Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Phys Med Biol ; 59(11): 2801-11, 2014 Jun 07.
Article in English | MEDLINE | ID: mdl-24801363

ABSTRACT

We show that the microvasculature of mouse tumors can be visualized using propagation-based phase-contrast x-ray imaging with gas as the contrast agent. The large density difference over the gas-tissue interface provides high contrast, allowing the imaging of small-diameter blood vessels with relatively short exposure times and low dose using a compact liquid-metal-jet x-ray source. The method investigated is applied to tumors (E1A/Ras-transformed mouse embryonic fibroblasts) grown in mouse ears, demonstrating sub-15-µm-diameter imaging of their blood vessels. The exposure time for a 2D projection image is a few seconds and a full tomographic 3D map takes some minutes. The method relies on the strength of the vasculature to withstand the gas pressure. Given that tumor vessels are known to be more fragile than normal vessels, we investigate the tolerance of the vasculature of 12 tumors to gas injection and find that a majority withstand 200 mbar pressures, enough to fill 12-µm-diameter vessels with gas. A comparison of the elasticity of tumorous and non-tumorous vessels supports the assumption of tumor vessels being more fragile. Finally, we conclude that the method has the potential to be extended to the imaging of 15 µm vessels in thick tissue, including mouse imaging, making it of interest for, e.g., angiogenesis research.


Subject(s)
Angiography/methods , Carbon Dioxide , Contrast Media , Animals , Ear Neoplasms/blood supply , Ear Neoplasms/diagnostic imaging , Imaging, Three-Dimensional , Injections , Mice
2.
Phys Med Biol ; 57(22): 7431-41, 2012 Nov 21.
Article in English | MEDLINE | ID: mdl-23093393

ABSTRACT

X-ray in-line phase contrast has recently been combined with CO(2) angiography for high-resolution small-animal vascular imaging at low radiation dose. In this paper we further investigate the potential and limitations of this method and demonstrate observation of vessels down to 8 µm in diameter, considerably smaller than the 60 µm previously reported. Our in-line phase-contrast imaging system is based on a liquid-metal-jet-anode x-ray source and utilizes free-space propagation to convert phase shifts, caused by refractive index variations, into intensity differences. Enhanced refractive index variations are obtained through injection of CO(2) gas into the vascular system to replace the blood. We show rat-kidney images with blood vessels down to 27 µm in diameter and mouse-ear images with vessels down to 8 µm. The minimum size of observable blood vessels is found to be limited by the penetration of gas into the vascular system and the signal-to-noise ratio, i.e. the allowed dose. The diameters of vessels being gas-filled depend on the gas pressure and follow a simple model based on surface tension. A theoretical signal-to-noise comparison shows that this method requires 1000 times less radiation dose than conventional iodine-based absorption contrast for observing sub-50 µm vessels.


Subject(s)
Angiography/methods , Carbon Dioxide , Contrast Media , Animals , Ear/blood supply , Kidney/blood supply , Mice , Rats
SELECTION OF CITATIONS
SEARCH DETAIL
...