Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
1.
Eur J Heart Fail ; 25(2): 313-318, 2023 02.
Article in English | MEDLINE | ID: mdl-36097844

ABSTRACT

AIMS: To prospectively evaluate the incidence of myocardial injury after the administration of the fourth dose BNT162b2 mRNA vaccine (Pfizer-BioNTech) against COVID-19. METHODS AND RESULTS: Health care workers who received the BNT162b2 vaccine during the fourth dose campaign had blood samples collected for high-sensitivity cardiac troponin (hs-cTn) during vaccine administration and 2-4 days afterward. Vaccine-related myocardial injury was defined as hs-cTn elevation above the 99th percentile upper reference limit and >50% increase from baseline measurement. Participants with evidence of myocardial injury underwent assessment for possible myocarditis. Of 324 participants, 192 (59.2%) were female and the mean age was 51.8 ± 15.0 years. Twenty-one (6.5%) participants had prior COVID-19 infection, the mean number of prior vaccine doses was 2.9 ± 0.4, and the median time from the last dose was 147 (142-157) days. Reported vaccine-related adverse reactions included local pain at injection site in 57 (17.59%), fatigue in 39 (12.04%), myalgia in 32 (9.88%), sore throat in 21 (6.48%), headache in 18 (5.5%), fever ≥38°C in 16 (4.94%), chest pain in 12 (3.7%), palpitations in 7 (2.16%), and shortness of breath in one (0.3%) participant. Vaccine-related myocardial injury was demonstrated in two (0.62%) participants, one had mild symptoms and one was asymptomatic; both had a normal electrocardiogram and echocardiography. CONCLUSION: In a prospective investigation, an increase in serum troponin levels was documented among 0.62% of healthy health care workers receiving the fourth dose BNT162b2 vaccine. The two cases had mild or no symptoms and no clinical sequela. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT05308680.


Subject(s)
COVID-19 , Heart Failure , Adult , Aged , Female , Humans , Male , Middle Aged , BNT162 Vaccine , COVID-19/prevention & control , Prospective Studies , Vaccination , COVID-19 Vaccines/adverse effects
2.
JACC Case Rep ; 4(13): 819-821, 2022 Jul 06.
Article in English | MEDLINE | ID: mdl-35818595

ABSTRACT

Left ventricular assist devices are increasingly used in patients with advanced heart failure. Gross and histologic evaluation of myocardial apical core specimens, extracted during device placement, can provide important insights. Herein, we describe a case of hydrophilic polymer embolization with associated foreign-body giant cell reaction discovered during apical core evaluation. (Level of Difficulty: Advanced.).

3.
J Card Fail ; 28(6): 963-972, 2022 06.
Article in English | MEDLINE | ID: mdl-35041933

ABSTRACT

OBJECTIVE: Patients with heart failure (HF) are at an increased risk of hospital admissions. The aim of this report is to describe the feasibility, safety and accuracy of a novel wireless left atrial pressure (LAP) monitoring system in patients with HF. METHODS: The V-LAP Left Atrium Monitoring systEm for Patients With Chronic sysTOlic & Diastolic Congestive heart Failure (VECTOR-HF) study is a prospective, multicenter, single-arm, open-label, first-in human clinical trial to assess the safety, performance and usability of the V-LAP system (Vectorious Medical Technologies) in patients with New York Heart Association class III HF. The device was implanted in the interatrial septum via a percutaneous, trans-septal approach guided by fluoroscopy and echocardiography. Primary endpoints included the successful deployment of the implant, the ability to perform initial pressure measurements and safety outcomes. RESULTS: To date, 24 patients have received implants of the LAP-monitoring device. No device-related complications have occurred. LAP was reported accurately, agreeing well with wedge pressure at 3 months (Lin concordance correlation coefficient = 0.850). After 6 months, New York Heart Association class improved in 40% of the patients (95% CI = 16.4%-63.5%), while the 6-minute walk test distance had not changed significantly (313.9 ± 144.9 vs 232.5 ± 129.9 meters; P = 0.076). CONCLUSION: The V-LAP left atrium monitoring system appears to be safe and accurate.


Subject(s)
Atrial Pressure , Heart Failure , Cardiac Catheterization , Humans , Prospective Studies , Stroke Volume
4.
Int J Cardiol ; 296: 71-75, 2019 12 01.
Article in English | MEDLINE | ID: mdl-31327517

ABSTRACT

AIMS: Patients with left ventricular dysfunction (LVD) and prolonged QRS on surface electrocardiogram are at increased risk for heart failure and death and may benefit from resynchronization therapy. Patients with initial narrow QRS may prolong their QRS during the disease course. The occurrence of delayed QRS prolongation, its predictors and associated risk of heart failure hospitalizations (HFH) or death are currently unknown and the subject of this investigation. METHODS & RESULTS: Patients with LVD, QRS < 120 ms and available follow-up ECGs were retrospectively evaluated for persistent unprovoked QRS prolongation >130 ms. Impact on mortality or HFH was assessed using Cox regression with QRS > 130 ms as a time dependent covariate. Following 178 patients for 30 (10;59) median (IQR) months, 28 (16%) patients prolonged their QRS to >130 ms, reaching a QRS duration of 154 ±â€¯29 ms; LBBB pattern was diagnosed among 14 (50%) patients. Patients with delayed QRS prolongation were older (71.9 ±â€¯11.8 vs 64.4 ±â€¯15.1 years p = 0.014), had larger left ventricle and left atrial diameters (6.3 ±â€¯0.9 vs 5.7 ±â€¯0.9 cm p = 0.010; 4.9 ±â€¯0.6 vs 4.5 ±â€¯0.7 cm p = 0.006, respectively) and wider baseline QRS (104.8 ±â€¯12.6 vs 91.4 ±â€¯14.5 ms p < 0.001) which was linearly associated with late QRS prolongation (p for trend<0.0001). In a multivariable model, age, baseline QRS width and left atrial diameter were significantly associated with delayed QRS prolongation. QRS prolongation at follow-up was independently associated with risk of death or HFH (HR 7.426, 95% CI3.017-18.280, p < 0.0001). CONCLUSION: QRS prolongation occurs in a significant proportion of patients with LVD and portends adverse outcome. Advanced age, prolonged QRS and larger left atria are potential predictors. Routine monitoring is justified and physicians may choose to plan ahead for resynchronization therapy in patients at risk for QRS prolongation.


Subject(s)
Electrocardiography , Ventricular Dysfunction, Left/physiopathology , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Retrospective Studies , Time Factors
5.
Am J Med ; 130(11): 1272-1279, 2017 11.
Article in English | MEDLINE | ID: mdl-28552430

ABSTRACT

INTRODUCTION: Pulmonary hypertension has many causes. While it is conventionally thought that the most prevalent is left heart disease, little information about its proportion, causes, and implications on outcome is available. METHODS: Between 1993 and 2015, 12,115 of 66,949 (18%) first adult transthoracic echocardiograms were found to have tricuspid incompetence gradient ≥40 mm Hg, a pulmonary hypertension surrogate. Left heart disease was identified in 8306 (69%) and included valve malfunction in 4115 (49%), left ventricular systolic dysfunction in 2557 (31%), and diastolic dysfunction in 1776 (21%). Patients with left heart disease, as compared with those without left heart disease, were of similar age, fewer were females (50% vs 63% P <.0001), and they had higher tricuspid incompetence gradient (median 48 mm Hg [interquartile range 43, 55] vs 46 mm Hg [42, 54] P <.0001). In reviewing trends over 20 years, the relative proportions of systolic dysfunction decreased and diastolic dysfunction increased (P for trend <.001), while valve malfunction remained the most prevalent cause of pulmonary hypertension with left heart disease. Independent predictors of mortality were age (hazard ratio [HR] 1.05; 95% CI, 1.04-1.05; P <.0001), tricuspid incompetence gradient (HR 1.02; 95% CI, 1.01-1.02, P <.0001 per mm Hg increase), and female sex (HR 0.87; 95% CI, 0.83-0.91, P <.0001). RESULTS: Overall, left heart disease was not an independent risk factor for mortality (HR 1.04; 95% CI, 0.99-1.09; P = .110), but patients with left ventricular systolic dysfunction and with combined systolic dysfunction and valve malfunction had increased mortality compared with patients with pulmonary hypertension but without left heart disease (HR 1.30; 95% CI, 1.20-1.42 and HR 1.44; 95% CI, 1.33-1.55, respectively; P <.0001 for both). CONCLUSIONS: Pulmonary hypertension was found to be associated with left heart disease in 69% of patients. Among these patients, valve malfunction and diastolic dysfunction emerged as prominent causes. Left ventricular dysfunction carries additional risk to patients with pulmonary hypertension.


Subject(s)
Echocardiography , Hypertension, Pulmonary , Tricuspid Valve Insufficiency , Ventricular Dysfunction, Left , Aged , Aged, 80 and over , Echocardiography/methods , Echocardiography/statistics & numerical data , Female , Hemodynamics , Humans , Hypertension, Pulmonary/diagnosis , Hypertension, Pulmonary/etiology , Hypertension, Pulmonary/mortality , Hypertension, Pulmonary/physiopathology , Israel/epidemiology , Male , Middle Aged , Mortality , Outcome Assessment, Health Care , Prevalence , Retrospective Studies , Risk Assessment/methods , Risk Factors , Tricuspid Valve Insufficiency/diagnosis , Tricuspid Valve Insufficiency/physiopathology , Ventricular Dysfunction, Left/complications , Ventricular Dysfunction, Left/diagnosis , Ventricular Dysfunction, Left/epidemiology , Ventricular Dysfunction, Left/physiopathology
SELECTION OF CITATIONS
SEARCH DETAIL
...