Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 52
Filter
1.
mBio ; 13(2): e0284521, 2022 04 26.
Article in English | MEDLINE | ID: mdl-35227073

ABSTRACT

Human gut commensal Bacteroidetes rely on multiple transport systems to acquire vitamin B12 and related cobamides for fitness in the gut. In addition to a set of conserved transport proteins, these systems also include a diverse repertoire of additional proteins with unknown function. Here, we report the function and structural characterization of one of these proteins, BtuH, which binds vitamin B12 directly via a C-terminal globular domain that has no known structural homologs. This protein is required for efficient B12 transport and competitive fitness in the gut, demonstrating that members of the heterogeneous suite of accessory proteins encoded in Bacteroides cobamide transport system loci can play key roles in vitamin acquisition. IMPORTANCE The gut microbiome is a complex microbial community with important impacts on human health. One of the major groups within the gut microbiome, the Bacteroidetes, rely on their ability to capture vitamin B12 and related molecules for fitness in the gut. Unlike well-studied model organisms, gut Bacteroidetes genomes often include multiple vitamin B12 transport systems with a heterogeneous set of components. The role, if any, of these components was unknown. Here, we identify new proteins that play key roles in vitamin B12 capture in these organisms. Notably, these proteins are associated with some B12 transport systems and not others (even in the same bacterial strain), suggesting that these systems may assemble into functionally distinct machines to capture vitamin B12 and related molecules.


Subject(s)
Gastrointestinal Microbiome , Vitamin B 12 , Bacteroidetes/genetics , Bacteroidetes/metabolism , Carrier Proteins/metabolism , Humans , Vitamin B 12/metabolism , Vitamins
2.
Atmos Environ X ; 2: 100031, 2019 Apr.
Article in English | MEDLINE | ID: mdl-34322666

ABSTRACT

The United States Environmental Protection Agency held an international two-day workshop in June 2018 to deliberate possible performance targets for non-regulatory fine particulate matter (PM2.5) and ozone (O3) air sensors. The need for a workshop arose from the lack of any market-wide manufacturer requirement for Ozone documented sensor performance evaluations, the lack of any independent third party or government-based sensor performance certification program, and uncertainty among all users as to the general usability of air sensor data. A multi-sector subject matter expert panel was assembled to facilitate an open discussion on these issues with multiple stakeholders. This summary provides an overview of the workshop purpose, key findings from the deliberations, and considerations for future actions specific to sensors. Important findings concerning PM2.5 and O3 sensors included the lack of consistent performance indicators and statistical metrics as well as highly variable data quality requirements depending on the intended use. While the workshop did not attempt to yield consensus on any topic, a key message was that a number of possible future actions would be beneficial to all stakeholders regarding sensor technologies. These included documentation of best practices, sharing quality assurance results along with sensor data, and the development of a common performance target lexicon, performance targets, and test protocols.

3.
Appl Opt ; 57(27): 7871-7877, 2018 Sep 20.
Article in English | MEDLINE | ID: mdl-30462053

ABSTRACT

This work is focused on the role of temperature in the de-mixing of absorbance spectra measured in mixed aqueous Na2SO4 and NaNO3 solutions. First, the influence of temperature on the absorbance spectrum of demineralized water was determined. Second, the absorbance spectra of five separate electrolytes (NaNO2, NaNO3, CaCl2, K2CO3, and NaOH) at three temperatures (4°C, 25°C, and 50°C) for concentrations ranging from 0.0625 M to 0.5 M were examined. These five electrolytes show similar temperature dependencies. Finally, absorbance spectra of mixed solutions were investigated at temperatures of 5°C, 15°C, 25°C, 35°C, and 45°C for concentrations ranging from 0.0625 M to 0.5 M per electrolyte in the mixture. The spectral window from 650 to 1100 nm was utilized to observe the ionic and temperature influences on the vibrational modes of the OH bond in the solvent molecules. The effects of dissolving Na2SO4 and NaNO3 are nonlinearly cumulative at lower temperatures indicating extended alteration of the water structure beyond the first hydration shell. A similar trend was observed for a mixture of Na2CO3 and NaCl. Furthermore, it was found that higher temperatures are better for recovering the separate component absorption signatures of an electrolyte mixture. The near-infrared spectral regime is well suited for integrated sensing, and therefore these results can help in designing an integrated sensor to identify inorganic species in water.

4.
Clin Neurophysiol ; 128(9): 1774-1809, 2017 09.
Article in English | MEDLINE | ID: mdl-28709880

ABSTRACT

Low intensity transcranial electrical stimulation (TES) in humans, encompassing transcranial direct current (tDCS), transcutaneous spinal Direct Current Stimulation (tsDCS), transcranial alternating current (tACS), and transcranial random noise (tRNS) stimulation or their combinations, appears to be safe. No serious adverse events (SAEs) have been reported so far in over 18,000 sessions administered to healthy subjects, neurological and psychiatric patients, as summarized here. Moderate adverse events (AEs), as defined by the necessity to intervene, are rare, and include skin burns with tDCS due to suboptimal electrode-skin contact. Very rarely mania or hypomania was induced in patients with depression (11 documented cases), yet a causal relationship is difficult to prove because of the low incidence rate and limited numbers of subjects in controlled trials. Mild AEs (MAEs) include headache and fatigue following stimulation as well as prickling and burning sensations occurring during tDCS at peak-to-baseline intensities of 1-2mA and during tACS at higher peak-to-peak intensities above 2mA. The prevalence of published AEs is different in studies specifically assessing AEs vs. those not assessing them, being higher in the former. AEs are frequently reported by individuals receiving placebo stimulation. The profile of AEs in terms of frequency, magnitude and type is comparable in healthy and clinical populations, and this is also the case for more vulnerable populations, such as children, elderly persons, or pregnant women. Combined interventions (e.g., co-application of drugs, electrophysiological measurements, neuroimaging) were not associated with further safety issues. Safety is established for low-intensity 'conventional' TES defined as <4mA, up to 60min duration per day. Animal studies and modeling evidence indicate that brain injury could occur at predicted current densities in the brain of 6.3-13A/m2 that are over an order of magnitude above those produced by tDCS in humans. Using AC stimulation fewer AEs were reported compared to DC. In specific paradigms with amplitudes of up to 10mA, frequencies in the kHz range appear to be safe. In this paper we provide structured interviews and recommend their use in future controlled studies, in particular when trying to extend the parameters applied. We also discuss recent regulatory issues, reporting practices and ethical issues. These recommendations achieved consensus in a meeting, which took place in Göttingen, Germany, on September 6-7, 2016 and were refined thereafter by email correspondence.


Subject(s)
Brain/physiology , Practice Guidelines as Topic/standards , Transcranial Direct Current Stimulation/ethics , Transcranial Direct Current Stimulation/standards , Animals , Burns, Electric/etiology , Burns, Electric/prevention & control , Humans , Transcranial Direct Current Stimulation/adverse effects
5.
Water Res ; 67: 243-54, 2014 Dec 15.
Article in English | MEDLINE | ID: mdl-25282092

ABSTRACT

Biofouling causes performance loss in spiral wound nanofiltration (NF) and reverse osmosis (RO) membrane operation for process and drinking water production. The development of biofilm formation, structure and detachment was studied in-situ, non-destructively with Optical Coherence Tomography (OCT) in direct relation with the hydraulic biofilm resistance and membrane performance parameters: transmembrane pressure drop (TMP) and feed-channel pressure drop (FCP). The objective was to evaluate the suitability of OCT for biofouling studies, applying a membrane biofouling test cell operated at constant crossflow velocity (0.1 m s(-1)) and permeate flux (20 L m(-2)h(-1)). In time, the biofilm thickness on the membrane increased continuously causing a decline in membrane performance. Local biofilm detachment was observed at the biofilm-membrane interface. A mature biofilm was subjected to permeate flux variation (20 to 60 to 20 L m(-2)h(-1)). An increase in permeate flux caused a decrease in biofilm thickness and an increase in biofilm resistance, indicating biofilm compaction. Restoring the original permeate flux did not completely restore the original biofilm parameters: After elevated flux operation the biofilm thickness was reduced to 75% and the hydraulic resistance increased to 116% of the original values. Therefore, after a temporarily permeate flux increase the impact of the biofilm on membrane performance was stronger. OCT imaging of the biofilm with increased permeate flux revealed that the biofilm became compacted, lost internal voids, and became more dense. Therefore, membrane performance losses were not only related to biofilm thickness but also to the internal biofilm structure, e.g. caused by changes in pressure. Optical Coherence Tomography proved to be a suitable tool for quantitative in-situ biofilm thickness and morphology studies which can be carried out non-destructively and in real-time in transparent membrane biofouling monitors.


Subject(s)
Biofilms/growth & development , Biofouling , Filtration/instrumentation , Membranes, Artificial , Nanostructures , Tomography, Optical Coherence/methods , Water Purification/instrumentation , Filtration/methods , Water Movements , Water Purification/methods
6.
Phys Biol ; 9(2): 026006, 2012 04.
Article in English | MEDLINE | ID: mdl-22476025

ABSTRACT

When a high-voltage direct-current is applied to two beakers filled with water, a horizontal electrohydrodynamic (EHD) bridge forms between the two beakers. In this work we study the transport and behavior of bacterial cells added to an EHD bridge set-up. Organisms were added to one or to both beakers, and the transport of the cells through the bridge was monitored using optical and microbiological techniques. It is shown that Escherichia coli top10 (Invitrogen, Carlsbad, CA, USA) and bioluminescent E. coli YMC10 with a plasmid (pJE202) containing Vibrio fischeri genes can survive the exposure to an EHD liquid bridge set-up and the cells are drawn toward the anode due to their negative surface charge. Dielectrophoresis and hydrostatic forces are likely to be the cause for their transport in the opposite direction which was observed as well, but to a much lesser extent. Most E. coli YMC10 bacteria which passed the EHD bridge exhibited increased luminescent activity after 24 h. This can be explained by two likely mechanisms: nutrient limitation in the heavier inoculated vials and a 'survival of the strongest' mechanism.

7.
IEEE Trans Vis Comput Graph ; 18(12): 2275-84, 2012 Dec.
Article in English | MEDLINE | ID: mdl-26357135

ABSTRACT

The study of aerosol composition for air quality research involves the analysis of high-dimensional single particle mass spectrometry data. We describe, apply, and evaluate a novel interactive visual framework for dimensionality reduction of such data. Our framework is based on non-negative matrix factorization with specifically defined regularization terms that aid in resolving mass spectrum ambiguity. Thereby, visualization assumes a key role in providing insight into and allowing to actively control a heretofore elusive data processing step, and thus enabling rapid analysis meaningful to domain scientists. In extending existing black box schemes, we explore design choices for visualizing, interacting with, and steering the factorization process to produce physically meaningful results. A domain-expert evaluation of our system performed by the air quality research experts involved in this effort has shown that our method and prototype admits the finding of unambiguous and physically correct lower-dimensional basis transformations of mass spectrometry data at significantly increased speed and a higher degree of ease.

9.
J Phys Chem A ; 115(15): 3461-74, 2011 Apr 21.
Article in English | MEDLINE | ID: mdl-21438500

ABSTRACT

A Pitzer ion interaction model has been applied to the systems H(2)SO(4)-H(2)O (0-3 mol kg(-1), 0-55 °C) and H(2)SO(4)-(NH(4))(2)SO(4)-H(2)O (0-6 mol kg(-1), 25 °C) for the calculation of apparent molar volume and density. The dissociation reaction HSO(4)(-)((aq)) ↔ H(+)((aq)) + SO(4)(2-)((aq)) is treated explicitly. Apparent molar volumes of the SO(4)(2-) ion at infinite dilution were obtained from part 1 of this work, (1) and the value for the bisulfate ion was determined in this study from 0 to 55 °C. In dilute solutions of both systems, the change in the degree of dissociation of the HSO(4)(-) ion with concentration results in much larger variations of the apparent molar volumes of the solutes than for conventional strong (fully dissociated) electrolytes. Densities and apparent molar volumes are tabulated. Apparent molar volumes calculated using the model are combined with other data for the solutes NH(4)HSO(4) and (NH(4))(3)H(SO(4))(2) at 25 °C to obtain apparent molar volumes and densities over the entire concentration range (including solutions supersaturated with respect to the salts).

10.
J Phys Chem A ; 115(15): 3393-460, 2011 Apr 21.
Article in English | MEDLINE | ID: mdl-21438504

ABSTRACT

Calculations of the size and density of atmospheric aerosols are complicated by the fact that they can exist at concentrations highly supersaturated with respect to dissolved salts and supercooled with respect to ice. Densities and apparent molar volumes of solutes in aqueous solutions containing the solutes H(2)SO(4), HNO(3), HCl, Na(2)SO(4), NaNO(3), NaCl, (NH(4))(2)SO(4), NH(4)NO(3), and NH(4)Cl have been critically evaluated and represented using fitted equations from 0 to 50 °C or greater and from infinite dilution to concentrations saturated or supersaturated with respect to the dissolved salts. Using extrapolated densities of high-temperature solutions and melts, the relationship between density and concentration is extended to the hypothetical pure liquid solutes. Above a given reference concentration of a few mol kg(-1), it is observed that density increases almost linearly with decreasing temperature, and comparisons with available data below 0 °C suggest that the fitted equations for density can be extrapolated to very low temperatures. As concentration is decreased below the reference concentration, the variation of density with temperature tends to that of water (which decreases as temperature is reduced below 3.98 °C). In this region below the reference concentration, and below 0 °C, densities are calculated using extrapolated apparent molar volumes which are constrained to agree at the reference concentrations with an equation for the directly fitted density. Calculated volume properties agree well with available data at low temperatures, for both concentrated and dilute solutions. Comparisons are made with literature data for temperatures of maximum density. Apparent molar volumes at infinite dilution are consistent, on a single ion basis, to better than ±0.1 cm(3) mol(-1) from 0 to 50 °C. Volume properties of aqueous NaHSO(4), NaOH, and NH(3) have also been evaluated, at 25 °C only. In part 2 of this work (ref 1 ) an ion interaction (Pitzer) model has been used to calculate apparent molar volumes of H(2)SO(4) in 0-3 mol kg(-1) aqueous solutions of the pure acid and to represent directly the effect of the HSO(4)(-) ↔ H(+) + SO(4)(2-) reaction. The results are incorporated into the treatment of aqueous H(2)SO(4) density described here. Densities and apparent molar volumes from -20 to 50 °C, and from 0 to 100 wt % of solute, are tabulated for the electrolytes listed in the title and have also been incorporated into the extended aerosol inorganics model (E-AIM, http://www.aim.env.uea.ac.uk/aim/aim.php) together with densities of the solid salts and hydrates.


Subject(s)
Atmosphere/chemistry , Temperature , Ammonia/chemistry , Ammonium Chloride/chemistry , Ammonium Sulfate/chemistry , Electrolytes/chemistry , Hydrochloric Acid/chemistry , Nitrates/chemistry , Nitric Acid/chemistry , Sodium Chloride/chemistry , Sodium Hydroxide/chemistry , Solubility , Solutions , Sulfates/chemistry , Sulfuric Acids/chemistry
11.
Environ Sci Technol ; 43(24): 9445-52, 2009 Dec 15.
Article in English | MEDLINE | ID: mdl-20000542

ABSTRACT

Current particulate matter regulations control the mass concentration of particles in the atmosphere regardless of composition, but some primary and/or secondary particulate matter components are no doubt more or less toxic than others. Testing direct emissions of pollutants from different sources neglects atmospheric transformations that may increase or decrease their toxicity. This work describes a system that conditionally samples particles from the atmosphere depending on the sources or source combinations that predominate at the sampling site at a given time. A single particle mass spectrometer (RSMS-II), operating in the 70-150 nm particle diameter range, continuously provides the chemical composition of individual particles. The mass spectra indicate which sources are currently affecting the site. Ten ChemVol samplers are each assigned one source or source combination, and the RSMS-II controls which one operates depending on the sources or source combinations observed. By running this system for weeks at a time, sufficient sample is collected by the ChemVols for comparative toxicological studies. This paper describes the instrument and algorithmic design, implementation, and first results from operating this system in Fresno, CA, during summer 2008 and winter 2009.


Subject(s)
Air Pollutants/analysis , Environmental Monitoring , Mass Spectrometry/instrumentation , Particulate Matter/analysis , Algorithms , Animals , Environmental Monitoring/instrumentation , Environmental Monitoring/methods , Mass Spectrometry/methods , Particle Size
14.
Acta Physiol (Oxf) ; 189(4): 337-46, 2007 Apr.
Article in English | MEDLINE | ID: mdl-17367403

ABSTRACT

AIM: The purpose of the present study was to investigate the effect of activation frequency on dynamic human muscle performance for a range of train durations and number of pulses during free limb movement. METHODS: The quadriceps femoris muscles of 10 subjects were activated with stimulation trains with different activation frequency, train durations and number of pulses. The peak excursion produced in response to each train was the dependent measure of muscle performance. RESULTS: The excursion-frequency (for a 300-ms train duration) and excursion-train duration (for trains with frequencies of 10, 30 or 59 Hz) relationships could each be fit with a two-parameter exponential equation (R(2) values > 0.97). Because the number of pulses in a stimulation train is a function of both train duration and frequency, the excursion produced as a function of the number of pulses was characterized by a three-parameter exponential equation that represented this combined relationship. The relationship between the measured and predicted excursions in response to a wide range of stimulation trains had a R(2) = 0.96. In addition, one-way repeated measures analyses of variance (anovas) showed that the frequency at which the maximum excursion was produced increased with an increase in the number of pulses in the trains tested. CONCLUSION: These results show the importance of train duration and the number of pulses contained within a train on the relationship between activation frequency and human skeletal muscle performance.


Subject(s)
Electric Stimulation/methods , Quadriceps Muscle/physiology , Adolescent , Adult , Exercise Test/methods , Female , Humans , Isometric Contraction , Isotonic Contraction , Knee Joint/physiology , Male , Movement/physiology , Muscle Contraction/physiology
15.
Ann Acad Med Singap ; 34(5): 383-8, 2005 Jun.
Article in English | MEDLINE | ID: mdl-16021229

ABSTRACT

INTRODUCTION: Dental implants are increasingly used to restore missing dentition. These titanium implants are surgically installed in the edentulous alveolar ridge and allowed to osteointegrate with the bone during the healing phase. After osseo-integration, the implant is loaded with a prosthesis to replace the missing tooth. Conventional implant treatment planning uses study models, wax-ups and panoramic x-rays to prefabricate surgical stent to guide the preparation of the implant site. The drilling into the alveolar ridge is invariably a "blind" procedure as the part of the drill in bone is not visible. Stereotactic systems were first introduced into neurosurgery in 1986. Since then, computer-assisted navigational technology has brought major advances to neuro-, midface and orthopaedic surgeries, and more recently, to implant placement. CLINICAL FEATURE: This paper illustrates the use of real-time computer-guided navigational technology in enhancing safety in implant surgical procedures. OUTCOME AND CONCLUSION: Real-time computer-guided navigational technology enhances accuracy and precision of the surgical procedure, minimises complications and facilitates surgery in challenging anatomical locations.


Subject(s)
Dental Implantation/methods , Surgery, Computer-Assisted , Female , Humans , Male , Safety
16.
Anal Chem ; 73(10): 2338-44, 2001 May 15.
Article in English | MEDLINE | ID: mdl-11393861

ABSTRACT

Single-particle mass spectrometers are now commonly used to analyze atmospheric particles and generate tens of thousands of spectra from typical measurement campaigns. The ART-2a spectrum algorithm has been used to classify these spectra. In this work, we generate a range of particles that are models of those that are common in the atmosphere. A single-particle mass spectrometer is used to analyze these known particles, and the spectra are classified using ART-2a. The optimum vigilance parameter is approximately 0.5 while the optimum learning rate is approximately 0.05. The classifications elucidate limitations in generation of test particles, their analysis by single-particle techniques, and their classification by ART-2a.

17.
J AAPOS ; 5(3): 139-42, 2001 Jun.
Article in English | MEDLINE | ID: mdl-11404738

ABSTRACT

PURPOSE: In children older than 18 months, primary probing procedures for congenital nasolacrimal duct obstruction (CNLDO) are thought to have lower rates of success. This study compares the results of primary probing to balloon dacryocystoplasty (DCP) in children stratified by age category. METHODS: In a retrospective chart review, 29 eyes with CNLDO that underwent balloon DCP in children older than 18 months were identified and age-matched to 29 eyes that underwent probing. The eyes were divided into 3 age categories: category 1 (18-24 months), category 2 (24-36 months), and category 3 (>36 months). RESULTS: Of the 29 eyes treated with balloon DCP (mean age, 37.1 months), 26 were successfully treated. Twenty-five of the 29 matched probed eyes (mean age, 31.1 months) were successfully treated, resulting in an overall success rate of 90% for balloon DCP and 86% for primary probing. Within each age category, the success rate varied but did not show an advantage to balloon DCP. The presence of crusting and expressible discharge from the puncta during preoperative evaluation predicted a successful probing (OR, 16; 95% CI, 1.3-192). CONCLUSION: Overall, balloon DCP did not appear to present an advantage as compared with primary probing as the initial treatment in these children. Primary probing has an impressive overall success rate that did not diminish in the children older than 36 months.


Subject(s)
Catheterization/methods , Dacryocystorhinostomy/methods , Lacrimal Duct Obstruction/congenital , Lacrimal Duct Obstruction/therapy , Nasolacrimal Duct , Child, Preschool , Humans , Infant , Retrospective Studies , Treatment Outcome
18.
J Appl Physiol (1985) ; 89(4): 1322-32, 2000 Oct.
Article in English | MEDLINE | ID: mdl-11007565

ABSTRACT

Fatigue is a major limitation to the clinical application of functional electrical stimulation. The activation pattern used during electrical stimulation affects force and fatigue. Identifying the activation pattern that produces the greatest force and least fatigue for each patient is, therefore, of great importance. Mathematical models that predict muscle forces and fatigue produced by a wide range of stimulation patterns would facilitate the search for optimal patterns. Previously, we developed a mathematical isometric force model that successfully identified the stimulation patterns that produced the greatest forces from healthy subjects under nonfatigue and fatigue conditions. The present study introduces a four-parameter fatigue model, coupled with the force model that predicts the fatigue induced by different stimulation patterns on different days during isometric contractions. This fatigue model accounted for 90% of the variability in forces produced by different fatigue tests. The predicted forces at the end of fatigue testing differed from those observed by only 9%. This model demonstrates the potential for predicting muscle fatigue in response to a wide range of stimulation patterns.


Subject(s)
Isometric Contraction/physiology , Models, Biological , Muscle Fatigue/physiology , Muscle, Skeletal/physiology , Electric Stimulation , Humans , Leg
19.
J Appl Physiol (1985) ; 89(1): 323-37, 2000 Jul.
Article in English | MEDLINE | ID: mdl-10904068

ABSTRACT

The human nasal cavity filters and conditions inspired air while providing olfactory function. Detailed experimental study of nasal airflow patterns has been limited because of the complex geometry of the nasal cavity. In this work, particle image velocimetry was used to determine two-dimensional instantaneous velocity vector fields in parallel planes throughout a model of the nasal cavity that was subjected to a nonoscillatory flow rate of 125 ml/s. The model, which was fabricated from 26 computed tomography scans by using rapid prototyping techniques, is a scaled replica of a human right nasal cavity. The resulting vector plots show that the flow is laminar and regions of highest velocity are in the nasal valve and in the inferior airway. The relatively low flow in the olfactory region appears to protect the olfactory bulb from particulate pollutants. Low flows were also observed in the nasal meatuses, whose primary function has been the subject of debate. Comparison of sequentially recorded data suggests a steady flow.


Subject(s)
Models, Biological , Nasal Cavity/anatomy & histology , Nasal Cavity/physiology , Respiration , Adult , Air Movements , Air Pollution , Airway Resistance/physiology , Humans , Male , Models, Anatomic , Olfactory Mucosa , Smell/physiology
20.
Toxicol Sci ; 54(1): 229-36, 2000 Mar.
Article in English | MEDLINE | ID: mdl-10746950

ABSTRACT

Aerosol dispersion and deposition are processes that occur concurrently in human airways. However, dispersion has not been properly accounted for in most deposition models. In this paper we have incorporated the latest understanding of dispersion into a dosimetry model and study the influence of dispersion on particle deposition in the lung. We show that dispersion influences the total deposition of inhaled particles and in particular increases the pulmonary deposition of fine mode particles. We also discuss how dispersion can help elucidate a number of clinical and epidemiologic results associated with particle deposition in the lung.


Subject(s)
Aerosols , Administration, Inhalation , Air Movements , Algorithms , Diffusion , Humans , Lung/metabolism , Models, Biological , Respiratory Mechanics/physiology
SELECTION OF CITATIONS
SEARCH DETAIL
...