Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 22
Filter
1.
Eur J Obstet Gynecol Reprod Biol ; 291: 23-28, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37806028

ABSTRACT

OBJECTIVE: Uterine contractions are essential for childbirth, but also for expulsion of the placenta and for limiting postpartum blood loss. Postpartum hemorrhage is associated with almost 25% of the maternal deaths worldwide and the leading cause of maternal death in most low-income countries. Little is known about the physiology of the uterus postpartum, particularly due to the lack of an accurate measurement tool. The primary objective of this pilot study is to explore the potential of using electrohysterography to detect postpartum uterine contractions. If postpartum uterine activity can be objectified, this could contribute to understanding the physiology of the uterus and improve diagnosis and treatment of postpartum hemorrhage. STUDY DESIGN: In this observational study we included women aiming for a vaginal birth in two large maternity clinics in the Netherlands, Amphia Hospital Breda (group A, N2018-0161) and Máxima Medical Center Veldhoven (group B, N17.149). An electrode patch was placed on the maternal abdomen to record real-time electrical uterine activity until one hour postpartum continuously. In group A, the placement of the patch was lower than in group B. For analysis, tracings were divided into five different phases (1: dilatation until start pushing, 2: from start pushing until childbirth, 3: from childbirth until placental expulsion, 4: first hour after placental expulsion and 5: after one hour postpartum). Readability, signal quality and contraction frequency per hour were assessed. Additionally, patient satisfaction was evaluated through a survey. RESULTS: In total 91 pregnant women were included of whom 45 in group A and 46 women in group B. Complete registrations were obtained throughout the five labor phases with very little artefacts or signal loss. The readability of the tracings decreased after childbirth. A significantly better readability was found in tracings where the patch placement was lower on the abdomen for phases 4 and 5. Contraction frequency was highest during phase 2 and decreased towards phase 5. Women rated the satisfaction with electrohysterography as high and mostly did not notice the patch. CONCLUSION: It is possible to detect uterine activity postpartum with electrohysterography. Further investigation is recommended to improve diagnosis and treatment of postpartum hemorrhage.


Subject(s)
Postpartum Hemorrhage , Pregnancy , Female , Humans , Postpartum Hemorrhage/diagnosis , Pilot Projects , Placenta , Uterine Contraction/physiology , Postpartum Period
2.
J Hematol ; 10(5): 228-231, 2021 Oct.
Article in English | MEDLINE | ID: mdl-34804313

ABSTRACT

The widely use of non-invasive prenatal testing (NIPT) may lead to accidental findings and the discovery of malignancy in pregnancy, often in asymptomatic patients. Diagnosis of such subclinical malignancy during pregnancy in the asymptomatic patient poses a predicament for both doctor and patient. The risks and benefits of possible treatment for both mother and child have to be weighted, and there is often limited scientific evidence available. We present a case of an abnormal NIPT result, leading to the diagnosis of acute myeloid leukemia (AML) in an asymptomatic pregnant patient. After multiple multidisciplinary meetings and an elaborate shared decision making (SDM) process, a watch and wait strategy was implemented, in contradiction with general treatment recommendations. Following this approach, it was possible to achieve a near term pregnancy before delivery of a healthy baby girl. The patient could subsequently commence treatment of her AML and is still in complete remission after a follow-up of 25 months. Our case report highlights the possibility of watch and wait strategy in selected cases and the importance of multidisciplinary collaboration and SDM, when faced with the accidental finding of AML through NIPT.

3.
Eur J Obstet Gynecol Reprod Biol ; 259: 178-184, 2021 Apr.
Article in English | MEDLINE | ID: mdl-33684672

ABSTRACT

OBJECTIVE: Electrohysterography is a non-invasive technique to monitor uterine activity and has a significantly higher sensitivity compared to conventional external tocodynamometry. Whether this technique could lead to improved obstetrical outcomes is still unknown. In this propensity score matched study, clinical results of the first pilot implementing electrohysterography during labor were evaluated. The hypothesis tested is that electrohysterography will help to optimize uterine activity and thereby lead to fewer obstetric interventions. Secondary outcomes were Apgar score, arterial umbilical pH values, first stage labor duration, episiotomy rate and postpartum vaginal blood loss. STUDY DESIGN: From November 2017 until October 2018, electrohysterography was introduced as a standard alternative for monitoring uterine activity in high-risk deliveries. It could be applied in case of induced labor, previous cesarean delivery, body mass index ≥30 kg/m2 or an inadequate external tocodynamometry monitoring. Outcomes were compared to a matched group of women in which external tocodynamometry was applied for uterine activity monitoring during labor. These women were identified using propensity scores. RESULTS: A total of 348 women received electrohysterography as standard method of uterine monitoring during labor. A match (1:1 ratio) was found for 317 women, resulting in a total population of 634 women. No significant differences were seen in obstetric interventions (i.e. cesarean deliveries and assisted vaginal deliveries) between the electrohysterography and tocodynamometry group (P = 0.80). No statistically significant differences were seen regarding the secondary outcomes. CONCLUSIONS: This first pilot study implementing electrohysterography as monitoring method during labor in a high-risk population did not result in statistically significant differences regarding obstetric interventions, low Apgar scores or low umbilical artery pH values. Therefore, we suggest that electrohysterography causes no harm and we recommend further implementation and evaluation in clinical practice.


Subject(s)
Labor, Obstetric , Uterine Contraction , Adolescent , Electromyography , Female , Humans , Pilot Projects , Pregnancy , Propensity Score , Research Design
4.
Eur J Obstet Gynecol Reprod Biol ; 255: 142-146, 2020 Dec.
Article in English | MEDLINE | ID: mdl-33129016

ABSTRACT

OBJECTIVE: The aim of this research was to assess the quality and inter- and intra-observer agreement of tracings obtained by three different techniques for uterine contraction monitoring: the external tocodynamometer (TOCO), the intrauterine pressure catheter (IUPC) and a recently introduced method based on electrohysterography (EHG). STUDY DESIGN: We included 150 uterine activity registrations from a previous prospective observational study (W3 study), conducted at Máxima Medical Centre in Veldhoven, the Netherlands. Term singleton pregnant women were simultaneously monitored with TOCO, IUPC and EHG during labor. Six clinicians, blinded to the source (TOCO, IUPC, or EHG) and subject, evaluated all tracings that were subsequently presented in random order. They annotated contractions and assigned each tracing a score for interpretability of 2 (good), 1 (moderate) or 0 (poor). To evaluate inter-observer agreement, we calculated kappa values for the qualitative assessment, and intraclass correlation coefficients (ICC) for the number of contractions annotated by clinicians. Four clinicians repeated this procedure to evaluate intra-observer agreement. RESULTS: IUPC tracings received the highest quality rating, with a mean score of 1.95, followed by a mean score of 1.60 for EHG and 0.80 for TOCO (p < 0.05). Mean weighted kappa values were 0.63 for TOCO and 0.45 for EHG. The average number of contractions that was picked up by clinicians was 59.8 for the intrauterine pressure catheter, 49.8 for EHG and 26.4 for TOCO. The ICC of the intrauterine pressure catheter was significantly higher than the external methods, regarding both inter- and intra-observer agreement (0.98 and 0.99 respectively). CONCLUSION: IUPC recordings scored best regarding quality, inter- and intra-observer agreement. However, due to safety issues, in many countries this technique is not used anymore. The quality of TOCO was rated as poor and many contractions were missed as compared to the gold standard. From a clinical interpretational point of view, EHG is favorable to TOCO. EHG recordings were assigned higher quality scores, but with less agreement between clinicians. An explanation could be that EHG is a relatively new technique, while IUPC and the TOCO are being used for decades. Building experience with EHG (training) is therefore recommended.


Subject(s)
Labor, Obstetric , Uterine Monitoring , Adolescent , Electromyography , Female , Humans , Netherlands , Observer Variation , Pregnancy , Uterine Contraction
5.
Obstet Gynecol Surv ; 75(8): 497-509, 2020 Aug.
Article in English | MEDLINE | ID: mdl-32856716

ABSTRACT

IMPORTANCE: Hypertensive pregnancy disorders (HPDs) are associated with an increased risk of long-term cardiovascular disease. Speckle tracking echocardiography (STE) might be useful in the early detection of preclinical cardiac changes in women with HPDs. OBJECTIVE: The aim of this study was to study whether STE is a suitable method to detect differences in cardiac function in pregnant women with HPD compared with normotensive pregnant women or between women with a history of a pregnancy complicated by HPD compared with women with a history of an uncomplicated pregnancy. EVIDENCE ACQUISITION: The databases Medline, EMBASE, and Central were systematically searched for studies comparing cardiac function measured with STE in pregnant women with HPD or women with a history of HPD and women with a history of normotensive pregnancies. RESULTS: The search identified 16 studies, including 870 women with a history of HPD and 693 normotensive controls. Most studies during pregnancy (n = 12/13) found a decreased LV-GLS (left ventricular global longitudinal strain) in HPD compared with normotensive pregnant controls. LV-GRS (left ventricular global radial strain) and LV-GLCS (left ventricular global circumferential strain) are decreased in women with early-onset and severe preeclampsia. Women with a history of early-onset preeclampsia show lasting myocardial changes, with significantly decreased LV-GLS, LV-GLCS, and LV-GRS. CONCLUSIONS AND RELEVANCE: LV-GLS is significantly decreased in pregnant women with HPD compared with normotensive pregnant women. Other deformation values show a significant decrease in women with severe or early-onset preeclampsia, with lasting myocardial changes after early-onset preeclampsia.


Subject(s)
Echocardiography/methods , Heart Ventricles/diagnostic imaging , Heart Ventricles/pathology , Hypertension, Pregnancy-Induced/diagnostic imaging , Hypertension, Pregnancy-Induced/pathology , Ventricular Function , Female , Humans , Pregnancy
6.
Obstet Gynecol Surv ; 75(6): 369-380, 2020 Jun.
Article in English | MEDLINE | ID: mdl-32603475

ABSTRACT

IMPORTANCE: The introduction of the cardiotocogram (CTG) during labor has not been found to improve neonatal outcome. The search for a more reliable, less invasive, and patient-friendly technique is ongoing. The noninvasive fetal electrocardiogram (NI-fECG) has been proposed as one such alternative. OBJECTIVES: The aim of this study was to review the literature on the performance of NI-fECG for fetal monitoring during labor. Following the PRISMA guidelines, a systematic search in MEDLINE, EMBASE, and Cochrane Library was performed. Studies involving original research investigating the performance of NI-fECG during labor were included. Animal studies and articles in languages other than English, Dutch, or German were excluded. The QUADAS-2 checklist was used for quality assessment. A descriptive analysis of the results is provided. RESULTS: Eight articles were included. Pooled analysis of the results of the separate studies was not possible due to heterogeneity. All studies demonstrate that it is possible to apply NI-fECG during labor. Compared with Doppler ultrasound, NI-fECG performs equal or better in most studies. CONCLUSIONS AND RELEVANCE: NI-fECG for fetal monitoring is a promising noninvasive and patient-friendly technique that provides accurate information. Future studies should focus on signal quality throughout labor, with the aim to further optimize technical development of NI-fECG.


Subject(s)
Electrocardiography/methods , Fetal Heart/physiology , Heart Rate, Fetal , Female , Humans , Labor, Obstetric , Pregnancy , Reproducibility of Results , Signal-To-Noise Ratio
7.
BMC Pregnancy Childbirth ; 20(1): 215, 2020 Apr 15.
Article in English | MEDLINE | ID: mdl-32293330

ABSTRACT

BACKGROUND: Twin pregnancy is associated with increased perinatal mortality. Close foetal monitoring is therefore warranted. Doppler Ultrasound cardiotocography is currently the only available method to monitor both individual foetuses. Unfortunately, the performance measures of this method are poor and erroneous monitoring of the same twin with both transducers may occur, leaving the second twin unmonitored. In this study we aimed to determine the feasibility of monitoring both foetuses simultaneously in twin gestation by means of non-invasive foetal electrocardiography (NI-fECG), using an electrode patch on the maternal abdomen. METHODS: A NI-fECG recording was performed at 25 + 3 weeks of gestation on a multiparous woman pregnant with dichorionic diamniotic twins. An electrode patch consisting of eight adhesive electrodes was applied on the maternal abdomen, yielding six channels of bipolar electrophysiological measurements. The output was digitized and stored for offline processing. The recorded signals were preprocessed by suppression of high-frequency noise, baseline wander, and powerline interference. Secondly, the maternal ECG was subtracted and segmentation into individual ECG complexes was performed. Finally, ensemble averaging of these individual ECG complexes was performed to suppress interferences. RESULTS: Six different recordings were obtained from each of the six recording channels. Depending on the orientation and distance of the fetal heart with respect to each electrode, a distinction could be made between each fetus based on the morphology of the signals. Yielding of the fetal ECGs was performed manually based on the QRS complexes of each fetus. CONCLUSION: NI-fECG with multiple electrodes allows for monitoring of the fetal heart rate and ECG of both individual fetuses in twin pregnancies.


Subject(s)
Electrocardiography/methods , Fetal Monitoring/methods , Heart Rate, Fetal , Pregnancy, Twin , Adult , Electrodes , Feasibility Studies , Female , Humans , Netherlands , Pregnancy , Prenatal Care/methods , Signal Processing, Computer-Assisted
8.
Acta Obstet Gynecol Scand ; 99(10): 1387-1395, 2020 10.
Article in English | MEDLINE | ID: mdl-32306380

ABSTRACT

INTRODUCTION: Doppler ultrasound cardiotocography is a non-invasive alternative that, despite its poor specificity, is often first choice for intrapartum monitoring. Doppler ultrasound suffers from signal loss due to fetal movements and is negatively correlated with maternal body mass index (BMI). Reported accuracy of fetal heart rate monitoring by Doppler ultrasound varies between 10.6 and 14.3 bpm and reliability between 62.4% and 73%. The fetal scalp electrode (FSE) is considered the reference standard for fetal monitoring but can only be applied after membranes have ruptured with sufficient cervical dilatation and is sometimes contra-indicated. A non-invasive alternative that overcomes the shortcomings of Doppler ultrasound, providing reliable information on fetal heart rate, could be the answer. Non-invasive fetal electrocardiography (NI-fECG) uses a wireless electrode patch on the maternal abdomen to obtain both fetal and maternal heart rate signals as well as an electrohysterogram. We aimed to validate a wireless NI-fECG device for intrapartum monitoring in term singleton pregnancies, by comparison with the FSE. MATERIAL AND METHODS: We performed a multicenter cross-sectional observational study at labor wards of 6 hospitals located in the Netherlands, Belgium, and Spain. Laboring women with a healthy singleton fetus in cephalic presentation and gestational age between 36 and 42 weeks were included. Participants received an abdominal electrode patch and FSE after written informed consent. Accuracy, reliability, and success rate of fetal heart rate readings were determined, using FSE as reference standard. Analysis was performed for the total population and measurement period as well as separated by labor stage and BMI class (≤30 and >30 kg/m2 ). RESULTS: We included a total of 125 women. Simultaneous registrations with NI-fECG and FSE were available in 103 women. Overall accuracy is -1.46 bpm and overall reliability 86.84%. Overall success rate of the NI-fECG is around 90% for the total population as well as for both BMI subgroups. Success rate dropped to 63% during second stage of labor, similar results are found when looking at the separate BMI groups. CONCLUSIONS: Performance measures of the NI-fECG device are good in the overall group and the separate BMI groups. Compared with Doppler ultrasound performance measures from the literature, NI-fECG is a more accurate alternative. Especially, when women have a higher BMI, NI-fECG performs well, resembling FSE performance measures.


Subject(s)
Cardiotocography/instrumentation , Heart Rate, Fetal , Wireless Technology , Adult , Body Mass Index , Cardiotocography/methods , Cross-Sectional Studies , Electrodes , Female , Humans , Pregnancy , Prospective Studies , Reproducibility of Results
9.
AJP Rep ; 8(3): e184-e191, 2018 Jul.
Article in English | MEDLINE | ID: mdl-30250758

ABSTRACT

Objective To evaluate preferences from patients and users on 3 uterine monitoring techniques, during labor. Study Design Women in term labor were simultaneously monitored with the intrauterine pressure catheter, the external tocodynamometer, and the electrohysterograph. Postpartum, these women filled out a questionnaire evaluating their preferences and important aspects. Nurses completed a questionnaire evaluating users' preferences. Results Of all 52 participating women, 80.8% preferred the electrohysterograph, 17.3% the intrauterine pressure catheter and 1.9% the external tocodynamometer. For these women, the electrohysterograph scored best regarding application and presence during labor ( p < 0.001). Most important aspects were "least likely to harm" and "least discomfort". Of 57 nurses, 40.4% preferred the electrohysterograph, 35.1% the external tocodynamometer, and 24.6% had no preference, or replied that their preference is subject to situation and patient. Conclusion Patients prefer the electrohysterograph over the external tocodynamometer and the intrauterine pressure catheter, while healthcare providers report ambiguous results.

10.
Am J Obstet Gynecol ; 208(3): 187.e1-187.e13, 2013 Mar.
Article in English | MEDLINE | ID: mdl-23333546

ABSTRACT

OBJECTIVE: The purpose of this study was to assess the effectiveness of electronic fetal monitoring (EFM) alone and with additional ST analysis (EFM + ST) in laboring women with a singleton term pregnancy that is in cephalic presentation in the prevention of metabolic acidosis by the application of individual patient data metaanalysis. STUDY DESIGN: We conducted an individual patient data metaanalysis using data from 4 randomized trials, which enabled us to account for missing data and investigate relevant subgroups. The primary outcome was metabolic acidosis, which was defined as an umbilical cord-artery pH <7.05 and a base deficit that had been calculated in the extra cellular fluid compartment >12 mmol/L. We performed 8 explanatory subgroup analyses for 8 different endpoints. RESULTS: We analyzed data from 12,987 women and their newborn infants. Metabolic acidosis was present in 57 women (0.9%) in the EFM + ST group and 73 women (1.1%) in the EFM alone group (relative risk [RR], 0.76; 95% CI, 0.53-1.10). Compared with EFM alone, the use of EFM + ST resulted in a reduction in the frequency of instrumental vaginal deliveries (RR, 0.90; 95% CI, 0.83-0.99) and fetal blood samples (RR, 0.49; 95% CI, 0.44-0.55). Cesarean delivery rates were comparable between both groups (RR, 0.99; 95% CI, 0.91-1.09). Subgroup analyses showed that EFM + ST resulted in fewer admissions to a neonatal intensive care unit for women with a duration of pregnancy of >41 weeks (RR, 0.61; 95% CI, 0.39-0.95). CONCLUSION: EFM + ST does not reduce the risk of metabolic acidosis, but it does reduce the need for instrumental vaginal deliveries and fetal blood sampling.


Subject(s)
Fetal Monitoring/methods , Labor, Obstetric , Pregnancy Trimester, Third , Acidosis/diagnosis , Adult , Cardiotocography/methods , Delivery, Obstetric , Female , Humans , Infant, Newborn , Pregnancy
11.
Acta Obstet Gynecol Scand ; 92(1): 85-93, 2013 Jan.
Article in English | MEDLINE | ID: mdl-22994792

ABSTRACT

OBJECTIVE: To assess substandard care factors in the case of delivery-related asphyxia. DESIGN: Prospective cohort study. SETTING: Catchment area of the Neonatal Intensive Care Unit (NICU) of the University Medical Center Utrecht; a region in the middle of the Netherlands covering 13% of the Dutch population. POPULATION: Term infants, without congenital malformations, who died intrapartum or were admitted to the Neonatal Intensive Care Unit due to asphyxia. METHODS: During a two-year period, cases were prospectively collected and audited by an expert panel. MAIN OUTCOME MEASURES: Substandard care factors. RESULTS: 37 735 term infants without congenital malformations were born. There were 19 intrapartum deaths, and 89 NICU admissions of which 12 neonates died. In 63 (58%) cases a substandard care factor was identified that was possibly (n= 47, 43%) or probably (n= 16, 15%) related to perinatal death or NICU admission. In primary care, substandard care factors were mainly the low frequency of examination during labor and delay in referral to secondary care. In secondary care, misinterpretation of cardiotocography and failure to respond adequately to clinical signs of fetal distress were the most common substandard care factors. CONCLUSIONS: Substandard care is present in a substantial number of cases with delivery-related asphyxia resulting in perinatal death or NICU admission. Improving the organization of obstetric care in the Netherlands as well as training of obstetric caregivers might reduce adverse outcomes.


Subject(s)
Asphyxia Neonatorum/etiology , Delivery, Obstetric/adverse effects , Quality of Health Care , Adult , Asphyxia Neonatorum/epidemiology , Cardiotocography , Female , Humans , Infant, Newborn , Netherlands/epidemiology , Pregnancy , Pregnancy Outcome/epidemiology , Prospective Studies , Risk Factors
12.
Acta Obstet Gynecol Scand ; 91(7): 830-7, 2012 Jul.
Article in English | MEDLINE | ID: mdl-22536843

ABSTRACT

OBJECTIVE: To evaluate whether correct adherence to clinical guidelines might have led to prevention of cases with adverse neonatal outcome. DESIGN: Secondary analysis of cases with adverse outcome in a multicenter randomized clinical trial. SETTING: Nine Dutch hospitals. POPULATION: Pregnant women with a term singleton fetus in cephalic position. METHODS: Data were obtained from a randomized trial that compared monitoring by STAN® (index group) with cardiotocography (control group). In both trial arms, three observers independently assessed the fetal surveillance results in all cases with adverse neonatal outcome, to determine whether an indication for intervention was present, based on current clinical guidelines. MAIN OUTCOME MEASURES: Adverse neonatal outcome cases fulfilled one or more of the following criteria: (i) metabolic acidosis in umbilical cord artery (pH < 7.05 and base deficit in extracellular fluid >12 mmol/L); (ii) umbilical cord artery pH < 7.00; (iii) perinatal death; and/or (iv) signs of moderate or severe hypoxic ischemic encephalopathy. RESULTS: We studied 5681 women, of whom 61 (1.1%) had an adverse outcome (26 index; 35 control). In these women, the number of performed operative deliveries for fetal distress was 18 (69.2%) and 16 (45.7%), respectively. Reassessment of all 61 cases showed that there was a fetal indication to intervene in 23 (88.5%) and 19 (57.6%) cases, respectively. In 13 (50.0%) vs. 11 (33.3%) cases, respectively, this indication occurred more than 20 min before the time of delivery, meaning that these adverse outcomes could possibly have been prevented. CONCLUSIONS: In our trial, more strict adherence to clinical guidelines could have led to additional identification and prevention of adverse outcome.


Subject(s)
Cardiotocography , Electrocardiography , Fetal Distress/diagnosis , Fetal Monitoring/methods , Guideline Adherence , Acidosis/diagnosis , Adult , Female , Heart Rate, Fetal , Humans , Hypoxia-Ischemia, Brain/diagnosis , Infant, Newborn , Intensive Care Units, Neonatal , Pregnancy , Pregnancy Outcome , Umbilical Arteries
13.
Am J Perinatol ; 29(3): 167-74, 2012 Mar.
Article in English | MEDLINE | ID: mdl-21815125

ABSTRACT

We sought to predict neonatal metabolic acidosis at birth using antepartum obstetric characteristics (model 1) and additional characteristics available during labor (model 2). In 5667 laboring women from a multicenter randomized trial that had a high-risk singleton pregnancy in cephalic presentation beyond 36 weeks of gestation, we predicted neonatal metabolic acidosis. Based on literature and clinical reasoning, we selected both antepartum characteristics and characteristics that became available during labor. After univariable analyses, the predictors of the multivariable models were identified by backward stepwise selection in a logistic regression analysis. Model performance was assessed by discrimination and calibration. To correct for potential overfitting, we (internally) validated the models with bootstrapping techniques. Of 5667 neonates born alive, 107 (1.9%) had metabolic acidosis. Antepartum predictors of metabolic acidosis were gestational age, nulliparity, previous cesarean delivery, and maternal diabetes. Additional intrapartum predictors were spontaneous onset of labor and meconium-stained amniotic fluid. Calibration and discrimination were acceptable for both models (c-statistic 0.64 and 0.66, respectively). In women with a high-risk singleton term pregnancy in cephalic presentation, we identified antepartum and intrapartum factors that predict neonatal metabolic acidosis at birth.


Subject(s)
Acidosis/epidemiology , Models, Statistical , Pregnancy Complications/metabolism , Cesarean Section , Diabetes, Gestational , Female , Forecasting , Gestational Age , Humans , Infant, Newborn , Labor, Obstetric , Parity , Pregnancy , Reproducibility of Results , Risk Factors
14.
Acta Obstet Gynecol Scand ; 91(2): 189-97, 2012 Feb.
Article in English | MEDLINE | ID: mdl-22066545

ABSTRACT

OBJECTIVE: To evaluate the added value of the baseline T/QRS ratio to other known risk factors in predicting adverse outcome and interventions for suspected fetal distress. DESIGN: Prospective cohort study. SETTING: Three academic and six non-academic teaching hospitals in the Netherlands. POPULATION: Laboring women with a high-risk cephalic singleton pregnancy beyond 36 weeks of gestation. METHODS: We obtained STAN(®) recordings (ST-analysis, Neoventa, Sweden) from two previous studies. Three patient groups were defined: cases with adverse outcome, cases with emergency delivery because of suspected fetal distress without adverse outcome, and a reference group of uncomplicated cases. Baseline T/QRS ratios among the adverse outcome and intervention for suspected fetal distress cases were compared to those of the uncomplicated cases. The ability of baseline T/QRS to predict adverse outcome and suspected fetal distress was determined using a multivariable logistic model. MAIN OUTCOME MEASURES: The added value of the baseline T/QRS to other known risk factors in the prediction of adverse outcome and interventions for suspected fetal distress. RESULTS: From 3462 recordings, 2459 were available for analysis. Median baseline T/QRS for uncomplicated cases, adverse outcome and interventions for suspected fetal distress were 0.12 (range 0.00-0.52), 0.12 (0.00-0.42) and 0.13 (0.00-0.39), respectively. There was no statistical difference between these groups. Multivariable analysis showed no added value of baseline T/QRS in the prediction of either adverse outcome or interventions for suspected fetal distress. CONCLUSION: Baseline T/QRS has no added value in the prediction of adverse neonatal outcome or interventions for suspected fetal distress.


Subject(s)
Electrocardiography , Fetal Distress/diagnosis , Fetal Monitoring/methods , Adult , Female , Humans , Infant, Newborn , Logistic Models , Predictive Value of Tests , Pregnancy , Pregnancy Outcome , Prospective Studies , ROC Curve
15.
Obstet Gynecol ; 119(1): 145-54, 2012 Jan.
Article in English | MEDLINE | ID: mdl-22183222

ABSTRACT

OBJECTIVE: To compare the effects of ST-waveform analysis in combination with cardiotocography with conventional cardiotocography for intrapartum fetal monitoring. DATA SOURCES: We searched MEDLINE, Embase, and PubMed for randomized controlled trials (RCTs) evaluating ST-waveform analysis for intrapartum fetal monitoring. METHODS OF STUDY SELECTION: We identified RCTs that compared ST-waveform analysis and conventional cardiotocography for intrapartum fetal monitoring of singleton pregnancies in cephalic presentation beyond 34 weeks of gestation and evaluating at least one of the following: metabolic acidosis, umbilical cord pH less than 7.15, umbilical cord pH less than 7.10, umbilical cord pH less than 7.05, umbilical cord pH less than 7.00, Apgar scores less than 7 at 5 minutes, admittance to the neonatal intensive care unit, need for intubation, presence of hypoxic ischemic encephalopathy, perinatal death, operative delivery, and number of fetal blood samplings. TABULATION, INTEGRATION, AND RESULTS: Five RCTs, which included 15,352 patients, met the selection criteria. Random-effects models were used to estimate the combined relative risks (RRs) of ST analysis compared with conventional cardiotocography. Compared with conventional cardiotocography, ST analysis showed a nonsignificant reduction in metabolic acidosis (RR 0.72, 95% confidence interval 0.43-1.19, number needed to treat [NNT] 357). ST analysis significantly reduced the incidence of additional fetal blood sampling (RR 0.59, 95% confidence interval 0.44-0.79, NNT 11), operative vaginal deliveries (RR 0.88, 95% confidence interval 0.80-0.97, NNT 64), and total operative deliveries (RR 0.94, 95% confidence interval 0.89-0.99, NNT 64). For other outcomes, no differences in effect were seen between ST analysis and conventional cardiotocography, or data were not suitable for meta-analysis. CONCLUSION: The additional use of ST analysis for intrapartum monitoring reduced the incidence of operative vaginal deliveries and the need for fetal blood sampling but did not reduce the incidence of metabolic acidosis at birth.


Subject(s)
Cardiotocography , Electrocardiography , Delivery, Obstetric/statistics & numerical data , Female , Humans , Pregnancy , Pregnancy Outcome , Randomized Controlled Trials as Topic
16.
Acta Obstet Gynecol Scand ; 90(12): 1364-70, 2011 Dec.
Article in English | MEDLINE | ID: mdl-21950541

ABSTRACT

OBJECTIVE: To evaluate the influence of intrapartum epidural analgesia on the occurrence of ST events of the fetal ECG. DESIGN: Nested case-control study. SETTING: Single-centre academic hospital in the Netherlands. POPULATION: Laboring women with a high-risk singleton pregnancy in cephalic position beyond 36 weeks of gestation. METHODS: Data of 72 women who received epidural analgesia using bupivacaine combined with sufentanil and 72 control women were collected and analyzed. The moment of epidural infusion was defined as t(0) . In the control group, t(0) was defined by matching dilatation in centimeters. STAN registrations from one hour before until two hours after t(0) were classified, and the numbers and types of ST events were recorded and judged according to the STAN clinical guidelines. T/QRS ratios were collected from one hour before t(0) until two hours after t(0) , and differences were compared between the two groups. MAIN OUTCOME MEASURES: Numbers and types of ST events and mean T/QRS ratios before and after t(0). RESULTS: There were no significant differences between cases and control women regarding the numbers of ST events, types of ST events and whether they were significant (intervention advised) or not. Correction for outliers (three cases and three control women) did not change the results. Differences of T/QRS ratios before and after t(0) were comparable between cases and control women. CONCLUSIONS: Epidural analgesia has no effect on the numbers or types of ST events when using ST analysis of the fetal ECG.


Subject(s)
Analgesia, Epidural/adverse effects , Analgesia, Obstetrical/adverse effects , Bupivacaine/pharmacology , Electrocardiography/drug effects , Fetal Heart/drug effects , Sufentanil/pharmacology , Analgesics, Opioid/pharmacology , Anesthetics, Local/pharmacology , Case-Control Studies , Female , Fetal Monitoring , Humans , Infant, Newborn , Labor, Obstetric , Male , Pregnancy , Pregnancy, High-Risk , Single-Blind Method
17.
Obstet Gynecol Surv ; 66(1): 42-6, 2011 Jan.
Article in English | MEDLINE | ID: mdl-21510911

ABSTRACT

UNLABELLED: In a recently published randomized clinical trial on intrapartum fetal monitoring, fetal blood samples were obtained in 879 women. One serious complication of fetal blood sampling (FBS) was reported, a case in which physical examination of the neonate after delivery revealed clear fluid loss from the incision site. Four layers of the scalp appeared to be incised. The subarachnoid space was closed with 2 sutures, and antibiotics were started due to the risk of meningitis. The patient was discharged in good clinical condition. In this article, the case is presented and the literature reviewed. We found 12 articles reporting 37 cases of a complication due to FBS, none concerning leakage of cerebrospinal fluid. In conclusion, complications of FBS are rare but can be serious. Excessive fetal bleeding is most frequently reported and often associated with an underlying coagulopathy in the neonate. TARGET AUDIENCE: Obstetricians & Gynecologists, Family Physicians. LEARNING OBJECTIVES: After completion of this educational activity, the obstetrician/gynecologist should be better able to assess the chance of possible complications due to fetal blood sampling; select fetuses at risk for complications due to fetal blood sampling; and evaluate certain technical precautions when performing this procedure.


Subject(s)
Blood Specimen Collection/adverse effects , Fetal Blood/chemistry , Fetal Monitoring/adverse effects , Scalp/injuries , Adult , Cerebrospinal Fluid Leak , Cerebrospinal Fluid Rhinorrhea/etiology , Female , Fetal Monitoring/methods , Hemorrhage/etiology , Humans , Infant, Newborn , Male , Pregnancy , Scalp/microbiology
18.
Acta Obstet Gynecol Scand ; 90(7): 772-8, 2011 Jul.
Article in English | MEDLINE | ID: mdl-21446929

ABSTRACT

OBJECTIVE: To assess the cost-effectiveness of addition of ST analysis of the fetal electrocardiogram (ECG; STAN) to cardiotocography (CTG) for fetal surveillance during labor compared with CTG only. DESIGN: Cost-effectiveness analysis based on a randomized clinical trial on ST analysis of the fetal ECG. SETTING: Obstetric departments of three academic and six general hospitals in The Netherlands. Population. Laboring women with a singleton high-risk pregnancy, a fetus in cephalic presentation, a gestational age >36 weeks and an indication for internal electronic fetal monitoring. METHODS: A trial-based cost-effectiveness analysis was performed from a health-care provider perspective. MAIN OUTCOME MEASURES: Primary health outcome was the incidence of metabolic acidosis measured in the umbilical artery. Direct medical costs were estimated from start of labor to childbirth. Cost-effectiveness was expressed as costs to prevent one case of metabolic acidosis. RESULTS: The incidence of metabolic acidosis was 0.7% in the ST-analysis group and 1.0% in the CTG-only group (relative risk 0.70; 95% confidence interval 0.38-1.28). Per delivery, the mean costs per patient of CTG plus ST analysis (n= 2 827) were €1,345 vs. €1,316 for CTG only (n= 2 840), with a mean difference of €29 (95% confidence interval -€9 to €77) until childbirth. The incremental costs of ST analysis to prevent one case of metabolic acidosis were €9 667. CONCLUSIONS: The additional costs of monitoring by ST analysis of the fetal ECG are very limited when compared with monitoring by CTG only and very low compared with the total costs of delivery.


Subject(s)
Cardiotocography/economics , Electrocardiography/economics , Fetal Monitoring/economics , Health Care Costs , Pregnancy Outcome , Pregnancy, High-Risk , Acidosis/diagnosis , Acidosis/epidemiology , Adult , Cardiotocography/methods , Cost Savings , Cost-Benefit Analysis , Delivery, Obstetric/economics , Delivery, Obstetric/methods , Electrocardiography/methods , Female , Fetal Blood/chemistry , Fetal Monitoring/methods , Gestational Age , Humans , Netherlands , Pregnancy , Pregnancy Trimester, Third , Young Adult
20.
Obstet Gynecol ; 115(6): 1173-1180, 2010 Jun.
Article in English | MEDLINE | ID: mdl-20502287

ABSTRACT

OBJECTIVE: To estimate the effectiveness of intrapartum fetal monitoring by cardiotocography plus ST analysis using a strict protocol for performance of fetal blood sampling. METHODS: We performed a multicenter randomized trial among laboring women with a high-risk singleton pregnancy in cephalic presentation beyond 36 weeks of gestation. Participants were assigned to monitoring by cardiotocography with ST analysis (index) or cardiotocography only (control). Primary outcome was metabolic acidosis, defined as an umbilical cord artery pH below 7.05 combined with a base deficit calculated in the extracellular fluid compartment above 12 mmol/L. Secondary outcomes were metabolic acidosis in blood, operative deliveries, Apgar scores, neonatal admissions, and hypoxic-ischemic encephalopathy. RESULTS: We randomly assigned 5,681 women to the two groups (2,832 index, 2,849 control). The fetal blood sampling rate was 10.6% in the index compared with 20.4% in the control group (relative risk 0.52; 95% [CI] 0.46-0.59). The primary outcome occurred 0.7% in the index compared with 1.1% in the control group (relative risk 0.70; 95% CI 0.38-1.28; number needed to treat 252). Using metabolic acidosis calculated in blood, these rates were 1.6% and 2.6%, respectively (relative risk 0.63; 95% CI 0.42-0.94; number needed to treat 100). The number of operative deliveries, low Apgar scores, neonatal admissions, and newborns with hypoxic-ischemic encephalopathy was comparable in both groups. CONCLUSION: Intrapartum monitoring by cardiotocography combined with ST analysis does not significantly reduce the incidence of metabolic acidosis calculated in the extracellular fluid compartment. It does reduce the incidence of metabolic acidosis calculated in blood and the need for fetal blood sampling without affecting the Apgar score, neonatal admissions, hypoxic-ischemic encephalopathy, or operative deliveries. LEVEL OF EVIDENCE: I.


Subject(s)
Acidosis/prevention & control , Cardiotocography/methods , Electrocardiography , Adult , Female , Humans , Hypoxia-Ischemia, Brain/prevention & control , Infant, Newborn , Pregnancy
SELECTION OF CITATIONS
SEARCH DETAIL
...