Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
JA Clin Rep ; 9(1): 68, 2023 Oct 21.
Article in English | MEDLINE | ID: mdl-37864610

ABSTRACT

BACKGROUND: Reports on the effectiveness of spinal cord stimulation (SCS) for the alleviation of fibromyalgia syndrome (FMS) pain are scarce. We report two cases of effective high-frequency SCS at 1000 Hz against upper- and lower-limb pain in patients with FMS. CASE PRESENTATION: Two women with widespread pain were diagnosed with FMS and the pain gradually worsened. A 1-week SCS trial was conducted in each patient. In both cases, the patients complained of unpleasant sensations during 10-Hz SCS. However, the pain was alleviated after 1000-Hz stimulation without irritation. Therefore, leads and a generator were implanted, after which they felt almost no pain. Moreover, the dose of the oral medication could be reduced and the patients returned to their daily lives. CONCLUSION: SCS at 1000 Hz may effectively treat pain associated with FMS. Therefore, performing an SCS trial for patients with FMS with intractable pain might be worthwhile.

2.
BMC Anesthesiol ; 19(1): 83, 2019 05 22.
Article in English | MEDLINE | ID: mdl-31113379

ABSTRACT

BACKGROUND: In patients with paroxysmal nocturnal hemoglobinuria (PNH), the membrane-attack complex (MAC) formed on red blood cells (RBCs) causes hemolysis due to the patient's own activated complement system by an infection, inflammation, or surgical stress. The efficacy of transfusion therapy for patients with PNH has been documented, but no studies have focused on the perioperative use of salvaged autologous blood in patients with PNH. CASE PRESENTATION: A 71-year-old man underwent total hip replacement surgery. An autologous blood salvage device was put in place due to the large bleeding volume and the existence of an irregular antibody. The potassium concentration in the transfer bag of salvaged RBCs after the wash process was high at 6.2 mmol/L, although the washing generally removes > 90% of the potassium from the blood. This may have been caused by continued hemolysis even after the wash process. Once activated, the complement in patients with PNH forms the MAC on the RBCs, and the hemolytic reaction may not be stopped even with RBC washing. CONCLUSIONS: Packed RBCs, instead of salvaged autologous RBCs, should be used for transfusions in patients with PNH. The use of salvaged autologous RBCs in patients with PNH should be limited to critical situations, such as massive bleeding. Physicians should note that the hemolytic reaction may be present inside the transfer bag even after the wash process.


Subject(s)
Arthroplasty, Replacement, Hip/adverse effects , Hemoglobinuria, Paroxysmal/blood , Hemoglobinuria, Paroxysmal/diagnosis , Hemolysis/physiology , Operative Blood Salvage/methods , Aged , Arthroplasty, Replacement, Hip/trends , Blood Transfusion, Autologous/methods , Erythrocyte Transfusion/methods , Hemoglobinuria, Paroxysmal/therapy , Humans , Male
SELECTION OF CITATIONS
SEARCH DETAIL
...