Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Publication year range
1.
J Orthop Surg Res ; 15(1): 465, 2020 Oct 09.
Article in English | MEDLINE | ID: mdl-33036637

ABSTRACT

BACKGROUND: A growing number of patients continue to receive total knee replacement (TKR) surgery. Nevertheless, such surgeries result in moderate to severe postoperative pain and difficulty in managing it. Musical interventions are regarded as a type of multimodal analgesia, achieving beneficial results in other clinical treatments. This study aims to evaluate the effect of musical interventions in improving short-term pain outcomes following TKR in order to determine a more reasonable and standard way of delivering musical intervention. METHODS: A systematic search was conducted to identify available and relevant randomized controlled trials (RCTs) regarding musical interventions compared against non-musical interventions in patients treated with TKR in Embase, MEDLINE, Cochrane Library, Web of Science, CNKI, and Wanfang Med Online up to 8 January 2020. The authors independently assessed study eligibility and risk of bias and collected the outcomes of interest to analyze. The statistical analysis was conducted using the Review Manager (RevMan) version 5.30 software. RESULTS: Eight RCTs comprised of 555 patients satisfied the inclusion criteria and were enrolled in the present study. The results showed no significant difference between the music and control groups in pain of the visual analog scale (VAS), during postoperative recovery room, back to the ward after surgery; anxiety degree of VAS; heart rate; respiratory rate; oxygen saturation; blood pressure, systolic blood pressure, and diastolic blood pressure. Nevertheless, significant differences were observed between the two groups in average increase in continuous passive motion (CPM) angles and LF/HF ratio (one kind index of heart rate variability). CONCLUSIONS: Musical interventions fail to demonstrate an obvious effect in improving short-term pain outcomes following TKR. A reasonable standardization of musical interventions, including musical type, outcome measures used, outcomes measured, duration, timing and headphones or players, may improve pain outcomes with certain advantages and should be further explored after TKR.


Subject(s)
Arthroplasty, Replacement, Ankle/adverse effects , Music Therapy/methods , Pain Management/methods , Pain, Postoperative/etiology , Pain, Postoperative/therapy , Aged , Aged, 80 and over , Humans , Middle Aged , Music Therapy/standards , Pain Management/standards , Pain, Postoperative/psychology , Severity of Illness Index , Time Factors , Treatment Outcome
2.
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi ; 31(8): 913-917, 2017 08 15.
Article in Chinese | MEDLINE | ID: mdl-29806424

ABSTRACT

Objective: To evaluate the effectiveness of total knee arthroplasty (TKA) using three-dimensional (3D) printing technology for knee osteoarthritis (KOA) accompanied with extra-articular deformity. Methods: Between March 2013 and December 2015, 15 patients (18 knees) with extra-articular deformity and KOA underwent TKA. There were 6 males (6 knees) and 9 females (12 knees), aged 55-70 years (mean, 60.2 years). The mean disease duration was 10.8 years (range, 7-15 years). The unilateral knee was involved in 12 cases and bilateral knees in 3 cases. The clinical score was 57.44±1.06 and the functional score was 60.88±1.26 of Knee Society Score (KSS). The range of motion of the knee joint was (72.22±0.18)°. The deviation of mechanical axis of lower limb was (18.89±0.92)° preoperatively. There were 8 cases (10 knees) with extra-articular femoral deformity, 5 cases (5 knees) with extra-articular tibial deformity, and 2 cases (3 knees) with extra-articular femoral and tibial deformities. Bone models and the navigation templates were printed and the operation plans were designed using 3D printing technology. The right knee joint prostheses were chosen. Results: The operation time was 65-100 minutes (mean, 75.6 minutes). The bleeding volume was 50-150 mL (mean, 90.2 mL). There was no poor incision healing, infection, or deep venous thrombosis after operation. All patients were followed up 12- 30 months (mean, 22 months). Prostheses were located in the right place, and no sign of loosening or subsidence was observed by X-ray examination. At last follow-up, the deviation of mechanical axis of lower limb was (2.00±0.29)°, showing significant difference when compared with preoperative one ( t=13.120, P=0.007). The KSS clinical score was 87.50±0.88 and function score was 81.94±1.41, showing significant differences when compared with preoperative ones ( t=27.553, P=0.000; t=35.551, P=0.000). The range of motion of knee was (101.94±1.42)°, showing significant difference when compared with preoperative one ( t=31.633, P=0.000). Conclusion: For KOA accompanied with extra-articular deformity, TKA using 3D printing technology has advantages such as individualized treatment, reducing the difficulty of operation, and achieving the satisfactory function.


Subject(s)
Arthroplasty, Replacement, Knee , Knee Prosthesis , Osteoarthritis, Knee/surgery , Printing, Three-Dimensional , Aged , Female , Humans , Knee Joint , Male , Middle Aged , Range of Motion, Articular , Treatment Outcome
3.
Int J Clin Exp Med ; 8(9): 16352-7, 2015.
Article in English | MEDLINE | ID: mdl-26629156

ABSTRACT

To investigate the association of serum semaphorin 4D (Sema4D) levels with lumbar spine bone mineral density (BMD) and bone turnover markers in patients with postmenopausal osteoporosis (PO). Lumbar spine BMD was measured by dual-energy X-ray absorptiometry in 257 PO patients (aged from 50 to 75) and 90 healthy controls (aged from 51 to 83). Serum Sema4D, BAP, BGP and TRACP-5b levels were measured by enzyme linked immunosorbent assay. Serum cross linked N-telopeptides of type I (NTX), 25-hydroxyvitamin D (25(OH)D) and N-mid fragment of osteocalcin (N-MID-OT) levels were measured using automated electrochemiluminescence system. Sema4D level was significantly higher in PO women compared to healthy controls (1.40±0.33 vs. 0.58±0.18 µg/L, P=0.006). Sema4D level was positively correlated with serumTRACP-5b and NTX levels and negatively correlated with lumbar spine BMD and serum BAP and BGP levels. There were no correlations between Sema4D level and age, body mass index, and serum 25(OH)D and N-MID-OT levels. Lumbar spine BMD (ß=-0.354, P<0.001) and serum BAP level (ß=0.127, P=0.019) were independent predictors of serum Sema4D level in PO patients. Sema4D may be involved in the pathogenesis of PO and play a critical role in bone formation and resorption. Sema4D may represent a novel therapeutic target for treatment of PO and function as a predictive indicator of PO.

4.
Regen Biomater ; 2(3): 197-202, 2015 Sep.
Article in English | MEDLINE | ID: mdl-26816641

ABSTRACT

In artificial joint replacement, osteoclast bone resorption induced by wear debris of the implant is a main reason for aseptic loosening. To extend the life of the prosthesis, detailed mechanisms of aseptic loosening and the ways to prevent it should be explored. The aim of this study was to investigate the in vitro effect of icariine on the bone resorption of osteoclasts induced by titanium particles. Macrophage colony stimulating factor (M-CSF) and receptor activator of NF-kB ligand (RANKL) were used to generate osteoclasts from RAW264.7 precursors. The proliferation of RAW264.7 precursors in the presence of different doses of icariine was evaluated by MTT assay. The cells were treated with titanium particles, titanium particles with icariine and culture medium only (control), respectively. At 48 h after treatment, the expression level of receptor activator of NF-kB (RANK) was detected by ELISA, and messenger RNA (mRNA) levels of tartrate-resistant acid phosphatase (TRAP), matrix metalloproteinase 9 (MMP-9), carbonic anhydrase II (CAII) and Cathepsin K (CtsK) were determined by real-time polymerase chain reaction. Western blot was applied to analyze the expression levels of TRAP, RANK and CtsK. In addition, bone chips were cultured in the above conditions, and Toluidine blue staining was then employed to calculate the number and area of resorption pits in the bone chips. After treatment with icariine, expression level of RANK was significantly decreased in the RAW264.7 cell that induced by titanium particle and its cultural medium, mRNA and protein levels of TRAP, CAII, MMP-9 and CtsK were reduced as well. In addition, the numbers of bone resorption pits and areas on bone slices were both reduced by icariine challenging. Icariine could inhibit bone resorption of osteoclast induced by titanium particle, and it might be used as a promising drug for treating of aseptic loosening.

5.
Exp Ther Med ; 4(6): 1081-1086, 2012 Dec.
Article in English | MEDLINE | ID: mdl-23226778

ABSTRACT

The aim of the present study was to evaluate the stability of the figure of eight plus circular wiring fixation technique compared with four common internal fixation techniques and to provide experimental data for the selection of internal fixation techniques clinically. A total of 20 fresh cadaveric elbow joints were used as transverse, oblique and comminuted olecranon fracture models. Five techniques of internal fixation were investigated: circular wiring, figure of eight wiring, circular plus figure of eight wiring, Kirschner wire (K-wire) and screw fixation. The elbow joints were flexed at 90°. The fixation performance was tested using a high-precision displacement sensor. Displacement-load curves revealed that the strength of internal fixation was weakest when using circular wiring alone and that circular wiring plus figure of eight wiring fixation was stronger than that of figure of eight wiring or screw fixation. The difference was statistically significant (P<0.05). There were no significant differences between circular wiring plus figure of eight wiring fixation and K-wire fixation in the transverse and oblique fracture models (P>0.05). However, figure of eight plus circular wiring fixation was superior to K-wire fixation in the comminuted fracture model, with a tensile force of 67.42±2.17 vs. 58.52±2.17 N, respectively (P<0.05). All 152 patients with olecranon fractures who received circular wiring plus figure of eight wiring fixation recovered and 108 were included in the follow-up for an average of 12 months. The rate of excellent/fairly good recovery was 98.10%. Due to its reliability, simple surgery, lower invasiveness and lower cost, figure of eight plus circular wiring fixation is an ideal choice for the internal fixation of olecranon fractures, particularly comminuted fractures, compared with circular wiring, figure of eight wiring or screw fixation.

SELECTION OF CITATIONS
SEARCH DETAIL
...