Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters










Database
Publication year range
1.
RSC Adv ; 12(52): 33928-33935, 2022 Nov 22.
Article in English | MEDLINE | ID: mdl-36505708

ABSTRACT

In this paper, the potential energy curves of 22 Λ-S states as well as 51 Ω states were calculated using the internally contracted multiconfiguration interaction and Davidson correction method. Through the obtained transition data, the spectroscopy data of the low excitation bound state are fitted and compared with the same main group ions. The phenomenon of avoided crossing that occurs in the Ω state is analyzed, and finally it is concluded that this phenomenon mainly occurs in the energy region between 20 000 cm-1 and 40 000 cm-1. The potential laser cooling transition cycle in the Ω state is analyzed. The Franck-Condon factor, radiative lifetime and Einstein coefficient between are calculated. In this paper, we argue that direct laser cooling of SeBr+ is not feasible. The content of our study provides a theoretical basis for subsequent calculations to explore the properties of SeBr+ spectrum.

2.
Guang Pu Xue Yu Guang Pu Fen Xi ; 34(1): 180-4, 2014 Jan.
Article in Chinese | MEDLINE | ID: mdl-24783557

ABSTRACT

Aiming at the technological shortage of national standard method for the determination of total phosphorus, a rapid determination method of total phosphorus based on ultrasonic assisted sample digestion-spectrum analysis was put forward, and the on-line analysis experiment system was designed. Relying on the experiment system, the experimental method and technology was studied. In view of the actual environmental water samples, contrast test experiment with the national standard method for determination method of total phosphorus was carried on. The experimental results showed that the digestion rate of ultrasonic assisted sample digestion using fenton reagents could reach 97%-100% in 13.5 minutes, and the determination method could complete one copy of sample analysis within 16 minutes. This determination method can solve national standard method's technical problems. All of this research work provides the important experimental basis and technical support for the development of the rapid on-line monitoring instrument for determination of total phosphorus.

3.
Guang Pu Xue Yu Guang Pu Fen Xi ; 34(12): 3368-73, 2014 Dec.
Article in Chinese | MEDLINE | ID: mdl-25881441

ABSTRACT

Based on continuous spectrum analysis, the mathematical model for spectrum signal was established. And the spectrum signal's systematic error processing method based on the invariance of the ratio of the light intensities at any two wavelengths in the range of continuous spectrum was put forward. Combined with wavelet multi-resolution filtering noise processing techniques, the background interference processing method was established based on the spectral characteristics of the measured water quality parameter. These signal processing methods were applied to our independently developed multi-parameter water quality monitoring instrument to on-line measure COD (chemical oxygen demand), six valence chromium and anionic surfactant in the normative and actual environmental water samples, and the monitoring instrument had good repeatability (10%) and high accuracy (±10%) to meet the technical requirements of national environmental protection standards, which was verified by the contrast experiment with China national standard analysis method for determination of the three water quality parameter. The results showed that the researched signal processing methods were able to effectively reduce the spectrum signal's systematic error and the interference from noise and background, which was very important to improve the water quality monitoring instrument's technical function.

4.
Guang Pu Xue Yu Guang Pu Fen Xi ; 33(7): 1796-800, 2013 Jul.
Article in Chinese | MEDLINE | ID: mdl-24059177

ABSTRACT

The method based on miniature near-infrared spectrometer combined with Y fiber optic probe to detect the protein and fat in milk powder by diffuse reflectance spectroscopy in the wavelength range of 900-1 700 nm was proposed. By selecting the appropriate spectral bands, the correction models of protein and fat were established with partial least squares algorithm using Unscrambler 9.7 Chemometrics software. The determination coefficients R2 of the correction modes are 0.987 and 0.986 for protein and fat respectively, and the root mean square errors RMSEC are 0.385 and 0.419 respectively. Using these correction models to predict the protein and fat contents with 30 sets of forecast sample data, the prediction standard deviation is SEP(Protein) = 0.751 for protein, and is SEP(Fat) = 1.109 for fat. The results indicate that these correction models have prediction capability with unknown samples and meet the on line requirements.


Subject(s)
Dietary Fats/analysis , Fiber Optic Technology , Milk Proteins/analysis , Milk/chemistry , Spectroscopy, Near-Infrared/methods , Algorithms , Animals , Cattle , Fiber Optic Technology/instrumentation , Powders , Spectroscopy, Near-Infrared/instrumentation
5.
Guang Pu Xue Yu Guang Pu Fen Xi ; 33(4): 1098-103, 2013 Apr.
Article in Chinese | MEDLINE | ID: mdl-23841436

ABSTRACT

The water quality monitoring technology based on ultraviolet spectrum analysis has the characteristics of small volume, low cost, and no secondary pollution, and it doesn't need any reagent and sample pretreatment. On account of these characteristics, the direct ultra-violet technology has remarkable superiority over traditional technologies when applied in online monitoring of drinking water, surface water and industrial wastewater, and it has become an important development tendency of modern water monitoring technologies. The principle, characteristics, present situation and development trend of modern water quality monitoring technology based on ultra-violet spectrum analysis were introduced, and the key technical problems were further discussed in this paper.

6.
Guang Pu Xue Yu Guang Pu Fen Xi ; 32(7): 2009-14, 2012 Jul.
Article in Chinese | MEDLINE | ID: mdl-23016374

ABSTRACT

Aiming at the monitoring and protecting of water resource environment, a multi-parameter water quality monitoring microsystem based on microspectrometer was put forward in the present paper. The microsystem is mainly composed of MOEMS microspectrometer, flow paths system and embedded measuring & controlling system. It has the functions of self-injecting samples and detection regents, automatic constant temperature, self -stirring, self- cleaning and samples' spectrum detection. The principle prototype machine of the microsystem was developed, and its structure principle was introduced in the paper. Through experiment research, it was proved that the principle prototype machine can rapidly detect quite a few water quality parameters and can meet the demands of on-line water quality monitoring, moreover, the principle prototype machine has strong function expansibility.

7.
Guang Pu Xue Yu Guang Pu Fen Xi ; 31(4): 1074-7, 2011 Apr.
Article in Chinese | MEDLINE | ID: mdl-21714263

ABSTRACT

The application of spectral analysis to water quality monitoring is an important developing trend in the field of modern environment monitoring technology. The principle and characteristic of water quality monitoring technology based on UV-Vis spectrum analysis are briefly reviewed. And the research status and advances are introduced from two aspects, on-line monitoring and in-situ monitoring. Moreover, the existent key technical problems are put forward. Finally, the technology trends of multi-parameter water quality monitoring microsystem and microsystem networks based on microspectrometer are prospected, which has certain reference value for the research and development of environmental monitoring technology and modern scientific instrument in the authors' country.

SELECTION OF CITATIONS
SEARCH DETAIL
...