1.
Ned Tijdschr Geneeskd ; 1632019 07 04.
Article in Dutch | MEDLINE | ID: mdl-31283124

ABSTRACT

Portable dialysis devices enable dialysis patients to dialyse at home, thereby enhancing their mobility and autonomy. The development of a strategy to facilitate re-use of dialysate is crucial in the deployment of these devices. In the Netherlands, clinical trials are currently prepared involving a 10 kg portable haemodialysis device and a 10 kg portable system for continuous flow peritoneal dialysis, respectively.


Subject(s)
Kidney Failure, Chronic/therapy , Kidneys, Artificial , Renal Dialysis/instrumentation , Wearable Electronic Devices , Home Care Services , Humans , Netherlands , Peritoneal Dialysis/instrumentation
2.
Am J Physiol Renal Physiol ; 315(5): F1385-F1397, 2018 11 01.
Article in English | MEDLINE | ID: mdl-29993277

ABSTRACT

The key to success in developing a wearable dialysis device is a technique to safely and efficiently regenerate and reuse a small volume of dialysate in a closed-loop system. In a hemodialysis model in goats, we explored whether urea removal by electro-oxidation (EO) could be effectively and safely applied in vivo. A miniature dialysis device was built, containing 1 or 2 "EO units," each with 10 graphite electrodes, with a cumulative electrode surface of 585 cm2 per unit. The units also contained poly(styrene-divinylbenzene) sulfonate beads, FeOOH beads, and activated carbon for respective potassium, phosphate, and chlorine removal. Urea, potassium, and phosphate were infused to create "uremic" conditions. Urea removal was dependent on total electrode surface area [removal of 8 mmol/h (SD 1) and 16 mmol/h (SD 2) and clearance of 12 ml/min (SD 1) and 20 ml/min (SD 3) with 1 and 2 EO units, respectively] and plasma urea concentration but not on flow rate. Extrapolating urea removal with 2 EO units to 24 h would suffice to remove daily urea production, but for intermittent dialysis, additional units would be required. EO had practically no effects on potassium and phosphate removal or electrolyte balance. However, slight ammonium releasewas observed, and some chlorine release at higher dialysate flow rates. Minor effects on acid-base balance were observed, possibly partly due to infusion of chloride. Mild hemolysis occurred, which seemed related to urea infusion. In conclusion, clinically relevant urea removal was achieved in vivo by electro-oxidation. Efficacy and safety testing in a large-animal model with uremia is now indicated.


Subject(s)
Dialysis Solutions/metabolism , Renal Dialysis/instrumentation , Urea/blood , Uremia/therapy , Wearable Electronic Devices , Acid-Base Equilibrium , Acid-Base Imbalance/etiology , Acid-Base Imbalance/physiopathology , Animals , Creatinine/blood , Disease Models, Animal , Equipment Design , Goats , Hemolysis , Miniaturization , Models, Biological , Oxidation-Reduction , Phosphates/blood , Potassium/blood , Renal Dialysis/adverse effects , Time Factors , Uremia/blood , Uremia/physiopathology , Wakefulness
3.
Expert Rev Med Devices ; 15(5): 323-336, 2018 05.
Article in English | MEDLINE | ID: mdl-29633900

ABSTRACT

INTRODUCTION: Since the advent of peritoneal dialysis (PD) in the 1970s, the principles of dialysis have changed little. In the coming decades, several major breakthroughs are expected. AREAS COVERED: Novel wearable and portable dialysis devices for both hemodialysis (HD) and PD are expected first. The HD devices could facilitate more frequent and longer dialysis outside of the hospital, while improving patient's mobility and autonomy. The PD devices could enhance blood purification and increase technique survival of PD. Further away from clinical application is the bioartificial kidney, containing renal cells. Initially, the bioartificial kidney could be applied for extracorporeal treatment, to partly replace renal tubular endocrine, metabolic, immunoregulatory and secretory functions. Subsequently, intracorporeal treatment may become possible. EXPERT COMMENTARY: Key factors for successful implementation of miniature dialysis devices are patient attitudes and cost-effectiveness. A well-functioning and safe extracorporeal blood circuit is required for HD. For PD, a double lumen PD catheter would optimize performance. Future research should focus on further miniaturization of the urea removal strategy. For the bio-artificial kidney (BAK), cost effectiveness should be determined and a general set of functional requirements should be defined for future studies. For intracorporeal application, water reabsorption will become a major challenge.


Subject(s)
Biomedical Engineering , Kidneys, Artificial , Renal Dialysis , Humans , Miniaturization , Translational Research, Biomedical
4.
Nephrol Dial Transplant ; 32(6): 951-959, 2017 Jun 01.
Article in English | MEDLINE | ID: mdl-27220758

ABSTRACT

BACKGROUND: Patients on standard intermittent haemodialysis suffer from strong fluctuations in plasma potassium and phosphate. Prolonged dialysis with a wearable device, based on continuous regeneration of a small volume of dialysate using ion exchangers, could moderate these fluctuations and offer increased clearance of these electrolytes. We report in vivo results on the efficacy of potassium and phosphate adsorption from a wearable dialysis device. We explore whether equilibration of ion exchangers at physiological Ca 2+ , Mg 2+ and hypotonic NaCl can prevent calcium/magnesium adsorption and net sodium release, respectively. Effects on pH and HCO3- were studied. METHODS: Healthy goats were instrumented with a central venous catheter and dialysed. Potassium and phosphate were infused to achieve plasma concentrations commonly observed in dialysis patients. An adsorption cartridge containing 80 g sodium poly(styrene-divinylbenzene) sulphonate and 40 g iron oxide hydroxide beads for potassium and phosphate removal, respectively, was incorporated in a dialysate circuit. Sorbents were equilibrated and regenerated with a solution containing NaCl, CaCl 2 and MgCl 2 . Blood was pumped over a dialyser and dialysate was recirculated over the adsorption cartridge in a countercurrent direction. RESULTS: Potassium and phosphate adsorption was 7.7 ± 2.7 and 4.9 ± 1.3 mmol in 3 h, respectively. Adsorption capacity remained constant during consecutive dialysis sessions and increased with increasing K + and PO43-. Equilibration at physiological Ca 2+ and Mg 2+ prevented net adsorption, eliminating the need for post-cartridge calcium and magnesium infusion. Equilibration at hypotonic NaCl prevented net sodium release Fe 2+ and arterial pH did not change. Bicarbonate was adsorbed, which could be prevented by equilibrating at HCO3- 15 mM. CONCLUSION: We demonstrate clinically relevant, concentration-dependent, pH-neutral potassium and phosphate removal in vivo with small volumes of regenerable ion exchangers in our prototype wearable dialysis device. Application of the selected ion exchangers for potassium and phosphate removal in a wearable dialysis device appears to be effective with a low-risk profile.


Subject(s)
Phosphates/isolation & purification , Potassium/isolation & purification , Renal Dialysis/instrumentation , Adsorption , Animals , Bicarbonates/blood , Equipment Reuse , Ferric Compounds/chemistry , Goats , Humans , Ion Exchange , Magnesium/blood , Phosphates/blood , Potassium/blood , Quality Improvement , Renal Dialysis/methods , Sodium/chemistry
5.
Artif Organs ; 38(12): 998-1006, 2014 Dec.
Article in English | MEDLINE | ID: mdl-24750025

ABSTRACT

A major challenge for a wearable dialysis device is removal of urea, as urea is difficult to adsorb while daily production is very high. Electro-oxidation (EO) seems attractive because electrodes are durable, small, and inexpensive. We studied the efficacy of urea oxidation, generation of chlorine by-products, and their removal by activated carbon (AC). EO units were designed. Three electrode materials (platinum, ruthenium oxide, and graphite) were compared in single pass experiments using urea in saline solution. Chlorine removal by AC in series with EO by graphite electrodes was tested. Finally, urea-spiked bovine blood was dialyzed and dialysate was recirculated in a dialysate circuit with AC in series with an EO unit containing graphite electrodes. Platinum electrodes degraded more urea (21 ± 2 mmol/h) than ruthenium oxide (13 ± 2 mmol/h) or graphite electrodes (13 ± 1 mmol/h). Chlorine generation was much lower with graphite (13 ± 4 mg/h) than with platinum (231 ± 22 mg/h) or ruthenium oxide electrodes (129 ± 12 mg/h). Platinum and ruthenium oxide electrodes released platinum (4.1 [3.9-8.1] umol/h) and ruthenium (83 [77-107] nmol/h), respectively. AC potently reduced dialysate chlorine levels to < 0.10 mg/L. Urea was removed from blood by EO at constant rate (9.5 ± 1.0 mmol/h). EO by graphite electrodes combined with AC shows promising urea removal and chlorine release complying with Association for the Advancement of Medical Instrumentation standards, and may be worth further exploring for dialysate regeneration in a wearable system.


Subject(s)
Renal Dialysis/instrumentation , Urea/blood , Animals , Cattle , Dialysis Solutions , Electrodes , Oxidation-Reduction
6.
Nephrol Dial Transplant ; 28(9): 2364-71, 2013 Sep.
Article in English | MEDLINE | ID: mdl-23825104

ABSTRACT

BACKGROUND: Continuous dialysis could provide benefit by constant removal of potassium and phosphate. This study investigates the suitability of specific potassium and phosphate sorbents for incorporation in an extracorporeal device by capacity and regenerability testing. METHODS: Capacity testing was performed in uraemic plasma. Regenerability was tested for potassium sorbents, with adsorption based on cationic exchange for sodium, with 0.1 M and 1.0 M NaCl. To regenerate phosphate sorbents, with adsorption based on anionic exchange, 0.1 M and 1.0 M NaHCO3 and NaOH were used. Subsequently, sodium polystyrene divinylbenzene sulphonate (RES-A) and iron oxide hydroxide (FeOOH) beads were incorporated in a cartridge for testing in bovine blood using a recirculating blood circuit and a dialysis circuit separated by a high-flux dialyzer (dynamic setup). Preloading was tested to assess whether this could limit calcium and magnesium adsorption. RESULTS: In the batch-binding assays, zirconium phosphate most potently adsorbed potassium (0.44 ± 0.05 mmol/g) and RES-A was the best regenerable potassium sorbent (92.9 ± 5.7% with 0.1 M NaCl). Zirconium oxide hydroxide (ZIR-hydr) most potently adsorbed phosphate (0.23 ± 0.05 mmol/g) and the polymeric amine sevelamer carbonate was the best regenerable sorbent (85.7 ± 5.2% with 0.1 M NaHCO3). In the dynamic setup, a potassium adsorption of 10.72 ± 2.06 mmol in 3 h was achieved using 111 g of RES-A and a phosphate adsorption of 4.73 ± 0.53 mmol in 3 h using 55 g of FeOOH. Calcium and magnesium preloading was shown to reduce the net adsorption in 3 h from 3.57 ± 0.91 to -0.29 ± 1.85 and 1.02 ± 0.05 to -0.31 ± 0.18 mmol, respectively. CONCLUSION: RES-A and FeOOH are suitable, regenerizable sorbents for potassium and phosphate removal in dialysate regeneration. Use of zirconium carbonate and ZIR-hydr may further increase phosphate adsorption, but may compromise sorbent regenerability. Use of polymeric amines for phosphate adsorption may enhance sorbent regenerability. Calcium and magnesium preloading considerably reduced net adsorption of these ions.


Subject(s)
Ferric Compounds/chemistry , Phosphates/chemistry , Potassium/chemistry , Renal Dialysis/instrumentation , Renal Dialysis/methods , Adsorption , Animals , Cattle , In Vitro Techniques , Oxides/chemistry , Phosphates/blood , Phosphates/isolation & purification , Potassium/blood , Potassium/isolation & purification
7.
Biomaterials ; 34(32): 7819-28, 2013 Oct.
Article in English | MEDLINE | ID: mdl-23876759

ABSTRACT

In end stage renal disease (ESRD) waste solutes accumulate in body fluid. Removal of protein bound solutes using conventional renal replacement therapies is currently very poor while their accumulation is associated with adverse outcomes in ESRD. Here we investigate the application of a hollow fiber mixed matrix membrane (MMM) for removal of these toxins. The MMM hollow fiber consists of porous macro-void free polymeric inner membrane layer well attached to the activated carbon containing outer MMM layer. The new membranes have permeation properties in the ultrafiltration range. Under static conditions, they adsorb 57% p-cresylsulfate, 82% indoxyl sulfate and 94% of hippuric acid from spiked human plasma in 4 h. Under dynamic conditions, they adsorb on average 2.27 mg PCS/g membrane and 3.58 mg IS/g membrane in 4 h in diffusion experiments and 2.68 mg/g membrane PCS and 12.85 mg/g membrane IS in convection experiments. Based on the dynamic experiments we estimate that our membranes would suffice to remove the daily production of these protein bound solutes.


Subject(s)
Membranes, Artificial , Toxins, Biological/blood , Toxins, Biological/isolation & purification , Ultrafiltration/instrumentation , Adsorption , Cresols/blood , Cresols/isolation & purification , Hippurates/blood , Hippurates/isolation & purification , Humans , Indican/blood , Indican/isolation & purification , Microscopy, Electron, Scanning , Sulfuric Acid Esters/blood , Sulfuric Acid Esters/isolation & purification
8.
Ned Tijdschr Geneeskd ; 157(52): A6965, 2013.
Article in Dutch | MEDLINE | ID: mdl-24382046

ABSTRACT

Portable or wearable dialysis devices could increase treatment flexibility and dialysis patients' independence. Current renal replacement therapies such as intermittent haemodialysis extend life but are a burden, are time-consuming and immobilize patients. An additional disadvantage is the discontinuous nature of the treatment. Peritoneal dialysis is a good alternative, but is associated with relatively limited toxin clearance and a need for high glucose concentrations in the dialysate. Portable dialysis devices could be used as a replacement or to support existing dialysis techniques. At the moment several initiatives, including some started in the Netherlands, aim at the development of a portable device. Some of them are so far into development that they are at a preclinical phase, but as yet none has been approved for regular use in patients. To achieve the ultimate goal, an implantable artificial kidney, a lot of hurdles still have to be surmounted.


Subject(s)
Kidney Failure, Chronic/therapy , Kidneys, Artificial , Equipment Design , Forecasting , Hemodialysis Solutions/administration & dosage , Humans , Kidneys, Artificial/trends , Netherlands , Peritoneal Dialysis/instrumentation , Peritoneal Dialysis/methods , Renal Dialysis/instrumentation , Renal Dialysis/methods , Renal Replacement Therapy/instrumentation , Renal Replacement Therapy/methods
9.
Acta Biomater ; 8(6): 2279-87, 2012 Jul.
Article in English | MEDLINE | ID: mdl-22406909

ABSTRACT

Hemodialysis is a commonly used blood purification technique in patients requiring kidney replacement therapy. Sorbents could increase uremic retention solute removal efficiency but, because of poor biocompatibility, their use is often limited to the treatment of patients with acute poisoning. This paper proposes a novel membrane concept for combining diffusion and adsorption of uremic retention solutes in one step: the so-called mixed-matrix membrane (MMM). In this concept, adsorptive particles are incorporated in a macro-porous membrane layer whereas an extra particle-free membrane layer is introduced on the blood-contacting side of the membrane to improve hemocompatibility and prevent particle release. These dual-layer mixed-matrix membranes have high clean-water permeance and high creatinine adsorption from creatinine model solutions. In human plasma, the removal of creatinine and of the protein-bound solute para-aminohippuric acid (PAH) by single and dual-layer membranes is in agreement with the removal achieved by the activated carbon particles alone, showing that under these experimental conditions the accessibility of the particles in the MMM is excellent. This study proves that the combination of diffusion and adsorption in a single step is possible and paves the way for the development of more efficient blood purification devices, excellently combining the advantages of both techniques.


Subject(s)
Blood , Membranes, Artificial , Acute Kidney Injury/blood , Acute Kidney Injury/therapy , Adsorption , Creatinine/blood , Creatinine/isolation & purification , Diffusion , Humans , Microscopy, Electron, Scanning , Renal Dialysis , p-Aminohippuric Acid/blood , p-Aminohippuric Acid/isolation & purification