Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Publication year range
1.
Preprint in English | medRxiv | ID: ppmedrxiv-20187179

ABSTRACT

ObjectivesCOVID-19 has caused a large global pandemic. Patients with COVID-19 exhibited considerable variation in disease behavior. Pervious genome-wide association studies have identified potential genetic variants involved in the risk and prognosis of COVID-19, but the underlying biological interpretation remains largely unclear. MethodsWe applied the summary data-based Mendelian randomization (SMR) method to identify genes that were pleiotropically associated with the risk and various outcomes of COVID-19, including severe respiratory confirmed COVID-19 and hospitalized COVID-19. ResultsIn blood, we identified 2 probes, ILMN_1765146 and ILMN_1791057 tagging IFNAR2, that showed pleiotropic association with hospitalized COVID-19 ({beta} [SE] = 0.42 [0.09], P = 4.75x10-06 and {beta} [SE] = -0.48 [0.11], P = 6.76x10-06, respectively). Although no other probes were significant after correction for multiple testing in both blood and lung, multiple genes as tagged by the top 5 probes were involved in inflammation or antiviral immunity, and several other tagged genes, such as PON2 and HPS5, were involved in blood coagulation. ConclusionsWe identified IFNAR2 and other potential genes that could be involved in the susceptibility or prognosis of COVID-19. These findings provide important leads to a better understanding of the mechanisms of cytokine storm and venous thromboembolism in COVID-19 and potential therapeutic targets for the effective treatment of COVID-19.

2.
China Pharmacy ; (12): 1975-1980, 2019.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-817217

ABSTRACT

OBJECTIVE: To establish a method for simultaneous determination of 8 non-anthraquinone constituents in Rheum palmatum. METHODS: HPLC method was adopted. The determination was performed on Symmetry C18 column with mobile phase consisted of methanol-0.1% phosphoric acid (gradient elution) at the flow rate of 1.0 mL/min. The column temperature was 30 ℃ and detection wavelength was 280 nm. Sample size was 30 μL. RESULTS: The linear range of gallic acid, catechin, epicatechin, resveratrol 4′-O-glucopyranoside, epicatechin gallate, resveratrol 4′-O-β-D-(6″-O-galloyl)-glucopyranoside, sennoside A, 4′-hydroxyphenyl-2-butanone-4′-O-β-D-(2″-O-galloyl-6″-O-p-hydroxy cinnamyl)-glucopyranoside were 6.16-2 464 ng(r=0.999 9), 37.4-14 960 ng(r=0.999 9), 7.635-3 054 ng(r=0.999 7), 7.63-3 052 ng(r=0.999 9), 8.32-3 328 ng(r=0.999 9), 11.5-4 600 ng(r=0.999 9), 16.08-6 432 ng(r=0.999 9), 29.3-11 720 ng(r=0.999 9), respectively. The limits of quantitation were 3.48, 4.30, 6.40, 4.40, 3.39, 2.87, 8.40 and 4.95 ng, respectively. The limits of detection were 2.32, 2.58, 2.40, 2.64, 2.26, 1.23, 4.20, 2.97 ng, respectively. RSDs of precision, stability and reproducibility tests were all lower than 5%. Recoveries were 94.32%- 100.54%(RSD=2.78%,n=6), 91.15%-99.36%(RSD=3.72%,n=6), 92.16%-98.04%(RSD=2.39%,n=6), 93.41%-100.73%(RSD=3.17%,n=6), 93.89%-98.40%(RSD=1.99%,n=6), 92.61%-101.74%(RSD=3.71%,n=6), 92.66%-103.40%(RSD=3.76%,n=6), 95.45%-102.70%(RSD=3.06%,n=6), respectively. CONCLUSIONS: The established method is simple, accurate and specific, and can be used for the simultaneous determination of 8 non-anthraquinone constituents in R. palmatum.

3.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-559560

ABSTRACT

Objective To develop the quality standard for Lajiao Fengshi Plaster. Methods Identification for menthol and borneol were established by gas chromatography SP-2000A. The content of capsaicin, an activity component from capsicum which is the main ingredient of Lajiao Fengshi Plaster, was determined by Kromasil C18 chromatogram columniations(250 mm?4.6 mm, 5 ?m)mobile phase of aqueous acetonitrile-0.17%phosphoric with gradient elution method, velocity of flow: 1.0 ml/min, and detection wavelength: 209 nm. Results The retention time of menthol and borneol is consistent with that of the main ingredient of the reference substance. The good liner range of capsaicin reference substance on calibration curve was 0.03952~0.3952 ?g (r=0.9995), and the average recovery was 96.61%, RSD=0.30%. Conclusion The method is sensitive, specific, and repeatable. It could be used in quality control for Lajiao Fengshi Plaster.

SELECTION OF CITATIONS
SEARCH DETAIL
...