Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
1.
J Interv Card Electrophysiol ; 36(1): 81-6; discussion 86, 2013 Jan.
Article in English | MEDLINE | ID: mdl-22869386

ABSTRACT

INTRODUCTION: Implantation of cardiac resynchronization therapy (CRT) devices is technically challenging and can be limited by lead dislodgement. The Attain Starfix active fixation coronary sinus (CS) lead (model 4195, Medtronic, Minneapolis, MN, USA) was introduced to reduce the rate of lead dislodgement, but the active fixation mechanism presents additional difficulties should these leads require extraction. METHODS: CS lead extraction procedures at our institution from 2003 to 2011 were reviewed. Procedural variables were compared between extraction of the Starfix lead and passive fixation CS leads. Attempts at reimplantation post Starfix lead extraction were examined. RESULTS: Four Starfix CS leads were extracted in four patients during this time period. The mean implant duration was 784 days (range, 392-1,029 days). The indication for extraction was infection in all four cases. Mean total procedure time was 141.5 min (range, 92-205 min). None of the fixation lobes could be retracted in one lead and only the most proximal lobes could be retracted in the remaining three leads. All four leads were removed in their entirety. The excimer laser sheath (Spectranetics Laser Sheath II, Spectranetics Corp., Colorado Springs, CO,USA) was required to remove the lead in all 4 cases (100 %) compared to 25 of 131 (19.1 %) of passive fixation CS lead extractions (mean implant duration, 659 ± 697 days) performed at our institution over the same time period (P < 0.001). In three cases, the laser sheath had to be advanced past the CS ostium to remove the Starfix lead. After extraction, fibrous material which had grown between the lobes of the fixation mechanism was noted in all four cases. No complications occurred. Transvenous CS lead reimplantation was attempted at a median of 7.5 days post extraction in all four patients. The original target branch was occluded in three patients and the main CS in one patient. Reimplantation was successful in another branch of the CS in three of four patients; one underwent minimally invasive epicardial lead placement. CONCLUSIONS: The Starfix active fixation CS lead presents additional procedural complexity and uniform use of excimer laser sheath compared to other CS leads. Reimplantation was not possible in the same venous branch in our experience.


Subject(s)
Cardiac Resynchronization Therapy Devices/adverse effects , Device Removal/methods , Aged , Electrodes, Implanted , Equipment Design , Equipment Failure , Humans , Laser Therapy , Male , Middle Aged , Phlebography , Reoperation
2.
Heart ; 92(2): 190-5, 2006 Feb.
Article in English | MEDLINE | ID: mdl-15923278

ABSTRACT

OBJECTIVE: To assess prospectively whether preimplantation B-type natriuretic peptide (BNP) and C reactive protein (CRP) concentrations predict future appropriate therapies from an implantable cardioverter-defibrillator (ICD). DESIGN AND SETTING: Prospective cohort study conducted in a tertiary cardiac care centre. METHODS: 345 consecutive patients undergoing first time ICD implantation were prospectively studied. Serum BNP and CRP concentrations were obtained the day before ICD implantation. Patients were followed up with device interrogation to assess for appropriate shocks or antitachycardia pacing. Inappropriate therapies were excluded. Mean (SD) follow up was 13 (5) months. RESULTS: Patients had ischaemic (71%), primary dilated (17%), and valvar or other cardiomyopathies (12%). About half (52%) had ICDs implanted for primary prevention. Sixty three (18%) received appropriate ICD therapies. Serum creatinine, beta blocker, statin, and angiotensin converting enzyme inhibitor usage did not differ between therapy and no therapy groups. By univariate comparison, ejection fraction (p = 0.048), not taking amiodarone (p = 0.033), and BNP concentration (p = 0.0003) were risk factors for ICD therapy. However, by Cox regression multivariate analysis, only BNP above the 50th centile was a significant predictor (hazard ratio 2.19, 95% confidence interval 1.07 to 4.71, p = 0.040). Median BNP was 573 ng/l versus 243 ng/l in therapy and no therapy patients, respectively (p = 0.0003). More patients with BNP above the 50th centile (27% v 10%, p = 0.006) received ICD therapies. CONCLUSIONS: A single preimplantation BNP concentration determination is independently predictive of ICD therapies in patients with cardiomyopathies undergoing first time ICD implantation. CRP was not independently predictive of ICD therapies when compared with BNP.


Subject(s)
Coronary Artery Disease/therapy , Defibrillators, Implantable/statistics & numerical data , Natriuretic Peptide, Brain/blood , Biomarkers/blood , C-Reactive Protein/analysis , Epidemiologic Methods , Female , Humans , Male , Middle Aged
3.
Heart ; 91(10): 1303-5, 2005 Oct.
Article in English | MEDLINE | ID: mdl-15890767

ABSTRACT

BACKGROUND: To test the hypothesis that a high C reactive protein (CRP) concentration would predict recurrence of atrial fibrillation (AF) after cardioversion in patients taking antiarrhythmic drugs. METHODS: 111 patients who underwent direct current cardioversion for symptomatic AF were enrolled. Blood was drawn for CRP determination before cardioversion on the same day. All patients were taking antiarrhythmic drugs before and after electrical cardioversion. RESULTS: After a mean follow up of 76 days, 75 patients had recurrence of AF. In univariate analysis, the median CRP concentration was significantly higher in patients with AF recurrence (3.95 mg/l v 1.81 mg/l, p = 0.002). Among the 55 patients with CRP in the upper 50th centile, 44 (80%) experienced recurrence of AF over a total follow up of 8.98 patient years, whereas among the 56 patients with CRP in the lower 50th centile, 31 (55%) experienced recurrence of AF over a total follow up of 14.3 patient years (p < 0.001). The adjusted hazard ratio comparing the upper 50th centile of CRP with the lower 50th centile of CRP was 2.0 (95% confidence interval 1.2 to 3.2, p = 0.007). CONCLUSIONS: CRP is independently associated with recurrence of AF after electrical cardioversion among patients taking antiarrhythmic drugs. These results suggest that inflammation may have a role in the pathogenesis of AF resistant to antiarrhythmic drugs.


Subject(s)
Atrial Fibrillation/therapy , C-Reactive Protein/metabolism , Electric Countershock/methods , Aged , Atrial Fibrillation/blood , Biomarkers/blood , Female , Follow-Up Studies , Humans , Male , Recurrence , Regression Analysis
4.
Circulation ; 104(24): 2886-91, 2001 Dec 11.
Article in English | MEDLINE | ID: mdl-11739301

ABSTRACT

BACKGROUND: Atrial fibrillation (AF) may persist due to structural changes in the atria that are promoted by inflammation. C-reactive protein (CRP), a marker of systemic inflammation, predicts cardiovascular events and stroke, a common sequela of AF. We hypothesized that CRP is elevated in patients with atrial arrhythmias. METHODS AND RESULTS: Using a case-control study design, CRP in 131 patients with atrial arrhythmias was compared with CRP in 71 control patients. Among arrhythmia patients, 6 had frequent atrial ectopy or tachycardia, 86 had paroxysmal AF, 39 had persistent AF lasting >30 days, and 70 had lone arrhythmias. CRP was higher in arrhythmia than in control patients (median, 0.21 versus 0.096 mg/dL; P<0.001). Arrhythmia patients in AF within 24 hours before sampling had higher CRP than those in sinus rhythm (0.30 versus 0.15 mg/dL; P<0.001). CRP in controls was not different than in patients with atrial ectopy or tachycardia. Lone arrhythmia patients had a CRP of 0.21 mg/dL, which was not significantly lower than arrhythmia patients with structural heart disease (CRP, 0.23 mg/dL) but higher than controls (P=0.002). Persistent AF patients had a higher CRP (0.34 mg/dL) than paroxysmal AF patients (0.18 mg/dL; P=0.008); both groups had higher CRP levels than controls (P

Subject(s)
Arrhythmias, Cardiac/metabolism , C-Reactive Protein/metabolism , Heart Atria/metabolism , Analysis of Variance , Atrial Fibrillation/metabolism , Case-Control Studies , Female , Heart Atria/physiopathology , Humans , Inflammation/metabolism , Male , Middle Aged
5.
Stroke ; 32(10): 2328-32, 2001 Oct.
Article in English | MEDLINE | ID: mdl-11588321

ABSTRACT

BACKGROUND AND PURPOSE: Abciximab has been shown to decrease periprocedural ischemic complications after coronary intervention. However, the adjunctive use of abciximab in carotid stenting has not been adequately studied. We sought to determine the efficacy and safety of abciximab in carotid stenting. METHODS: Carotid stenting was performed in 151 consecutive patients determined to be at high surgical risk by a vascular surgeon. Of these, 128 consecutive patients received adjuvant therapy with abciximab (0.25 mg/kg bolus before the lesion was crossed with guidewire and 0.125 micro. kg(-1). min(-1) infusion for 12 hours.). A heparin bolus of 50 U/kg was given, and activated clotting time was maintained between 250 to 300 seconds. All patients received aspirin and thienopyridine. Procedural and 30-day outcomes were compared between the control (n=23) and abciximab (n=128) groups. RESULTS: The 2 groups had similar baseline characteristics. Procedural events were more frequent in the control group (8%; 1 major stroke and 1 neurological death) compared with the abciximab group (1.6%; 1 minor stroke and 1 retinal infarction; P=0.05). On 30-day follow-up, 1 patient presented with delayed intracranial hemorrhage in the abciximab group. There were no other major bleeding complications. CONCLUSIONS: Adjunctive use of abciximab for carotid stenting is safe with no increase in the risk of intracranial hemorrhage. This adjunctive therapy with potent glycoprotein IIb/IIIa inhibition may help to reduce periprocedural adverse events in patients undergoing carotid stenting.


Subject(s)
Antibodies, Monoclonal/therapeutic use , Blood Vessel Prosthesis Implantation , Carotid Artery Diseases/surgery , Immunoglobulin Fab Fragments/therapeutic use , Platelet Glycoprotein GPIIb-IIIa Complex/antagonists & inhibitors , Stents , Thromboembolism/prevention & control , Abciximab , Adjuvants, Pharmaceutic/therapeutic use , Aged , Antibodies, Monoclonal/adverse effects , Blood Vessel Prosthesis Implantation/adverse effects , Female , Graft Occlusion, Vascular/etiology , Graft Occlusion, Vascular/prevention & control , Humans , Immunoglobulin Fab Fragments/adverse effects , Intracranial Hemorrhages/etiology , Male , Platelet Aggregation Inhibitors/therapeutic use , Risk Assessment , Risk Factors , Stents/adverse effects , Thromboembolism/etiology , Treatment Outcome , Urokinase-Type Plasminogen Activator/therapeutic use
SELECTION OF CITATIONS
SEARCH DETAIL
...