1.
Guang Pu Xue Yu Guang Pu Fen Xi ; 36(3): 624-30, 2016 Mar.
Article in Chinese | MEDLINE | ID: mdl-27400494

ABSTRACT

Compared with traditional sampling-based sensing method, absorption spectroscopy technology is well suitable for detonation flow diagnostics, since it can provide with us fast response, nonintrusive, sensitive solution for situ measurements of multiple flow-field parameters. The temperature and concentration test results are the average values along the laser path with traditional absorption spectroscopy technology, while the boundary of detonation flow external field is unknown and it changes all the time during the detonation engine works, traditional absorption spectroscopy technology is no longer suitable for detonation diagnostics. The trend of line strength with temperature varies with different absorption lines. By increasing the number of absorption lines in the test path, more information of the non-uniform flow field can be obtained. In this paper, based on multispectral absorption technology, the reconstructed model of detonation flow external field distribution was established according to the simulation results of space-time conservation element and solution element method, and a diagnostic method of detonation flow external field was given. The model deviation and calculation error of the least squares method adopted were studied by simulation, and the maximum concentration and temperature calculation error was 20.1% and 3.2%, respectively. Four absorption lines of H2O were chosen and detonation flow was scanned at the same time. The detonation external flow testing system was set up for the valveless gas-liquid continuous pulse detonation engine with the diameter of 80 mm. Through scanning H2O absorption lines with a high frequency of 10 kHz, the on-line detection of detonation external flow was realized by direct absorption method combined with time-division multiplexing technology, and the reconstruction of dynamic temperature distribution was realized as well for the first time, both verifying the feasibility of the test method. The test results show that both of the temperature and H2O concentration rose with the arrival of detonation wave. With the increase of the vertical distance between the detonation tube nozzle and the laser path, the time of temperature and concentration coming to the peak delayed, and the temperature variation trend tended to slow down. At 20 cm from detonation tube nozzle, the maximum temperature hit 1 329 K and the maximum H2O concentration of 0.19 occurred at 4 ms after ignition. The research can provide with us the support for expanding the detonation test field with absorption spectroscopy technology, and can also help to promote the detonation mechanism research and to enhance the level of detonation engine control technology.

2.
Guang Pu Xue Yu Guang Pu Fen Xi ; 34(3): 582-6, 2014 Mar.
Article in Chinese | MEDLINE | ID: mdl-25208369

ABSTRACT

The effect detection of detonation exhaust can provide measurement data for exploring the formation mechanism of detonation, the promotion of detonation efficiency and the reduction of fuel waste. Based on tunable diode laser absorption spectroscopy technique combined with double optical path cross-correlation algorithm, the article raises the diagnosis method to realize the on-line testing of detonation exhaust velocity, temperature and H2O gas concentration. The double optical path testing system is designed and set up for the valveless pulse detonation engine with the diameter of 80 mm. By scanning H2O absorption lines of 1343nm with a high frequency of 50 kHz, the on-line detection of gas-liquid pulse detonation exhaust is realized. The results show that the optical testing system based on tunable diode laser absorption spectroscopy technique can capture the detailed characteristics of pulse detonation exhaust in the transient process of detonation. The duration of single detonation is 85 ms under laboratory conditions, among which supersonic injection time is 5.7 ms and subsonic injection time is 19.3 ms. The valveless pulse detonation engine used can work under frequency of 11 Hz. The velocity of detonation overflowing the detonation tube is 1,172 m x s(-1), the maximum temperature of detonation exhaust near the nozzle is 2 412 K. There is a transitory platform in the velocity curve as well as the temperature curve. H2O gas concentration changes between 0-7% during detonation under experimental conditions. The research can provide measurement data for the detonation process diagnosis and analysis, which is of significance to advance the detonation mechanism research and promote the research of pulse detonation engine control technology.

3.
Guang Pu Xue Yu Guang Pu Fen Xi ; 32(5): 1329-33, 2012 May.
Article in Chinese | MEDLINE | ID: mdl-22827083

ABSTRACT

Tunable diode laser absorption spectroscopy (TDLAS) technology is a kind of high sensitivity, high selectivity of non contacting gas in situ measurement technique. In the present paper, in situ gas temperature measurement of an open environment was achieved by means of direct scanning multiple characteristic lines of H2O and combined with least-squares algorithm. Through the use of HITRAN spectral database, the boundary effect on the gas temperature and concentration measurements was discussed in detail, and results showed that the combination of scanning multiple characteristic lines and least-squares algorithm can effectively reduce the boundary effect on the gas temperature measurements under the open environment. Experiments using time division multiplexing technology to simultaneously scan 7444.36, 7185.60, 7182.95 and 7447.48 cm(-1), the four characteristic H2O lines, the gas temperature of tubular furnace in the range of 573-973 K was measured under different conditions. The maximum temperature difference between absorption spectrum measurement and thermocouple signal was less than 52.4 K, and the maximum relative error of temperature measurement was 6.8%.