Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
PLoS One ; 14(10): e0223282, 2019.
Article in English | MEDLINE | ID: mdl-31600255

ABSTRACT

BACKGROUND: Fetal monitoring based on electrocardiographic (ECG) morphology is obtained from a single unipolar fetal scalp electrode. Ideally, it should be obtained from multiple leads, as ECG waveform depends on alignment between electrode and electrical heart axis. This alignment is unknown in fetuses. Besides, fetuses are surrounded by conductive media, which may influence ECG waveform. We explored the influence of electrode position and head orientation on ECG waveforms of unipolar and bipolar scalp ECGs recorded in air and in conductive medium. METHODS: We recorded ECGs in one adult subject at five different scalp positions in five different head orientations both in dry and immersed conditions. The ratio between T-amplitude and QRS-amplitude (T/QRS ratio) of unipolar and bipolar scalp ECGs was determined and compared between all conditions. RESULTS: In the dry condition, we observed in the unipolar leads little to no difference between different electrode positions (maximal T/QRS difference 0.00-0.01) and minor differences between head orientations (0.02-0.03), whereas bipolar leads showed no recognizable ECG signal at all. During the immersed condition, we found variation in the unipolar leads, both between electrode positions (maximal T/QRS difference 0.02-0.05) and between head orientations (0.03-0.06). Bipolar leads showed different ECG signals in contrasting head orientations. CONCLUSIONS: Both unipolar and bipolar scalp lead-derived ECG waveforms are influenced by electrode position and head orientation when the subject is submerged in a conductive medium. Fetal monitoring based on single scalp lead ECG waveform might be suboptimal, as it lacks correction for fetal head orientation and electrode position.


Subject(s)
Electrocardiography , Fetus/diagnostic imaging , Scalp/diagnostic imaging , Wavelet Analysis , Electrodes , Humans , Immersion
2.
Early Hum Dev ; 119: 8-14, 2018 04.
Article in English | MEDLINE | ID: mdl-29505915

ABSTRACT

BACKGROUND: Betamethasone is widely used to enhance fetal lung maturation in case of threatened preterm labour. Fetal heart rate variability is one of the most important parameters to assess in fetal monitoring, since it is a reliable indicator for fetal distress. AIM: To describe the effect of betamethasone on fetal heart rate variability, by applying spectral analysis on non-invasive fetal electrocardiogram recordings. STUDY DESIGN: Prospective cohort study. SUBJECTS: Patients that require betamethasone, with a gestational age from 24 weeks onwards. OUTCOME MEASURES: Fetal heart rate variability parameters on day 1, 2, and 3 after betamethasone administration are compared to a reference measurement. RESULTS: Following 68 inclusions, 12 patients remained with complete series of measurements and sufficient data quality. During day 1, an increase in absolute fetal heart rate variability values was seen. During day 2, a decrease in these values was seen. All trends indicate to return to pre-medication values on day 3. Normalised high- and low-frequency power show little changes during the study period. CONCLUSIONS: The changes in fetal heart rate variability following betamethasone administration show the same pattern when calculated by spectral analysis of the fetal electrocardiogram, as when calculated by cardiotocography. Since normalised spectral values show little changes, the influence of autonomic modulation seems minor.


Subject(s)
Betamethasone/adverse effects , Heart Rate, Fetal/drug effects , Obstetric Labor, Premature/prevention & control , Autonomic Nervous System/drug effects , Betamethasone/therapeutic use , Electrocardiography , Female , Humans , Pregnancy , Reference Values
3.
Acta Obstet Gynecol Scand ; 93(1): 93-101, 2014 Jan.
Article in English | MEDLINE | ID: mdl-24134552

ABSTRACT

OBJECTIVE: Non-invasive spectral analysis of fetal heart rate variability is a promising new field of fetal monitoring. To validate this method properly, we studied the relationship between gestational age and the influence of fetal rest-activity state on spectral estimates of fetal heart rate variability. DESIGN: Prospective longitudinal study. SETTING: Tertiary care teaching hospital. POPULATION: Forty healthy women with an uneventful singleton pregnancy. METHODS: Non-invasive fetal electrocardiogram measurements via the maternal abdomen were performed at regular intervals between 14 and 40 weeks of gestation and processed to detect beat-to-beat fetal heart rate. Simultaneous ultrasound recordings were performed to assess fetal rest-activity state. MAIN OUTCOME MEASURES: Absolute and normalized power of fetal heart rate variability in the low (0.04-0.15 Hz) and high (0.4-1.5 Hz) frequency band were obtained, using Fourier Transform. RESULTS: 14% of all measurements and 3% of the total amount of abdominal data (330 segments) was usable for spectral analysis. During 21-30 weeks of gestation, a significant increase in absolute low and high frequency power was observed. During the active state near term, absolute and normalized low frequency power were significantly higher and normalized high frequency power was significantly lower compared with the quiet state. CONCLUSIONS: The observed increase in absolute spectral estimates in preterm fetuses was probably due to increased sympathetic and parasympathetic modulation and might be a sign of autonomic development. Further improvements in signal processing are needed before this new method of fetal monitoring can be introduced in clinical practice.


Subject(s)
Heart Rate, Fetal/physiology , Adult , Electrocardiography/methods , Female , Fetal Monitoring/methods , Humans , Longitudinal Studies , Pregnancy
SELECTION OF CITATIONS
SEARCH DETAIL
...