Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Int J Sports Phys Ther ; 17(2): 228-236, 2022.
Article in English | MEDLINE | ID: mdl-35136692

ABSTRACT

BACKGROUND: Measures of postural stability are useful in assisting the diagnosing and managing of athlete concussion. Error counting using the Balance Error Scoring System (BESS) is the clinical standard, but has notable limitations. New technologies offer the potential to increase precision and optimize testing protocols; however, whether these devices enhance clinical assessment remains unclear. PURPOSE: To examine the relationships between metrics of balance performance using different measurement systems in uninjured, healthy collegiate athletes. STUDY DESIGN: Cross-sectional. METHODS: Five hundred and thirty uninjured collegiate athletes were tested using the C3Logix app, which computes ellipsoid volume as a measure of postural stability during the six standard BESS conditions, while concurrently, errors were manually counted during each condition per standard BESS protocols. The association between concurrently measured ellipsoid volumes and error counts were examined with Spearman's correlations. From this sample, 177 participants also performed two double-leg conditions on the Biodex BioSway force plate system on the same day. This system computes Sway Index as a measure of postural stability. The association of ellipsoid volume (C3Logix) and Sway Index (Biodex) was examined with Spearman's correlations. Individual-level data were plotted to visually depict the relationships. RESULTS: C3Logix ellipsoid volume and concurrently recorded error counts were significantly correlated in five of the six BESS conditions (rs:.22-.62; p< 0.0001). C3Logix ellipsoid volume and Biodex Sway Index were significantly correlated in both conditions (rs=.22-.27, p< 0.004). However, substantial variability was shown in postural stability across all three measurement approaches. CONCLUSION: Modest correlation coefficients between simultaneous and same-day balance assessments in uninjured collegiate athletes suggest a need to further optimize clinical protocols for concussion diagnosis. LEVEL OF EVIDENCE: 2b.

2.
Appl Neuropsychol Adult ; : 1-7, 2021 Nov 25.
Article in English | MEDLINE | ID: mdl-34822256

ABSTRACT

Digital neuropsychological test batteries are popular in college athletics; however, well-validated digital tests that are short and portable are needed to expand the feasibility of performing cognitive testing quickly, reliably, and outside standard clinical settings. This study assessed performance on digital versions of Trail Making Test (dTMT) and a modified Symbol Digit Modalities Test (dSDMT) in uninjured collegiate athletes (n = 537; 47% female) using the C3Logix baseline assessment module. Time to complete (dTMT) and the number of correct responses (dSDMT) were computed, transformed into z scores, and compared to age-matched normative data from analogous paper-and-pencil tests. Overall sample performance was compared to normative sample performance using Cohen's d. Sample averages on the dTMT, Part A, and dSDMT were similar to published norms; 97 and 92% of z scores fell within 2 standard deviations of normative means, respectively. The sample averaged faster completion times on dTMT, Part B than published norms, although 98% of z scores were within 2 standard deviations of the normative means. Brief, digitized tests may be useful in populations and testing environments when longer cognitive test batteries are impractical. Future studies should assess the ability of these tests to detect clinically relevant changes following a suspected head injury.

3.
Int J Sports Phys Ther ; 16(1): 126-133, 2021 Feb 01.
Article in English | MEDLINE | ID: mdl-33604142

ABSTRACT

BACKGROUND: Individualized baseline testing is resource and time intensive. The use of normative data to approximate changes after a suspected concussion is thus an appealing alternative. Yet, few peer-reviewed, large-sample studies are available from which to develop accurate normative averages of balance using force-plate technology. PURPOSE: This study sought to validate a normative dataset from the force-plate manufacturer and examine the magnitude and nature of sample variability. STUDY DESIGN: Cross-sectional. METHODS: Baseline balance and self-reported sex, sport, and concussion history were assessed in 533 prospective collegiate athletes (45% female) during pre-participation physical examinations. Balance was measured using four stances from the modified Clinical Test of Sensory Interaction and Balance and quantified as Sway Index Scores with the Biodex Biosway Portable Balance System. Group averages are contrasted to data from the force-plate manufacturer. Individual variability around these averages was visualized and analyzed by sex and sport. RESULTS: Male student athletes showed significantly more sway in the eyes open, soft stance condition than female athletes. These differences were maintained when concussion history was included as a covariate. Athletes, particularly male athletes, in the high versus low contact sport group showed significantly more sway in the eyes open, soft surface and the eyes closed, hard and soft surface stances. CONCLUSION: There was substantial individual variability that was partially explained by sex differences and sport differences. The development of normative averages for sway may benefit from consideration of sex and sport. Further studies should characterize other factors that influence baseline balance in collegiate athletes. LEVEL OF EVIDENCE: 2b.

SELECTION OF CITATIONS
SEARCH DETAIL
...