Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
1.
J Glaucoma ; 29(3): 191-197, 2020 03.
Article in English | MEDLINE | ID: mdl-32108691

ABSTRACT

PRECIS: We used the Open Perimetry Interface (OPI) to design a static automated perimetry test of the full visual field. About half of our glaucoma cohort had defects in the far peripheral inferotemporal visual field that correlate well with related damage to the superior nasal optic disc. AIMS: To test the hypothesis that in glaucoma patients with mild visual loss, perimetric nerve fiber bundle defects present outside 30 degrees will correlate well with areas of Cirrus ocular coherence tomography (OCT) retinal nerve fiber layer thinning. METHODS: We tested 27 consecutive glaucoma subjects with mild vision loss (mean deviation better than -4 dB) with a SITA standard test, 2 size V custom OPI tests (OPI 30-2 and OPI Peripheral) and Cirrus OCT. Two observers assigned qualitative grades to each type of visual field test based on their level of correlation with OCT retinal nerve fiber layer and ganglion cell thickness. RESULTS: Discrete temporal wedge defects were found on the OPI peripheral V test in 26% of cases whereas more extensive inferior temporal loss (including inferior temporal wedge defect region) was present in 22% of other cases. OCT data correlated best with the OPI peripheral test for 8 glaucoma subjects. The OPI central 30-2 test correlated best for 9 glaucoma subjects; the remainder of subjects had equal central/peripheral correlations. CONCLUSIONS: About half of our glaucoma cohort have defects in the far peripheral inferotemporal visual field that correlate well with related damage to the superior nasal optic disc. Adding a threshold automated perimetry test of the far periphery improves structure/function correlations and adds useful clinical information.


Subject(s)
Glaucoma, Open-Angle/diagnosis , Optic Disk/physiopathology , Optic Nerve Diseases/diagnosis , Visual Fields/physiology , Adolescent , Adult , Aged , Cohort Studies , Female , Glaucoma, Open-Angle/physiopathology , Humans , Intraocular Pressure/physiology , Male , Middle Aged , Nerve Fibers/pathology , Optic Nerve Diseases/physiopathology , Retinal Ganglion Cells/pathology , Tomography, Optical Coherence/methods , Vision Disorders/physiopathology , Visual Field Tests/methods , Young Adult
2.
J Glaucoma ; 28(11): 997-1005, 2019 11.
Article in English | MEDLINE | ID: mdl-31567907

ABSTRACT

PRECIS: The authors used the Open Perimetry Interface to design a static automated perimetry test of the full field. Abnormal test locations in the nasal midperiphery and temporal inferior sector area best separated glaucomas from normals. PURPOSE: The peripheral visual field in glaucoma outside 30 degrees is largely unexplored with static perimetry. Their goal was to use threshold static automated perimetry to characterize the visual loss in glaucoma of the central 30 degrees and the far periphery. PATIENTS AND METHODS: The authors administered the 30-2 perimetric test to 27 patients with early stage glaucoma (with mean deviation better than -4 dB) with the Goldmann III and V stimulus sizes and a custom test from 30 to up to 87 degrees with the size V stimulus twice within a month. The authors quantified (1) the retest variability, (2) the proportion of patients flagged as abnormal (at level 0.05) on the basis of pointwise probability distributions obtained from 63 ocular healthy observers, (3) the pointwise statistical distance using the Kullback-Leibler divergence between normal and glaucoma eyes, and (4) the effect of eccentricity on visual loss. RESULTS: Size V 30-2 testing identified significantly more abnormal test locations (36%) than size III 30-2 (30%; P=0.004). Kullback-Leibler divergence between healthy and glaucoma distributions was greatest for the nasal midperipheral test locations and the inferior temporal sector area. A more pronounced decrease was found in visual sensitivity with eccentricity in the patients with glaucoma compared with the ocular healthy participants across the full visual field (P<0.001). CONCLUSIONS: Patients with glaucoma demonstrate a systematic decrease in sensitivity with eccentricity across the full visual field. Goldmann size V stimuli better detected visual loss in patients with glaucoma with mild loss than size III.


Subject(s)
Glaucoma/diagnosis , Vision Disorders/diagnosis , Visual Field Tests , Visual Fields/physiology , Adolescent , Adult , Aged , Biometry , False Positive Reactions , Female , Glaucoma/physiopathology , Healthy Volunteers , Humans , Intraocular Pressure/physiology , Male , Middle Aged , Predictive Value of Tests , Reproducibility of Results , Vision Disorders/physiopathology , Young Adult
3.
J Clin Psychiatry ; 80(5)2019 09 03.
Article in English | MEDLINE | ID: mdl-31483958

ABSTRACT

BACKGROUND: Delirium is common and dangerous, yet underdetected and undertreated. Current screening questionnaires are subjective and ineffectively implemented in busy hospital workflows. Electroencephalography (EEG) can objectively detect the diffuse slowing characteristic of delirium, but it is not suitable for high-throughput screening due to size, cost, and the expertise required for lead placement and interpretation. This study hypothesized that an efficient and reliable point-of-care EEG device for high-throughput screening could be developed. METHODS: This prospective study, which measured bispectral EEG (BSEEG) from elderly inpatients to assess their outcomes, was conducted at the University of Iowa Hospitals and Clinics from January 2016 to October 2017. A BSEEG score was defined based on the distribution of 2,938 EEG recordings from the 428 subjects who were assessed for delirium; primary outcomes measured were hospital length of stay, discharge disposition, and mortality. RESULTS: A total of 274 patients had BSEEG score data available for analysis. Delirium and BSEEG score had a significant association (P < .001). Higher BSEEG scores were significantly correlated with length of stay (P < .001 unadjusted, P = .001 adjusted for age, sex, and Charlson Comorbidity Index [CCI] score) as well as with discharge not to home (P < .01). Hazard ratio for survival controlling for age, sex, CCI score, and delirium status was 1.35 (95% CI,1.04 to 1.76; P = .025). CONCLUSIONS: In BSEEG, an efficient and reliable device that provides an objective measurement of delirium status was developed. The BSEEG score is significantly associated with pertinent clinical outcomes of mortality, hospital length of stay, and discharge disposition. The BSEEG score better predicts mortality than does clinical delirium status. This study identified a previously unrecognized subpopulation of patients without clinical features of delirium who are at increased mortality risk.


Subject(s)
Consciousness Monitors , Delirium/diagnosis , Delirium/mortality , Electroencephalography/instrumentation , Aged , Female , Humans , Length of Stay/statistics & numerical data , Male , Patient Discharge/statistics & numerical data , Prognosis , Prospective Studies
SELECTION OF CITATIONS
SEARCH DETAIL
...