Strategies Trauma Limb Reconstr ; 9(2): 97-100, 2014 Aug.
Article in English | MEDLINE | ID: mdl-24634195

ABSTRACT

Limb lengthening by callus distraction is commonly performed with the use of external fixation. Lengthening is routinely performed by the patient through small increments throughout the course of a day. Ilizarov has shown that both the rate and frequency of distraction are important factors in the quality of osteogenesis. We report the effect of motorized high frequency distraction for tibial lengthening in comparison with manual low-frequency distraction at the same rate. Manual distraction (0.25 mm four times a day) in a group containing 43 tibiae was compared with motorized distraction (1/1,440 mm 1,400 times a day) in a group containing 27 tibiae. There was no significant difference in time to union or in the incidence of complications.