1.
Crit Care ; 20: 263, 2016 Aug 20.
Article in English | MEDLINE | ID: mdl-27542352

ABSTRACT

BACKGROUND: The design complexity of critical care ventilators (CCVs) can lead to use errors and patient harm. In this study, we present the results of a comparison of four CCVs from market leaders, using a rigorous methodology for the evaluation of use safety and user experience of medical devices. METHODS: We carried out a comparative usability study of four CCVs: Hamilton G5, Puritan Bennett 980, Maquet SERVO-U, and Dräger Evita V500. Forty-eight critical care respiratory therapists participated in this fully counterbalanced, repeated measures study. Participants completed seven clinical scenarios composed of 16 tasks on each ventilator. Use safety was measured by percentage of tasks with use errors or close calls (UE/CCs). User experience was measured by system usability and workload metrics, using the Post-Study System Usability Questionnaire (PSSUQ) and the National Aeronautics and Space Administration Task Load Index (NASA-TLX). RESULTS: Nine of 18 post hoc contrasts between pairs of ventilators were significant after Bonferroni correction, with effect sizes between 0.4 and 1.09 (Cohen's d). There were significantly fewer UE/CCs with SERVO-U when compared to G5 (p = 0.044) and V500 (p = 0.020). Participants reported higher system usability for G5 when compared to PB980 (p = 0.035) and higher system usability for SERVO-U when compared to G5 (p < 0.001), PB980 (p < 0.001), and V500 (p < 0.001). Participants reported lower workload for G5 when compared to PB980 (p < 0.001) and lower workload for SERVO-U when compared to PB980 (p < 0.001) and V500 (p < 0.001). G5 scored better on two of nine possible comparisons; SERVO-U scored better on seven of nine possible comparisons. Aspects influencing participants' performance and perception include the low sensitivity of G5's touchscreen and the positive effect from the quality of SERVO-U's user interface design. CONCLUSIONS: This study provides empirical evidence of how four ventilators from market leaders compare and highlights the importance of medical technology design. Within the boundaries of this study, we can infer that SERVO-U demonstrated the highest levels of use safety and user experience, followed by G5. Based on qualitative data, differences in outcomes could be explained by interaction design, quality of hardware components used in manufacturing, and influence of consumer product technology on users' expectations.


Subject(s)
Equipment Design/standards , Health Personnel/psychology , Patient Safety/standards , Ventilators, Mechanical/statistics & numerical data , Critical Care/methods , Critical Care/standards , Humans , Intensive Care Units/organization & administration , Respiration, Artificial/instrumentation
2.
JMIR Hum Factors ; 3(1): e12, 2016 Mar 24.
Article in English | MEDLINE | ID: mdl-27025912

ABSTRACT

BACKGROUND: We describe the development and evaluation of a secure Web-based system for the purpose of collaborative care called Loop. Loop assembles the team of care with the patient as an integral member of the team in a secure space. OBJECTIVE: The objectives of this paper are to present the iterative design of the separate views for health care providers (HCPs) within each patient's secure space and examine patients', caregivers', and HCPs' perspectives on this separate view for HCP-only communication. METHODS: The overall research program includes cycles of ethnography, prototyping, usability testing, and pilot testing. This paper describes the usability testing phase that directly informed development. A descriptive qualitative approach was used to analyze participant perspectives that emerged during usability testing. RESULTS: During usability testing, we sampled 89 participants from three user groups: 23 patients, 19 caregivers, and 47 HCPs. Almost all perspectives from the three user groups supported the need for an HCP-only communication view. In an earlier prototype, the visual presentation caused confusion among HCPs when reading and composing messages about whether a message was visible to the patient. Usability testing guided us to design a more deliberate distinction between posting in the Patient and Team view and the Health Care Provider Only view at the time of composing a message, which once posted is distinguished by an icon. CONCLUSIONS: The team made a decision to incorporate an HCP-only communication view based on findings during earlier phases of work. During usability testing we tested the separate communication views, and all groups supported this partition. We spent considerable effort designing the partition; however, preliminary findings from the next phase of evaluation, pilot testing, show that the Patient and Team communication is predominantly being used. This demonstrates the importance of a subsequent phase of the clinical trial of Loop to validate the concept and design.

SELECTION OF CITATIONS
SEARCH DETAIL
...