Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Guang Pu Xue Yu Guang Pu Fen Xi ; 30(4): 1013-7, 2010 Apr.
Article in Chinese | MEDLINE | ID: mdl-20545151

ABSTRACT

Spatially modulated imaging Fourier transform spectrometer (SMIFTS) was an instrument that depended on interference, and after calibration, the reconstruction spectrum can quantificationally reflect the diffuse reflection of target under sunshine. On-board calibration of SMIFTS confirmed the change of SMIFTS according to relative spectrum calibration, inspected long-time attenuation of SMIFTS optical system, and corrected export data of SMIFTS. According to the requirement of remote sensor application, it must stay in vacuum environment for a long time. As a radiant standard, the stability of lamp-house in long time is the most important characteristic of on-board calibration system. By calculation and experimentation, analyses of on-board calibration of SMIFTS, and testing spaceflight environment characteristic of on-board calibration, the difficulty in the key parts of on-board calibration of SMIFTS such as lamp-house, spectrum filter and integrating sphere was solved. According to the radiation-time stability testing for lamp-house and optics, particle-radiation testing, environmental-mechanics testing and hot vacuum examination, good result was obtained. By whole-aperture and part-field comparative wavelength calibration, the spectrum curve and before-launch interferogram were obtained. After comparison with reconstruction spectrum under different condition, the stability and credibility of SMIFTS on-board calibration system was proved.

2.
Guang Pu Xue Yu Guang Pu Fen Xi ; 30(1): 142-5, 2010 Jan.
Article in Chinese | MEDLINE | ID: mdl-20302101

ABSTRACT

As a new type Fourier transform imaging spectrometry, large aperture static imaging spectrometry (LASIS) has come forth in recent years, which has many advantages such as simple principle, high stability and so on. However, the requirement for the optical system design of LASIS was very harsh. As one of the optical aberrations, optical distortion degrades the data quality acquired by LASIS, consequently limits its applications. According to the analysis of the data acquisition principle of LASIS, the data model with the effect of optical distortion was presented, which could be used for LASIS performance pre-evaluation. Finally, the computer simlulation of the data model was achieved with supposed parameters. The simulation results indicated that the relative error more than 5% was induced in the recovery spectrum, and approximate 8 nm spectral line deviation was occurred at the long wavelength region. The results show that the 4% optical distortion was inapplicable for LASIS although it is acceptant for common optical imaging system.

3.
Guang Pu Xue Yu Guang Pu Fen Xi ; 30(1): 278-82, 2010 Jan.
Article in Chinese | MEDLINE | ID: mdl-20302132

ABSTRACT

Fourier transform imaging spectrometer is a new technic, and has been developed very fast in recent ten years. When it is used in satellite, because of the limit by the data transmission, the authors need to compress the original data obtained by the Fourier transform imaging spectrometer, then, the data can be transmitted, and can be incepted on the earth and decompressed. Then the authors can do data process to get spectrum data which can be used by user. Data compression technic used in Fourier transform imaging spectrometer is a new technic, and few papers introduce it at home and abroad. In this paper the authors will give a data compression method, which has been used in EDIS, and achieved a good result.

SELECTION OF CITATIONS
SEARCH DETAIL
...