Med Phys ; 43(8): 4607, 2016 Aug.
Article in English | MEDLINE | ID: mdl-27487877

ABSTRACT

PURPOSE: This paper presents an overview of multisource inverse-geometry computed tomography (IGCT) as well as the development of a gantry-based research prototype system. The development of the distributed x-ray source is covered in a companion paper [V. B. Neculaes et al., "Multisource inverse-geometry CT. Part II. X-ray source design and prototype," Med. Phys. 43, 4617-4627 (2016)]. While progress updates of this development have been presented at conferences and in journal papers, this paper is the first comprehensive overview of the multisource inverse-geometry CT concept and prototype. The authors also provide a review of all previous IGCT related publications. METHODS: The authors designed and implemented a gantry-based 32-source IGCT scanner with 22 cm field-of-view, 16 cm z-coverage, 1 s rotation time, 1.09 × 1.024 mm detector cell size, as low as 0.4 × 0.8 mm focal spot size and 80-140 kVp x-ray source voltage. The system is built using commercially available CT components and a custom made distributed x-ray source. The authors developed dedicated controls, calibrations, and reconstruction algorithms and evaluated the system performance using phantoms and small animals. RESULTS: The authors performed IGCT system experiments and demonstrated tube current up to 125 mA with up to 32 focal spots. The authors measured a spatial resolution of 13 lp/cm at 5% cutoff. The scatter-to-primary ratio is estimated 62% for a 32 cm water phantom at 140 kVp. The authors scanned several phantoms and small animals. The initial images have relatively high noise due to the low x-ray flux levels but minimal artifacts. CONCLUSIONS: IGCT has unique benefits in terms of dose-efficiency and cone-beam artifacts, but comes with challenges in terms of scattered radiation and x-ray flux limits. To the authors' knowledge, their prototype is the first gantry-based IGCT scanner. The authors summarized the design and implementation of the scanner and the authors presented results with phantoms and small animals.


Subject(s)
Tomography, X-Ray Computed/instrumentation , Tomography, X-Ray Computed/methods , Algorithms , Animals , Artifacts , Calibration , Equipment Design , Phantoms, Imaging , Polymethyl Methacrylate , Rabbits , Radiation Dosage , Rats , Scattering, Radiation , Tomography Scanners, X-Ray Computed , Water , X-Rays
SELECTION OF CITATIONS
SEARCH DETAIL
...