Plast Reconstr Surg ; 152(4): 670e-674e, 2023 10 01.
Article in English | MEDLINE | ID: mdl-36952590

ABSTRACT

SUMMARY: Digital-nerve lesions result in a loss of tactile sensation reflected by an anesthetic area (AA) at the radial or ulnar aspect of the respective digit. Available tools to monitor the recovery of tactile sense have been criticized for their lack of validity. Precise quantification of AA dynamics by three-dimensional (3D) imaging could serve as an accurate surrogate to monitor recovery after digital-nerve repair. For validation, AAs were marked on digits of healthy volunteers to simulate the AA of an impaired cutaneous innervation. The 3D models were composed from raw images that had been acquired with a 3D camera to precisely quantify relative AA for each digit (3D models, n = 80). Operator properties varied with regard to individual experience in 3D imaging and image processing. In addition, the concept was applied in a clinical case study. Results showed that images taken by experienced photographers were rated as better quality ( P < 0.001) and needed less processing time ( P = 0.020). Quantification of the relative AA was not altered significantly, regardless of experience level of the photographer ( P = 0.425) or image assembler ( P = 0.749). The proposed concept allows precise and reliable surface quantification of digits and can be performed consistently without relevant distortion by lack of examiner experience. Routine 3D imaging of the AA has the great potential to provide visual evidence of various returning states of sensation and to convert sensory nerve recovery into a metric variable with high responsiveness to temporal progress.


Subject(s)
Sensation , Touch Perception , Humans , Touch , Image Processing, Computer-Assisted , Skin , Imaging, Three-Dimensional/methods
3.
Aesthetic Plast Surg ; 46(5): 2228-2236, 2022 Oct.
Article in English | MEDLINE | ID: mdl-35296928

ABSTRACT

AIMS: Congenital breast asymmetry represents a particular challenge to the classic techniques of plastic surgery given the young age of patients at presentation. This study reviews and compares the long-term results of traditional breast augmentation using silicone implants and the more innovative technique of lipografting. METHODS: To achieve this, we not only captured subjective parameters such as satisfaction with outcome and symmetry, but also objective parameters including breast volume and anthropometric measurements. The objective examination was performed manually and by using the Vectra® H2 photogrammetry scanning system. RESULTS: Differences between patients undergoing either implant augmentation or lipograft were revealed not to be significant with respect to patient satisfaction with surgical outcome (p = 0.55) and symmetry (p = 0.69). Furthermore, a breast symmetry of 93 % was reported in both groups. Likewise, no statistically significant volume difference between the left and right breasts was observed in both groups (p < 0.41). However, lipograft patients needed on average 2.9 procedures to achieve the desired result, compared with 1.3 for implant augmentation. In contrast, patients treated with implant augmentation may require a number of implant changes during their lifetime. CONCLUSION: Both methods may be considered for patients presenting with congenital breast asymmetry. LEVEL OF EVIDENCE III: This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .


Subject(s)
Breast Implants , Mammaplasty , Humans , Esthetics , Mammaplasty/methods , Breast/surgery , Silicones
4.
Arch Gynecol Obstet ; 305(1): 95-102, 2022 01.
Article in English | MEDLINE | ID: mdl-34480228

ABSTRACT

PURPOSE: Congenital breast asymmetry is a serious gynecological malformation for affected patients. The condition hits young women in puberty and is associated with socio-esthetic handicap, depression, and psychosexual problems. Surgical treatment is usually early in the patient's lifetime, so a long-term sustainable solution is important. Although postoperative outcome has been evaluated in several studies before, this study is the first to analyze which objective parameters have the greatest influence on subjective satisfaction with long-term results. METHODS: Thirty-four patients diagnosed with congenital breast asymmetry that underwent either lipofilling or implant therapy between the years of 2008 to 2019 were examined. On average, our collective comprised patients seven years after surgery. Data were mainly gathered through manual measurements, patient-reported outcome measures (Breast Q™), and breast volumetry based on 3D scans (Vectra® H2, Canfield Scientific). RESULTS: Among all analyzed parameters, only areolar diameter correlated significantly negatively with the subjective outcome satisfaction of the patient. Regarding the subjective assessment of postoperative satisfaction with similarity of the breasts, again the mean areolar diameter, but also the difference in areolar diameter and breast volume between the right and left breasts correlated significantly negatively. CONCLUSION: Areolar diameter was revealed as being a significant factor influencing subjective long-term satisfaction in breast asymmetry patients. Moreover, 3D volumetry proves to be an effective tool to substantiate subjective patient assessments. Our findings may lead to further improvements to surgical planning and will be expanded in further studies.


Subject(s)
Breast , Mammaplasty , Patient Satisfaction , Body Weights and Measures , Breast/abnormalities , Breast/pathology , Breast/surgery , Breast Implants/psychology , Congenital Abnormalities/pathology , Congenital Abnormalities/surgery , Female , Humans , Imaging, Three-Dimensional , Mammaplasty/methods , Mammaplasty/psychology , Nipples/pathology , Nipples/surgery , Organ Size , Patient Reported Outcome Measures , Treatment Outcome
6.
Arch Gynecol Obstet ; 303(3): 721-728, 2021 03.
Article in English | MEDLINE | ID: mdl-33184690

ABSTRACT

PURPOSE: In this trial, we used a previously developed prototype software to assess aesthetic results after reconstructive surgery for congenital breast asymmetry using automated anthropometry. To prove the consensus between the manual and automatic digital measurements, we evaluated the software by comparing the manual and automatic measurements of 46 breasts. METHODS: Twenty-three patients who underwent reconstructive surgery for congenital breast asymmetry at our institution were examined and underwent 3D surface imaging. Per patient, 14 manual and 14 computer-based anthropometric measurements were obtained according to a standardized protocol. Manual and automatic measurements, as well as the previously proposed Symmetry Index (SI), were compared. RESULTS: The Wilcoxon signed-rank test revealed no significant differences in six of the seven measurements between the automatic and manual assessments. The SI showed robust agreement between the automatic and manual methods. CONCLUSION: The present trial validates our method for digital anthropometry. Despite the discrepancy in one measurement, all remaining measurements, including the SI, showed high agreement between the manual and automatic methods. The proposed data bring us one step closer to the long-term goal of establishing robust instruments to evaluate the results of breast surgery. LEVEL OF EVIDENCE: IV.


Subject(s)
Breast/anatomy & histology , Imaging, Three-Dimensional/methods , Magnetic Resonance Imaging/methods , Adult , Anthropometry/methods , Esthetics , Female , Humans , Mastectomy , Reproducibility of Results , Software
7.
Aesthetic Plast Surg ; 44(6): 1980-1987, 2020 12.
Article in English | MEDLINE | ID: mdl-32405724

ABSTRACT

BACKGROUND: Breast reconstruction is an important coping tool for patients undergoing a mastectomy. There are numerous surgical techniques in breast reconstruction surgery (BRS). Regardless of the technique used, creating a symmetric outcome is crucial for patients and plastic surgeons. Three-dimensional surface imaging enables surgeons and patients to assess the outcome's symmetry in BRS. To discriminate between autologous and alloplastic techniques, we analyzed both techniques using objective optical computerized symmetry analysis. Software was developed that enables clinicians to assess optical breast symmetry using three-dimensional surface imaging. METHODS: Twenty-seven patients who had undergone autologous (n = 12) or alloplastic (n = 15) BRS received three-dimensional surface imaging. Anthropomorphic data were collected digitally using semiautomatic measurements and automatic measurements. Automatic measurements were taken using the newly developed software. To quantify symmetry, a Symmetry Index is proposed. RESULTS: Statistical analysis revealed that there is no difference in the outcome symmetry between the two groups (t test for independent samples; p = 0.48, two-tailed). CONCLUSION: This study's findings provide a foundation for qualitative symmetry assessment in BRS using automatized digital anthropometry. In the present trial, no difference in the outcomes' optical symmetry was detected between autologous and alloplastic approaches. Level of evidence Level IV. LEVEL OF EVIDENCE IV: This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .


Subject(s)
Breast Neoplasms , Mammaplasty , Breast Neoplasms/diagnostic imaging , Breast Neoplasms/surgery , Cohort Studies , Esthetics , Humans , Mastectomy , Retrospective Studies , Risk Assessment , Treatment Outcome
8.
Quant Imaging Med Surg ; 10(2): 340-355, 2020 Feb.
Article in English | MEDLINE | ID: mdl-32190561

ABSTRACT

BACKGROUND: For surgical fixation of bone fractures of the human hand, so-called Kirschner-wires (K-wires) are drilled through bone fragments. Due to the minimally invasive drilling procedures without a view of risk structures like vessels and nerves, a thorough training of young surgeons is necessary. For the development of a virtual reality (VR) based training system, a three-dimensional (3D) printed phantom hand is required. To ensure an intuitive operation, this phantom hand has to be realistic in both, its position relative to the driller as well as in its haptic features. The softest 3D printing material available on the market, however, is too hard to imitate human soft tissue. Therefore, a support-material (SUP) filled metamaterial is used to soften the raw material. Realistic haptic features are important to palpate protrusions of the bone to determine the drilling starting point and angle. An optical real-time tracking is used to transfer position and rotation to the training system. METHODS: A metamaterial already developed in previous work is further improved by use of a new unit cell. Thus, the amount of SUP within the volume can be increased and the tissue is softened further. In addition, the human anatomy is transferred to the entire hand model. A subcutaneous fat layer and penetration of air through pores into the volume simulate shiftability of skin layers. For optical tracking, a rotationally symmetrical marker attached to the phantom hand with corresponding reference marker is developed. In order to ensure trouble-free position transmission, various types of marker point applications are tested. RESULTS: Several cuboid and forearm sample prints lead to a final 30 centimeter long hand model. The whole haptic phantom could be printed faultless within about 17 hours. The metamaterial consisting of the new unit cell results in an increased SUP share of 4.32%. Validated by an expert surgeon study, this allows in combination with a displacement of the uppermost skin layer a good palpability of the bones. Tracking of the hand marker in dodecahedron design works trouble-free in conjunction with a reference marker attached to the worktop of the training system. CONCLUSIONS: In this work, an optically tracked and haptically correct phantom hand was developed using dual-material 3D printing, which can be easily integrated into a surgical training system.

9.
Quant Imaging Med Surg ; 9(1): 30-42, 2019 Jan.
Article in English | MEDLINE | ID: mdl-30788244

ABSTRACT

BACKGROUND: Currently, it is common practice to use three-dimensional (3D) printers not only for rapid prototyping in the industry, but also in the medical area to create medical applications for training inexperienced surgeons. In a clinical training simulator for minimally invasive bone drilling to fix hand fractures with Kirschner-wires (K-wires), a 3D-printed hand phantom must not only be geometrically but also haptically correct. Due to a limited view during an operation, surgeons need to perfectly localize underlying risk structures only by feeling of specific bony protrusions of the human hand. METHODS: The goal of this experiment is to imitate human soft tissue with its haptic and elasticity for a realistic hand phantom fabrication, using only a dual-material 3D printer and support-material-filled metamaterial between skin and bone. We present our workflow to generate lattice structures between hard bone and soft skin with iterative cube edge (CE) or cube face (CF) unit cells. Cuboid and finger shaped sample prints with and without inner hard bone in different lattice thickness are constructed and 3D printed. RESULTS: The most elastic available rubber-like material is too firm to imitate soft tissue. By reducing the amount of rubber in the inner volume through support material (SUP), objects become significantly softer. Without metamaterial, after disintegration, the SUP can be shifted through the volume and thus the body loses its original shape. Although the CE design increases the elasticity, it cannot restore the fabric form. In contrast to CE, the CF design increases not only the elasticity but also guarantees a local limitation of the SUP. Therefore, the body retains its shape and internal bones remain in its intended place. Various unit cell sizes, lattice thickening and skin thickness regulate the rubber material and SUP ratio. Test prints with higher SUP and lower rubber material percentage appear softer and vice versa. This was confirmed by an expert surgeon evaluation. Subjects adjudged pure rubber-like material as too firm and samples only filled with SUP or lattice structure in CE design as not suitable for imitating tissue. 3D-printed finger samples in CF design were rated as realistic compared to the haptic of human tissue with a good palpable bone structure. CONCLUSIONS: We developed a new dual-material 3D print technique to imitate soft tissue of the human hand with its haptic properties. Blowy SUP is trapped within a lattice structure to soften rubber-like 3D print material, which makes it possible to reproduce a realistic replica of human hand soft tissue.