Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Comput Methods Programs Biomed ; 252: 108236, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38776829

ABSTRACT

BACKGROUND AND OBJECTIVE: Strain analysis provides insights into myocardial function and cardiac condition evaluation. However, the anatomical characteristics of left atrium (LA) inherently limit LA strain analysis when using echocardiography. Cardiac computed tomography (CT) with its superior spatial resolution, has become critical for in-depth evaluation of LA function. Recent studies have explored the feasibility of CT-derived strain; however, they relied on manually selected regions of interest (ROIs) and mainly focused on left ventricle (LV). This study aimed to propose a first-of-its-kind fully automatic deep learning (DL)-based framework for three-dimensional (3D) LA strain extraction on cardiac CT. METHODS: A total of 111 patients undergoing ECG-gated contrast-enhanced CT for evaluating subclinical atrial fibrillation (AF) were enrolled in this study. We developed a 3D strain extraction framework on cardiac CT images, containing a 2.5D GN-U-Net network for LA segmentation, axis-oriented 3D view extraction, and LA strain measure. The segmentation accuracy was evaluated using Dice similarity coefficient (DSC). The model-extracted LA volumes and emptying fraction (EF) were compared with ground-truth measurements using intraclass correlation coefficient (ICC), correlation coefficient (r), and Bland-Altman plot (B-A). The automatically extracted LA strains were evaluated against the LA strains measured from 2D echocardiograms. We utilized this framework to gauge the effect of AF burden on LA strain, employing the atrial high rate episode (AHRE) burden as the measurement parameter. RESULTS: The GN-U-Net LA segmentation network achieved a DSC score of 0.9603 on the test set. The framework-extracted LA estimates demonstrated excellent ICCs of 0.949 (95 % CI: 0.93-0.97) for minimal LA volume, 0.904 (95 % CI: 0.86-0.93) for maximal LA volume, and 0.902 (95 % CI: 0.86-0.93) for EF, compared with expert measurements. The framework-extracted LA strains demonstrated moderate agreement with the LA strains based on 2D echocardiography (ICCs >0.703). Patients with AHRE > 6 min had significantly lower global strain and LAEF, as extracted by the framework than those with AHRE ≤ 6 min. CONCLUSION: The promising results highlighted the feasibility and clinical usefulness of automatically extracting 3D LA strain from CT images using a DL-based framework. This tool could provide a 3D-based alternative to echocardiography for assessing LA function.


Subject(s)
Atrial Fibrillation , Heart Atria , Imaging, Three-Dimensional , Tomography, X-Ray Computed , Humans , Heart Atria/diagnostic imaging , Heart Atria/physiopathology , Tomography, X-Ray Computed/methods , Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/physiopathology , Female , Male , Middle Aged , Aged , Deep Learning , Algorithms , Echocardiography/methods
2.
Heliyon ; 9(1): e12945, 2023 Jan.
Article in English | MEDLINE | ID: mdl-36699283

ABSTRACT

Rationale and objectives: Selecting region of interest (ROI) for left atrial appendage (LAA) filling defects assessment can be time consuming and prone to subjectivity. This study aimed to develop and validate a novel artificial intelligence (AI), deep learning (DL) based framework for automatic filling defects assessment on CT images for clinical and subclinical atrial fibrillation (AF) patients. Materials and methods: A total of 443,053 CT images were used for DL model development and testing. Images were analyzed by the AI framework and expert cardiologists/radiologists. The LAA segmentation performance was evaluated using Dice coefficient. The agreement between manual and automatic LAA ROI selections was evaluated using intraclass correlation coefficient (ICC) analysis. Receiver operating characteristic (ROC) curve analysis was used to assess filling defects based on the computed LAA to ascending aorta Hounsfield unit (HU) ratios. Results: A total of 210 patients (Group 1: subclinical AF, n = 105; Group 2: clinical AF with stroke, n = 35; Group 3: AF for catheter ablation, n = 70) were enrolled. The LAA volume segmentation achieved 0.931-0.945 Dice scores. The LAA ROI selection demonstrated excellent agreement (ICC ≥0.895, p < 0.001) with manual selection on the test sets. The automatic framework achieved an excellent AUC score of 0.979 in filling defects assessment. The ROC-derived optimal HU ratio threshold for filling defects detection was 0.561. Conclusion: The novel AI-based framework could accurately segment the LAA region and select ROIs while effectively avoiding trabeculae for filling defects assessment, achieving close-to-expert performance. This technique may help preemptively detect the potential thromboembolic risk for AF patients.

SELECTION OF CITATIONS
SEARCH DETAIL
...