Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Diagn Interv Radiol ; 28(2): 166-170, 2022 Mar.
Article in English | MEDLINE | ID: mdl-35548901

ABSTRACT

PURPOSE Paracentesis is commonly performed in interventional radiology practice, and large volume paracentesis (LVP) using wall suction can take up to an hour to complete, placing significant stress on room and resource time. As the number of LVP procedures performed by Interventional Radiologists continue to increase, this study was undertaken to analyze the impact of the RenovaRP® Paracentesis Management System (GI Supply) on procedure time and patient satisfaction. METHODS Between March 9, 2020 and May 29, 2020, procedural data and patient satisfaction was collected as part of a practice quality improvement project and retrospectively analyzed on 39 sequential paracenteses performed with wall suction prior to acquiring the RenovaRP® system and subsequently on 42 paracenteses performed with use of the device. RESULTS A substantially higher fluid flow rate was found using the RenovaRP® system compared to wall suction, 237.2 mL/min vs. 108.6 mL/min (P < .001). This resulted in a significant decrease in procedure room time from 53 min to 31 min (P < .001). There was associated improvement in the patient experience during paracentesis. CONCLUSION The RenovaRP® decreases procedure time for LVP with improvement in the patient experience during paracentesis.


Subject(s)
Ascites , Paracentesis , Humans , Liver Cirrhosis , Paracentesis/methods , Retrospective Studies , Suction
2.
Health Phys ; 103(3): 286-300, 2012 Sep.
Article in English | MEDLINE | ID: mdl-22850234

ABSTRACT

Skin penetration by radionuclide contaminants serves as a route of entry into the body and may pose a serious health risk to humans depending on the magnitude of intake. The United States Transuranium and Uranium Registry whole body Case 0262 was involved in a wound intake of plutonium at the Hanford Site. The registrant died about 33 years later. Results were initially reported in 2007 regarding the deposition and retention of plutonium in various tissues, including the wound site. However in 2009, an additional (previously unrecorded) sample of the wound tissue was located in the National Human Radiobiological Tissue Repository. The new sample was analyzed using inductively coupled plasma-mass spectrometry (ICP-MS), and the results were used to calibrate the measurement of emitted Pu x-rays from the original wound tissue sample made in 2007. In the present study, the analysis of Pu absorption rates from the wound and axillary lymph node from the initial study is repeated using the additional wound activity data and ICP-MS calibration. This new analysis is carried out using the Weighted Likelihood Monte Carlo Sampling (WeLMoS) method and code, which applies Bayesian inference to calculate the posterior probability distribution of intake and wound absorption parameters directly from the observed data and the assumed biokinetic model structure. The resulting central estimates of empirical wound absorption parameters and their associated uncertainties are here compared with the empirical values recommended in NCRP Report No. 156 for plutonium and with the maximum likelihood point estimates derived in the initial study from the Case 0262 data available at the time.


Subject(s)
Plutonium/metabolism , Registries , Skin/injuries , Skin/metabolism , Bayes Theorem , Humans , Male , Plutonium/adverse effects , Skin/radiation effects
SELECTION OF CITATIONS
SEARCH DETAIL
...