impedance test results indicate that the impedance of FMAE are smaller and more stable, and ECG tests in long term and at resting/jogging states also verify that FMAE can obtain durable, stable and reliable signals. In conclusion, FMAE is promising in long-term ECG monitoring.


Subject(s)
Electrocardiography , Wearable Electronic Devices , Dimethylpolysiloxanes , Electric Impedance , Electrodes
8.
Biosensors (Basel) ; 12(7)2022 Jul 18.
Article in English | MEDLINE | ID: mdl-35884337

ABSTRACT

The biomedical acoustic signal plays an important role in clinical non-invasive diagnosis. In view of the deficiencies in early diagnosis of cardiovascular diseases, acoustic properties of S1 and S2 heart sounds are utilized. In this paper, we propose an integrated concave cilium MEMS heart sound sensor. The concave structure enlarges the area for receiving sound waves to improve the low-frequency sensitivity, and realizes the low-frequency and high-sensitivity characteristics of an MEMS heart sound sensor by adopting a reasonable acoustic package design, reducing the loss of heart sound distortion and faint heart murmurs, and improving the auscultation effect. Finally, experimental results show that the integrated concave ciliated MEMS heart sound sensor's sensitivity reaches -180.6 dB@500 Hz, as compared with the traditional bionic ciliated MEMS heart sound sensor; the sensitivity is 8.9 dB higher. The sensor has a signal-to-noise ratio of 27.05 dB, and has good heart sound detection ability, improving the accuracy of clinical detection methods.


Subject(s)
Heart Sounds , Micro-Electrical-Mechanical Systems , Cilia , Heart , Signal-To-Noise Ratio
9.
Materials (Basel) ; 15(15)2022 Jul 25.
Article in English | MEDLINE | ID: mdl-35897585

ABSTRACT

An AlCrSiWN coating was prepared on a cemented carbide substrate by the arc ion plating technology. The optimization of the coating process was carried out by matrix analysis of orthogonal experiments to calculate the influence of the process parameters on the hardness, bonding and roughness indexes of the coating, determine the optimal coating process parameters, and focus on the influence of the bias voltage on the microscopic morphology, mechanical properties and friction properties of the coating. The results showed that the influence of the process parameters on the indexes of the orthogonal experiments was in the following order: bias voltage > arc current > N2 flow rate. The optimal solution was achieved with an arc current of 160 A, a bias voltage of −80 V, and a N2 flow rate of 600 sccm. Properly increasing the bias voltage improved the microscopic morphology, mechanical properties and wear resistance of the coating. When the bias voltage was −80 V, the coating surface presented fewer large particles with a less uniform size and no obvious crater defects; in addition, the cross-sectional structure changed from grape-like to columnar, and the coating had higher hardness, lower roughness and better bond strength. In the friction performance test, coating at a −80 V bias voltage showed better wear resistance, which was reflected in lower friction coefficient and wear, and the wear mechanism mainly consisted of adhesion and oxidation wear.

10.
Micromachines (Basel) ; 13(1)2022 Jan 08.
Article in English | MEDLINE | ID: mdl-35056263

ABSTRACT

Capacitive micromachined ultrasound transducers (CMUTs) have broad application prospects in medical imaging, flow monitoring, and nondestructive testing. CMUT arrays are limited by their fabrication process, which seriously restricts their further development and application. In this paper, a vacuum-sealed device for medical applications is introduced, which has the advantages of simple manufacturing process, no static friction, repeatability, and high reliability. The CMUT array suitable for medical imaging frequency band was fabricated by a silicon wafer bonding technology, and the adjacent array devices were isolated by an isolation slot, which was cut through the silicon film. The CMUT device fabricated following this process is a 4 × 16 array with a single element size of 1 mm × 1 mm. Device performance tests were conducted, where the center frequency of the transducer was 3.8 MHz, and the 6 dB fractional bandwidth was 110%. The static capacitance (29.4 pF) and center frequency (3.78 MHz) of each element of the array were tested, and the results revealed that the array has good consistency. Moreover, the transmitting and receiving performance of the transducer was evaluated by acoustic tests, and the receiving sensitivity was -211 dB @ 3 MHz, -213 dB @ 4 MHz. Finally, reflection imaging was performed using the array, which provides certain technical support for the research of two-dimensional CMUT arrays in the field of 3D ultrasound imaging.

11.
Micromachines (Basel) ; 12(12)2021 Dec 10.
Article in English | MEDLINE | ID: mdl-34945387

ABSTRACT

The exploration of marine resources has become an essential part of the development of marine strategies of various countries. MEMS vector hydrophone has great application value in the exploration of marine resources. However, existing MEMS vector hydrophones have a narrow frequency bandwidth and are based on rigid substrates, which are not easy to be bent in the array of underwater robots. This paper introduces a new type of flexible buckling crossbeam-cilium flexible MEMS vector hydrophone, arranged on a curved surface by a flexible substrate. A hydrophone model in the fluid domain was established by COMSOL Multiphysics software. A flexible hydrophone with a bandwidth of 20~4992 Hz, a sensitivity of -193.7 dB, excellent "8" character directivity, and a depth of concave point of 41.5 dB was obtained through structured data optimization. This study plays a guiding role in the manufacture and application of flexible hydrophones and sheds light on a new way of marine exploration.

12.
Micromachines (Basel) ; 12(10)2021 Oct 16.
Article in English | MEDLINE | ID: mdl-34683306

ABSTRACT

Silicon nano-film is essential for the rapidly developing fields of nanoscience and flexible electronics, due to its compatibility with the CMOS process. Viscoelastic PDMS material can adhere to Si, SiO2, and other materials via intermolecular force and play a key role in flexible electronic devices. Researchers have studied many methods of transfer printing silicon nano-films based on PDMS stamps with pyramid microstructures. However, only large-scale transfer printing processes of silicon nano-films with line widths above 20 µm have been reported, mainly because the distribution of pyramid microstructures proposes a request on the size of silicon nano-films. In this paper, The PDMS base to the curing agent ratio affects the adhesion to silicon and enables the transfer, without the need for secondary alignment photolithography, and a flat stamp has been used during the transfer printing, with no requirement for the attaching pressure and detaching speed. Transfer printing of 20 µm wide structures has been realized, while the success rate is 99.3%. The progress is promising in the development of miniature flexible sensors, especially flexible hydrophone.

13.
Microsyst Nanoeng ; 7: 1, 2021.
Article in English | MEDLINE | ID: mdl-34567721

ABSTRACT

Detecting low-frequency underwater acoustic signals can be a challenge for marine applications. Inspired by the notably strong response of the auditory organs of pectis jellyfish to ultralow frequencies, a kind of otolith-inspired vector hydrophone (OVH) is developed, enabled by hollow buoyant spheres atop cilia. Full parametric analysis is performed to optimize the cilium structure in order to balance the resonance frequency and sensitivity. After the structural parameters of the OVH are determined, the stress distributions of various vector hydrophones are simulated and analyzed. The shock resistance of the OVH is also investigated. Finally, the OVH is fabricated and calibrated. The receiving sensitivity of the OVH is measured to be as high as -202.1 dB@100 Hz (0 dB@1 V/µPa), and the average equivalent pressure sensitivity over the frequency range of interest of the OVH reaches -173.8 dB when the frequency ranges from 20 to 200 Hz. The 3 dB polar width of the directivity pattern for the OVH is measured as 87°. Moreover, the OVH is demonstrated to operate under 10 MPa hydrostatic pressure. These results show that the OVH is promising in low-frequency underwater acoustic detection.

14.
Micromachines (Basel) ; 12(7)2021 Jul 12.
Article in English | MEDLINE | ID: mdl-34357225

ABSTRACT

A hemispherical resonator consists of a hemispherical shell and the surrounding circular electrodes. The asymmetry of a hemispherical shell has influence on the vibrating mode and quality factor. The gap distance from shell to electrode is critical for the capacitance and sensitivity of a hemispherical resonator. To realize a symmetric shell and a small gap, a kind of micro-hemispherical resonator (µHR) structure including sandwich-shaped stacks and eave-shaped electrodes has been developed using a glassblowing process. The blowing process could bring favorable surface roughness and symmetry. The locations of the hemispherical shell and surrounding electrodes can be precisely controlled by the designs of sandwich-shaped stacks and eave-shaped electrodes, making it feasible to realize uniform and small gaps. In addition, electrical insulation between the hemispherical shell and eave-shaped electrodes can be guaranteed owing to eave-shaped structure. The fabrication process and results are demonstrated in detail. Furthermore, an estimation method of shell thickness in a nondestructive manner is proposed, with deviation below 5%. Taking asymmetry, surface roughness, and gap into consideration, these results preliminarily indicate this structure with a hemispherical shell and surrounding eave-shaped electrodes is promising in hemispherical resonator applications.

15.
Micromachines (Basel) ; 12(8)2021 Aug 10.
Article in English | MEDLINE | ID: mdl-34442561

ABSTRACT

The bionic cilium MEMS vector hydrophone has the characteristics of low power consumption, small volume, and good low-frequency response. Nevertheless, there exists the problem of left-right ambiguity in the azimuth estimation of a single hydrophone. In order to solve the engineering application problem, a sound-pressure sound-pressure-gradient hydrophone is designed in this paper. The new composite hydrophone consists of two channels. The bionic cilium microstructure is optimized and used as the vector channel, to collect the sound pressure gradient information, and a scalar channel, based on a piezoelectric ceramic tube, is added, to receive the sound pressure information. The theoretical analysis, simulation analysis, and test analysis of the composite hydrophone are carried out, respectively. The test results show that the sensitivities of the hydrophone can reach up to -188 dB (vector channel) and -204 dB (scalar channel). The problem of left-right ambiguity is solved by combining the sound pressure and sound pressure gradient in different ways. This is of great significance in the engineering application of single cilium MEMS hydrophone orientation.

16.
Micromachines (Basel) ; 12(2)2021 Feb 08.
Article in English | MEDLINE | ID: mdl-33567607

ABSTRACT

The principle of acoustic energy flux detection method using a single micro electromechanical system (MEMS) vector hydrophone is analyzed in this paper. The probability distribution of acoustic energy flux and the weighted histogram algorithm are discussed. Then, an improved algorithm is proposed. Based on the algorithm, the distribution range of the energy is obtained by a sliding window, the energy center of gravity in the range is considered as the result of direction of arrival (DOA) estimation, and it is proved to be the maximum likelihood estimation of the target direction. The simulation results show that, with the signal to noise ratio (SNR) from -10 dB to 10 dB, the root mean square error (RMSE) of the improved algorithm is reduced by 47.8% on average, and is more accurate in the presence of interference. The experimental results of lake test are consistent with the theory analysis and simulation results.

17.
Sensors (Basel) ; 21(1)2021 Jan 04.
Article in English | MEDLINE | ID: mdl-33406679

ABSTRACT

As a new material, graphene shows excellent properties in mechanics, electricity, optics, and so on, which makes it widely concerned by people. At present, it is difficult for graphene pressure sensor to meet both high sensitivity and large pressure detection range at the same time. Therefore, it is highly desirable to produce flexible pressure sensors with sufficient sensitivity in a wide working range and with simple process. Herein, a relatively high flexible pressure sensor based on piezoresistivity is presented by combining the conical microstructure polydimethylsiloxane (PDMS) with bilayer graphene together. The piezoresistive material (bilayer graphene) attached to the flexible substrate can convert the local deformation caused by the vertical force into the change of resistance. Results show that the pressure sensor based on conical microstructure PDMS-bilayer graphene can operate at a pressure range of 20 kPa while maintaining a sensitivity of 0.122 ± 0.002 kPa-1 (0-5 kPa) and 0.077 ± 0.002 kPa-1 (5-20 kPa), respectively. The response time of the sensor is about 70 ms. In addition to the high sensitivity of the pressure sensor, it also has excellent reproducibility at different pressure and temperature. The pressure sensor based on conical microstructure PDMS-bilayer graphene can sense the motion of joint well when the index finger is bent, which makes it possible to be applied in electronic skin, flexible electronic devices, and other fields.

18.
Sensors (Basel) ; 18(11)2018 Oct 26.
Article in English | MEDLINE | ID: mdl-30373206

ABSTRACT

A mathematical model of a sensor is vital to deeply comprehend its working principle and implement its optimal design. However, mathematical models of piezo-resistive eight-beam three-axis accelerometers have rarely been reported. Furthermore, those works are largely focused on the analysis of sensing acceleration in the normal direction, rather than in three directions. Therefore, a complete mathematical model of a piezo-resistive eight-beam three-axis accelerometer is developed in this paper. The validity of the mathematical model is proved by a Finite Element Method (FEM) simulation. Furthermore, the accelerometer is fabricated and tested. The prime sensitivities of X, Y and Z axes are 0.209 mV/g, 0.212 mV/g and 1.247 mV/g at 160 Hz, respectively, which is in accord with the values obtained by the model. The reason why the prime sensitivity SZZ is bigger than SXX and SYY is explained. Besides, it is also demonstrated why the cross-sensitivities SXZ and SYZ exceed SZX and SZY. Compared with the FEM model, the developed model could be helpful in evaluating the performance of three-axis accelerometers in an accurate and rapid way.

19.
Sensors (Basel) ; 16(12)2016 Nov 25.
Article in English | MEDLINE | ID: mdl-27897977

ABSTRACT

Electrostatic driving and capacitive detection is widely used in micro hemispheric shell resonators (HSR). The capacitor gap distance is a dominant factor for the initial capacitance, and affects the driving voltage and sensitivity. In order to decrease the equivalent gap distance, a micro HSR with annular electrodes fabricated by a glassblowing method was developed. Central and annular cavities are defined, and then the inside gas drives glass softening and deformation at 770 °C. While the same force is applied, the deformation of the hemispherical shell is about 200 times that of the annular electrodes, illustrating that the deformation of the electrodes will not affect the measurement accuracy. S-shaped patterns on the annular electrodes and internal-gear-like patterns on the hemispherical shell can improve metal malleability and avoid metal cracking during glass expansion. An arched annular electrode and a hemispheric shell are demonstrated. Compared with HSR with a spherical electrode, the applied voltage could be reduced by 29%, and the capacitance could be increased by 39%, according to theoretical and numerical calculation. The surface roughness of glass after glassblowing was favorable (Rq = 0.296 nm, Ra = 0.217 nm). In brief, micro HSR with an annular electrode was fabricated, and its superiority was preliminarily confirmed.

20.
Sensors (Basel) ; 16(10)2016 Oct 09.
Article in English | MEDLINE | ID: mdl-27735837

ABSTRACT

Silicon microneedle arrays (MNAs) have been widely studied due to their potential in various transdermal applications. However, discrete MNAs, as a preferred choice to fabricate flexible penetrating devices that could adapt curved and elastic tissue, are rarely reported. Furthermore, the reported discrete MNAs have disadvantages lying in uniformity and height-pitch ratio. Therefore, an improved technique is developed to manufacture discrete MNA with tunable height-pitch ratio, which involves KOH-dicing-KOH process. The detailed process is sketched and simulated to illustrate the formation of microneedles. Furthermore, the undercutting of convex mask in two KOH etching steps are mathematically analyzed, in order to reveal the relationship between etching depth and mask dimension. Subsequently, fabrication results demonstrate KOH-dicing-KOH process. {321} facet is figured out as the surface of octagonal pyramid microneedle. MNAs with diverse height and pitch are also presented to identify the versatility of this approach. At last, the metallization is realized via successive electroplating.

SELECTION OF CITATIONS
SEARCH DETAIL
...